Geant4 Modeling of Cellular Dosimetry of 188Re: Comparison between Geant4 Predicted Surviving Fraction and Experimentally Surviving Fraction Determined by MTT Assay

Background: The importance of cellular dosimetry in both diagnostic and radiation therapy is becoming increasingly recognized. Objective: This study aims to compare surviving fractions, which were predicted using Geant4 and contained three types of cancer cell lines exposed to 188Re with the experimentally surviving fraction determined by MTT assay. Material and Methods: In this comparative study, Geant4 was used to simulate the transport of electrons emitted by 188Re from the cell surface, cytoplasm, nucleus or medium around the cells. The nucleus dose per decay (S-value) was computed for models of single cell and random monolayer cell. Geant4-computed survival fraction (SF) of cancer cells exposed to 188Re was compared with the experimental SF values of MTT assay. Results: For single cell model, Geant4 S-values of nucleus-to-nucleus were consistent with values reported by Goddu et al. (ratio of S-values by analytical techniques vs. Geant4 = 0.811–0.975). Geant4 S-values of cytoplasm and cell surface to nucleus were relatively comparable to the reported values (ratio =0.914–1.21). For monolayer model, the values of SCy→N and SCS→N, were greater compared to those for model of single cell (2%–25% and 4%–38% were larger than single cell, respectively). The Geant4 predicted SF for monolayer MCF7, HeLa and A549 cells was in agreement with the experimental data in 10μCi activity (relative error of 2.29%, 2.69% and 2.99%, respectively). Conclusion: Geant4 simulation with monolayer cell model showed the highest accuracy in predicting the SF of cancer cells exposed to homogeneous distribution of 188Re in the medium.

[1]  Susanna Guatelli,et al.  Microdosimetry of electrons in liquid water using the low-energy models of Geant4 , 2017 .

[2]  R. Reilly,et al.  Monte Carlo N-Particle (MCNP) Modeling of the Cellular Dosimetry of 64Cu: Comparison with MIRDcell S Values and Implications for Studies of Its Cytotoxic Effects , 2017, The Journal of Nuclear Medicine.

[3]  S. Incerti,et al.  Calculation of cellular S-values using Geant4-DNA: The effect of cell geometry. , 2015, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[4]  X. Franceries,et al.  Nonlinearity in MCF7 Cell Survival Following Exposure to Modulated 6 MV Radiation Fields , 2015, Dose-response : a publication of International Hormesis Society.

[5]  Z. Ou,et al.  In vitro and in vivo studies on radiobiological effects of prolonged fraction delivery time in A549 cells , 2012, Journal of radiation research.

[6]  Sunil K Arya,et al.  Breast tumor cell detection at single cell resolution using an electrochemical impedance technique. , 2012, Lab on a chip.

[7]  D. Emfietzoglou,et al.  Monte Carlo single-cell dosimetry of I-131, I-125 and I-123 for targeted radioimmunotherapy of B-cell lymphoma , 2012, International journal of radiation biology.

[8]  Marzio De Napoli,et al.  Hadrontherapy: a Geant4-Based Tool for Proton/Ion-Therapy Studies , 2011 .

[9]  Uwe Oelfke,et al.  Radiobiological effect based treatment plan optimization with the linear quadratic model. , 2010, Zeitschrift fur medizinische Physik.

[10]  Jean-Philippe Pignol,et al.  Cellular Dosimetry of 111In Using Monte Carlo N-Particle Computer Code: Comparison with Analytic Methods and Correlation with In Vitro Cytotoxicity , 2010, Journal of Nuclear Medicine.

[11]  Ge Wang,et al.  Microarray analysis of DNA damage repair gene expression profiles in cervical cancer cells radioresistant to 252Cf neutron and X-rays , 2010, BMC Cancer.

[12]  Te-Wei Lee,et al.  In vivo examination of (188)Re(I)-tricarbonyl-labeled trastuzumab to target HER2-overexpressing breast cancer. , 2009, Nuclear medicine and biology.

[13]  M A Bernal,et al.  An investigation on the capabilities of the PENELOPE MC code in nanodosimetry. , 2009, Medical physics.

[14]  P. Hadjidoukas,et al.  A Monte Carlo study of absorbed dose distributions in both the vapor and liquid phases of water by intermediate energy electrons based on different condensed-history transport schemes , 2008, Physics in medicine and biology.

[15]  A. Sukstanskii,et al.  Intracellular water specific MR of microbead‐adherent cells: Hela cell intracellular water diffusion , 2008, Magnetic resonance in medicine.

[16]  Anirban Pathak,et al.  A Monte Carlo study of energy deposition at the sub-cellular level for application to targeted radionuclide therapy with low-energy electron emitters , 2007 .

[17]  P. Moretto,et al.  Models of biological effects of radiation in the Geant4 Toolkit , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[18]  Francis A. Cucinotta,et al.  Track-structure codes in radiation research , 2006 .

[19]  S. Incerti,et al.  Geant4 developments and applications , 2006, IEEE Transactions on Nuclear Science.

[20]  B. Fallone,et al.  Monte Carlo investigation of single cell beta dosimetry for intraperitoneal radionuclide therapy. , 2004, Physics in medicine and biology.

[21]  J. Chatal,et al.  Absorbed doses for internal radiotherapy from 22 beta-emitting radionuclides: beta dosimetry of small spheres. , 1994, Physics in medicine and biology.

[22]  J. Humm A microdosimetric model of astatine-211 labeled antibodies for radioimmunotherapy. , 1987, International journal of radiation oncology, biology, physics.

[23]  J L Humm,et al.  Dosimetric aspects of radiolabeled antibodies for tumor therapy. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[24]  Hong Shen,et al.  The morphometrical analysis on the ultrastructure of A549 cells. , 2010, Romanian journal of morphology and embryology = Revue roumaine de morphologie et embryologie.

[25]  Alan E. Nahum,et al.  The modified linear-quadratic model of Guerrero and Li can be derived from a mechanistic basis and exhibits linear-quadratic-linear behaviour , 2005 .

[26]  A. Dell'Acqua,et al.  Geant4—a simulation toolkit , 2003 .

[27]  V. Lewington,et al.  Radionuclide therapy. , 1999, Nuclear medicine communications.

[28]  T. Budinger,et al.  MIRD cellular S. values : self-absorbed dose per unit cumulated activity for selected radionuclides and monoenergetic electron and alpha particle emitters incorporated into different cell compartments , 1997 .