A spatially varying compton scatter correction for SPECT utilizing the integral Klein-Nishina cross section.

An algorithm correcting for the fraction of scattered events in SPECT and planar imaging is proposed. The algorithm utilizes a pixel-based multi-channel analyser for data acquisition. The method was designed to operate on a local level by three subtraction steps: (a) Subtracting a modified Klein-Nishina single scatter distribution, pixel by pixel, from the events obtained experimentally in the upper half of the photo-peak window. (b) Subtracting a mirrored distribution of the unscattered events hence obtained from that of total events in the lower half of the window, thus giving the scatter distribution in this part of the window. (c) Subtracting the sum of the scatter distributions in both window halves from the corresponding sum of total events in order to obtain the unscattered photons within the photo-peak window. The accuracy of the method was validated experimentally, using a new rCBF phantom allowing for imaging in matter corresponding to soft tissue and approximately in air, respectively. After correction for photon scattering and attenuation, the regional difference in SPECT values in soft tissue equivalent matter and in low-density matter (simulating air) was only 1.5 +/- 7.2% (mean +/- 1 SD), thus indicating a high accuracy of the correction method. Provided that an accurate and stable pixel peak-alignment routine is available, the method can be applied using a minimum of three windows.

[1]  L Thurfjell,et al.  CBA--an atlas-based software tool used to facilitate the interpretation of neuroimaging data. , 1995, Computer methods and programs in biomedicine.

[2]  Bernard Bendriem,et al.  Le spectre du rayonnement diffusé dans la fenêtre du photopic: analyse et proposition d'une méthode de correction , 1993 .

[3]  Matt A. King,et al.  A dual-photopeak window method for scatter correction. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  Lars Johansson,et al.  A novel phantom design for emission tomography enabling scatter- and attenuation-”free” single-photon emission tomography imaging , 2000, European Journal of Nuclear Medicine.

[5]  H Iida,et al.  Monte Carlo and experimental evaluation of accuracy and noise properties of two scatter correction methods for SPECT , 1996, Physics in medicine and biology.

[6]  E. Hoffman,et al.  3-D phantom to simulate cerebral blood flow and metabolic images for PET , 1990 .

[7]  C. Bohm,et al.  Correction for Scattered Radiation in a Ring Detector Positron Camera by Integral Transformation of the Projections , 1983, Journal of computer assisted tomography.

[8]  C E Floyd,et al.  Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigation. , 1984, Physics in medicine and biology.

[9]  Ronald J. Jaszczak,et al.  Scatter Compensation Techniques for SPECT , 1985, IEEE Transactions on Nuclear Science.

[11]  J. H. Hubbell,et al.  Mass energy-transfer and mass energy-absorption coefficients, including in-flight positron annihilation for photon energies 1 keV to 100 MeV , 1991 .

[12]  M. Ljungberg,et al.  A Monte Carlo program for the simulation of scintillation camera characteristics. , 1989, Computer methods and programs in biomedicine.

[13]  P. Pretorius,et al.  The channel ratio method of scatter correction for radionuclide image quantitation. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  P. Msaki,et al.  Subtraction of Compton-scattered photons in single-photon emission computerized tomography. , 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  S. Larsson,et al.  Generalized scatter correction method in SPECT using point scatter distribution functions. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[16]  Lee-Tzuu Chang,et al.  A Method for Attenuation Correction in Radionuclide Computed Tomography , 1978, IEEE Transactions on Nuclear Science.

[17]  K. Ogawa,et al.  A practical method for position-dependent Compton-scatter correction in single photon emission CT. , 1991, IEEE transactions on medical imaging.

[18]  K F Koral,et al.  SPECT Compton-scattering correction by analysis of energy spectra. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  R. Jaszczak,et al.  Improved SPECT quantification using compensation for scattered photons. , 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[20]  I Buvat,et al.  Comparative assessment of nine scatter correction methods based on spectral analysis using Monte Carlo simulations. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[21]  S. Larsson,et al.  Gamma camera emission tomography. Development and properties of a multi-sectional emission computed tomography system. , 1980, Acta radiologica. Supplementum.

[22]  Stig A. Larsson,et al.  Studies of a technique for attenuation correction in single photon emission computed tomography , 1987 .

[23]  M. Ingvar,et al.  Resting state rCBF mapping with single-photon emission tomography and positron emission tomography: magnitude and origin of differences , 1998, European Journal of Nuclear Medicine.

[24]  M Ljungberg,et al.  Attenuation correction in SPECT based on transmission studies and Monte Carlo simulations of build-up functions. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[25]  I Buvat,et al.  Target apex-seeking in factor analysis of medical image sequences. , 1993, Physics in medicine and biology.

[26]  J Mas,et al.  Scatter correction in planar imaging and SPECT by constrained factor analysis of dynamic structures (FADS). , 1990, Physics in Medicine and Biology.

[27]  Limitations of dual-photopeak window scatter correction for brain imaging. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.