Parallel Fourier domain optical coherence tomography: measurement of the human eye in vivo

We present an Optical coherence tomography (OCT) system which records full tomograms of in vivo eye structure in parallel. A full tomogram of 256(x) x 512(z) pixels covering a sample region of 6.7mm x 3,8mm is recorded in only 1ms. A standard Superluminescent diode (SLD) is used which results a depth resolution of 17 mm. Since neither depth nor transverse scanning is necessary, the system allows capturing full tomograms with high acquisition speed and reduced motion artifacts. To the best of our knowledge we present the first in vivo tomogram obtained with full parallel FD OCT system. In order to study cross talk issues for parallel illumination the transversal resolution for a thermal light source is compared to that with an SLD.

[1]  S H Yun,et al.  Motion artifacts in optical coherence tomography with frequency-domain ranging. , 2004, Optics express.

[2]  A. Fercher,et al.  Full range complex spectral optical coherence tomography technique in eye imaging. , 2002, Optics letters.

[3]  B. Bouma,et al.  Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. , 2003, Optics letters.

[4]  Teresa C. Chen,et al.  In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography. , 2004, Optics letters.

[5]  A. Fercher,et al.  Phase-shifting algorithm to achieve high-speed long-depth-range probing by frequency-domain optical coherence tomography. , 2003, Optics letters.

[6]  R. Zawadzki,et al.  Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography. , 2003, Optics express.

[7]  Harald Sattmann,et al.  A thermal light source technique for optical coherence tomography , 2000 .

[8]  Theo Lasser,et al.  Video-rate three-dimensional optical coherence tomography. , 2002, Optics express.

[9]  Adolf Friedrich Fercher,et al.  Three-dimensional ophthalmic optical coherence tomography with a refraction correction algorithm , 2003, European Conference on Biomedical Optics.

[10]  Maciej Wojtkowski,et al.  Complex spectral interferometry OCT , 1998, European Conference on Biomedical Optics.

[11]  R. Richards-Kortum,et al.  Spatially resolved spectral interferometry for determination of subsurface structure. , 1999, Optics letters.

[12]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[13]  W Drexler,et al.  Ultrahigh resolution Fourier domain optical coherence tomography. , 2004, Optics express.

[14]  H Saint-Jalmes,et al.  Full-field optical coherence microscopy. , 1998, Optics letters.

[15]  M. Wojtkowski,et al.  Real-time in vivo imaging by high-speed spectral optical coherence tomography. , 2003, Optics letters.

[16]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[17]  A. Fercher,et al.  Measurement of intraocular distances by backscattering spectral interferometry , 1995 .

[18]  R P Salathé,et al.  Spatially incoherent illumination as a mechanism for cross-talk suppression in wide-field optical coherence tomography. , 2004, Optics letters.