The Use of Partial Discharges as an Online Monitoring System for Underground Cable Joints

With their vast amount of joints, underground cable systems are expensive to maintain; therefore, measurement equipment must be cost-effective. This study proposes the long-term placement of partial-discharge (PD) monitoring units at cable joints. The unit consists of a peak detect circuit and a digital signal processor for acquiring and converting the sensors' PD signals into discharge sequence data, whose data are then provided to a remote computer for analysis and display of the condition of the cable joint. Finally, a cable joint with artificial defects was tested by accelerated aging tests to verify the performance of the equipment. Two characteristics, namely, the average discharge quantity (Qave) and the discharge phase region, are proposed and plotted against each other to render an evolution locus, which reveals a shape of an upside-down letter N. The locus allows a judgment to be made on the state of the insulation in the cable joint. These results further justify work to further develop the method as an online cable monitoring system.

[1]  N. Tongchim,et al.  Design and construction of a PC-based partial discharge analyzer using FPGA , 2000, 2000 TENCON Proceedings. Intelligent Systems and Technologies for the New Millennium (Cat. No.00CH37119).

[2]  Xie Hengkun,et al.  Study on wideband sensor of partial discharge for XLPE power cable , 2003, Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (Cat. No.03CH37417).

[3]  R. Schifani,et al.  Measurement of partial discharge in solid dielectrics with a microprocessor-based system , 1992 .

[4]  F. Guastavino,et al.  Tree growth monitoring by means of digital partial discharge measurements , 2003 .

[5]  H. Okubo,et al.  A novel technique for partial discharge and breakdown investigation based on current pulse waveform analysis , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  G.C. Stone,et al.  Partial discharge diagnostics and electrical equipment insulation condition assessment , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[7]  M. Leijon,et al.  Advances in online monitoring and localization of partial discharges in large rotating machines , 2004, IEEE Transactions on Energy Conversion.

[8]  Masayuki Hikita,et al.  Partial discharge characteristics till breakdown for XLPE cable joint with an artificial defect , 2003, Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (Cat. No.03CH37417).

[9]  P.L. Lewin,et al.  An improved optically based PD detection system for continuous on-line monitoring of HV cables , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  J. Zhu,et al.  The design of Rogowski coil with wide band using for partial discharge measurements , 2005, Proceedings of 2005 International Symposium on Electrical Insulating Materials, 2005. (ISEIM 2005)..

[11]  Don-Ha Hwang,et al.  Hybrid conversion scheme for digital measurement of partial discharge spectra , 2002, Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316).

[12]  Yu-Hsun Lin,et al.  Novel trend of "l" shape in PD pattern to judge the appropriate crucial moment of replacing cast-resin current transformer , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[13]  Wei Wei,et al.  Development of PD on-line monitoring system for large turbine generators , 2002, Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316).