Quality-by-Design III: Application of Near-Infrared Spectroscopy to Monitor Roller Compaction In-process and Product Quality Attributes of Immediate Release Tablets

The objective of this study is to use near-infrared spectroscopy (NIRS) coupled with multivariate chemometric models to monitor granule and tablet quality attributes in the formulation development and manufacturing of ciprofloxacin hydrochloride (CIP) immediate release tablets. Critical roller compaction process parameters, compression force (CFt), and formulation variables identified from our earlier studies were evaluated in more detail. Multivariate principal component analysis (PCA) and partial least square (PLS) models were developed during the development stage and used as a control tool to predict the quality of granules and tablets. Validated models were used to monitor and control batches manufactured at different sites to assess their robustness to change. The results showed that roll pressure (RP) and CFt played a critical role in the quality of the granules and the finished product within the range tested. Replacing binder source did not statistically influence the quality attributes of the granules and tablets. However, lubricant type has significantly impacted the granule size. Blend uniformity, crushing force, disintegration time during the manufacturing was predicted using validated PLS regression models with acceptable standard error of prediction (SEP) values, whereas the models resulted in higher SEP for batches obtained from different manufacturing site. From this study, we were able to identify critical factors which could impact the quality attributes of the CIP IR tablets. In summary, we demonstrated the ability of near-infrared spectroscopy coupled with chemometrics as a powerful tool to monitor critical quality attributes (CQA) identified during formulation development.

[1]  K. A. Khan,et al.  Effect of Re-Compression on the Properties of Tablets Prepared by Moist Granulation , 1983 .

[2]  R C Rowe,et al.  The effect of punch velocity on the compaction of a variety of materials , 1985, The Journal of pharmacy and pharmacology.

[3]  J. Remon,et al.  Roller compaction and tableting of microcrystalline cellulose/drug mixtures , 1998 .

[4]  Colleen E. Ruegger,et al.  The Effect of Compression and Decompression Speed on the Mechanical Strength of Compacts , 2000, Pharmaceutical development and technology.

[5]  K. Morris,et al.  Real-time near-infrared monitoring of content uniformity, moisture content, compact density, tensile strength, and Young's modulus of roller compacted powder blends. , 2005, Journal of pharmaceutical sciences.

[6]  K. Morris,et al.  Influence of ambient moisture on the compaction behavior of microcrystalline cellulose powder undergoing uni-axial compression and roller-compaction: a comparative study using near-infrared spectroscopy. , 2005, Journal of pharmaceutical sciences.

[7]  Changquan Calvin Sun,et al.  Reduced tabletability of roller compacted granules as a result of granule size enlargement. , 2006, Journal of pharmaceutical sciences.

[8]  F. Rinaldi,et al.  Effect of hydroxypropyl cellulose (HPC) on dissolution rate of hydrochlorothiazide tablets. , 2006, International journal of pharmaceutics.

[9]  P. Bertelsen,et al.  Improving the compaction properties of roller compacted calcium carbonate. , 2007, International journal of pharmaceutics.

[10]  K. Morris,et al.  Importance of Raw Material Attributes for Modeling Ribbon and Granule Properties in Roller Compaction: Multivariate Analysis on Roll Gap and NIR Spectral Slope as Process Critical Control Parameters , 2007, Journal of Pharmaceutical Innovation.

[11]  Investigation of Serrated Roll Surface Differences on Ribbon Thickness During Roller Compaction , 2007, Pharmaceutical development and technology.

[12]  R. Fahmy,et al.  Assessment of NIR spectroscopy for nondestructive analysis of physical and chemical attributes of sulfamethazine bolus dosage forms , 2005, AAPS PharmSciTech.

[13]  Stephen W Hoag,et al.  Quality by design, part I: application of NIR spectroscopy to monitor tablet manufacturing process. , 2008, Journal of pharmaceutical sciences.

[14]  Stephen W Hoag,et al.  Quality by design, part II: application of NIR spectroscopy to monitor the coating process for a pharmaceutical sustained release product. , 2008, Journal of pharmaceutical sciences.

[15]  Hong Wen,et al.  Systematical approach of formulation and process development using roller compaction. , 2009, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[16]  Stuart L. Cantor,et al.  NIR Spectroscopy Applications in the Development of a Compacted Multiparticulate System for Modified Release , 2011, AAPS PharmSciTech.

[17]  D. Barends,et al.  Biowaiver monographs for immediate release solid oral dosage forms: ciprofloxacin hydrochloride. , 2011, Journal of pharmaceutical sciences.

[18]  Vivek S. Dave,et al.  Assessment of the critical factors affecting the porosity of roller compacted ribbons and the feasibility of using NIR chemical imaging to evaluate the porosity distribution. , 2011, International journal of pharmaceutics.

[19]  Ravikanth Kona,et al.  Quality by Design I: Application of Failure Mode Effect Analysis (FMEA) and Plackett–Burman Design of Experiments in the Identification of “Main Factors” in the Formulation and Process Design Space for Roller-Compacted Ciprofloxacin Hydrochloride Immediate-Release Tablets , 2012, AAPS PharmSciTech.

[20]  R. Fahmy,et al.  Eudragit® RS PO/RL PO as rate-controlling matrix-formers via roller compaction: Influence of formulation and process variables on functional attributes of granules and tablets , 2012, Drug development and industrial pharmacy.

[21]  Stephen W. Hoag,et al.  Quality-by-Design II: Application of Quantitative Risk Analysis to the Formulation of Ciprofloxacin Tablets , 2015, AAPS PharmSciTech.