Subcoronary Ross procedure in patients with active endocarditis.

BACKGROUND The Ross procedure has gained increasing interest as an attractive alternative to a prosthetic aortic valve substitute within the last decade. Because of a probably better resistance to infection as one of its advantages, the pulmonary autograft is theoretically preferable for active endocarditis. METHODS Between June 1994 and July 2003, the Ross procedure was performed using the subcoronary and inclusion technique in 296 patients (231 male, 65 female). Twenty patients had an active endocarditis of the aortic valve at the time of operation. A bicuspid valve was present in 10 patients. One patient had previous aortic valve surgery. Clinical and echocardiographic follow-up was complete. RESULTS Early mortality was 1, late mortality was 0. There were no recurrence of endocarditis and no neurologic events during the mean follow-up of 47.3 +/- 28.6 months. All patients were in New York Heart Association class I. Mean and maximum pressure gradient across the autograft was 3.5 +/- 2.0 and 6.5 +/- 3.4, respectively, with no autograft insufficiency in 15, 1+ in 4. Comparing postoperative with the last investigations, there were no significant changes of pressure gradients or grade of regurgitation. Mean and maximum homograft pressure gradients were 7.9 +/- 3.7 and 16.2 +/- 8.1 mm Hg, respectively, at last investigation; most patients had no or mild homograft regurgitation (0+, n = 13; 1+, n = 5; 2+, n = 1). CONCLUSIONS Native valve endocarditis can be treated with excellent results using the Ross procedure with the subcoronary and inclusion technique, with low mortality and morbidity rates and a very low recurrence rate of endocarditis.

[1]  K. Chandrasekaran,et al.  , endocarditis Advantage of autograft and homograft valve replacement for complex aortic valve , 1999 .

[2]  S. Langley,et al.  Surgery for active culture-positive endocarditis: determinants of early and late outcome. , 2000, The Annals of thoracic surgery.

[3]  J. Aagaard,et al.  Acute endocarditis treated with radical debridement and implantation of mechanical or stented bioprosthetic devices. , 2001, The Annals of thoracic surgery.

[4]  R. Lange,et al.  Surgical treatment of acute endocarditis of the aortic valve with paravalvular abscess: considerations justifying the use of mechanical replacement devices. , 1996, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[5]  C. Otto,et al.  Recommendations for quantification of Doppler echocardiography: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. , 2002, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[6]  A. Prat,et al.  Ross operation for active culture-positive aortic valve endocarditis with extensive paravalvular involvement. , 2001, The Annals of thoracic surgery.

[7]  H. Sievers,et al.  Midterm Results of the Ross Procedure Preserving the Patient’s Aortic Root , 2003, Circulation.

[8]  G. Pettersson,et al.  Treatment of aortic valve endocarditis with the Ross operation. , 1998, European Journal of Cardio-Thoracic Surgery.

[9]  B. Lytle,et al.  Early onset prosthetic valve endocarditis: the Cleveland Clinic experience 1992-1997. , 2000, The Annals of thoracic surgery.

[10]  D. Durack,et al.  New criteria for diagnosis of infective endocarditis: utilization of specific echocardiographic findings. Duke Endocarditis Service. , 1994, The American journal of medicine.

[11]  A. Berrebi,et al.  Cryopreserved aortic viable homograft for active aortic endocarditis. , 2005, The Annals of thoracic surgery.

[12]  Y. D'udekem,et al.  Long-term results of surgery for active infective endocarditis. , 1997, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[13]  D. McGiffin,et al.  Aortic valve infection. Risk factors for death and recurrent endocarditis after aortic valve replacement. , 1992, The Journal of thoracic and cardiovascular surgery.

[14]  T. Carrel,et al.  Infective endocarditis: determinants of long term outcome , 2002, Heart.

[15]  R. S. Mitchell,et al.  Treatment of endocarditis with valve replacement: the question of tissue versus mechanical prosthesis. , 2001, The Annals of thoracic surgery.

[16]  C. Doré,et al.  Thirty-day mortality and long-term survival following surgery for prosthetic endocarditis: a study from the UK heart valve registry. , 1998, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[17]  D. Campbell,et al.  Degeneration of aortic valve allografts in young recipients. , 1993, The Journal of thoracic and cardiovascular surgery.

[18]  L. V. von Segesser,et al.  Emergency surgery for acute infective aortic valve endocarditis: performance of cryopreserved homografts and mode of failure. , 1997, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[19]  F. Alla,et al.  Changing profile of infective endocarditis: results of a 1-year survey in France. , 2002, JAMA.