Natural Ventilation of Indoor Air Temperature: A Case Study of the Traditional Malay House in Penang

Problem statement: It was the aim of the study to analyze the level o f performance of natural air ventilation with a case study of the tr aditional Malay house in Penang, Malaysia. This stu dy provided information on the architectural design in relation to natural air ventilation. It promoted passive design in contrast to most housing design w hich has poor natural air ventilation because the design was orientated to energy consumption that sl ightly more than one third of the electric energy was used for heating, ventilating and air condition ing systems. Approach: This analysis used quantitative method which measured temperature, humidity and wind speed of the traditional house. The result indicated the level of performance of cr oss air ventilation and stack effect. Results: The analysis showed that the traditional house has a de sign integrated with natural air ventilation system . The indoor house temperature and relative humidity had slightly lower than its outdoor area. However, the indoor area had lower wind speed level than the outdoor area. Conclusion : The study showed that maximum openings on the building walls created high air intakes outside the house to give poor performance of stack effect. The design had more emphasis to cross air ventilation.

[1]  Haralambos Sarimveis,et al.  Development of a computational tool to quantify architectural-design effects on thermal comfort in naturally ventilated rural houses , 2010 .

[2]  Abdul Rahman Housing design in relation to environmental comfort , 1995 .

[3]  N. Carslaw A new detailed chemical model for indoor air pollution , 2007 .

[4]  N. Wong,et al.  Thermal comfort for naturally ventilated houses in Indonesia , 2004 .

[5]  Wang Liping,et al.  Applying Natural Ventilation for Thermal Comfort in Residential Buildings in Singapore , 2007 .

[6]  Manoj Kumar Singh,et al.  Thermal performance study and evaluation of comfort temperatures in vernacular buildings of North-East India , 2010 .

[7]  Abdeen Mustafa Omer,et al.  Renewable building energy systems and passive human comfort solutions , 2008 .

[8]  Raymond E. Crist,et al.  Land, People and Economy in Malaya , 1964 .

[9]  François Michaud,et al.  A new predictive thermal sensation index of human response , 1999 .

[10]  Y. Nishi,et al.  Chapter 2 Measurement of Thermal Balance of Man , 1981 .

[11]  Peder Wolkoff,et al.  The dichotomy of relative humidity on indoor air quality. , 2007, Environment international.

[12]  Bob Fox,et al.  Hazardous Building Materials: A Guide to the Selection of Environmentally Responsible Alternatives , 2002 .

[13]  Anton Maas Experimental and Theoretical Case Study on Cross Ventilation – designing a mathematical model , .

[14]  G. Z. Brown,et al.  Sun, Wind and Light: Architectural Design Strategies , 1985 .

[15]  Phillip Gibbs,et al.  Building a Malay house , 1987 .

[16]  Ken Yeang Ecodesign: A Manual for Ecological Design , 2006 .

[17]  Michele G. Melaragno,et al.  Wind in architectural and environmental design , 1982 .

[18]  Daniel D. Chiras,et al.  The Solar House: Passive Heating and Cooling , 2002 .

[19]  John H Klote,et al.  A general routine analysis of stack effect , 1991 .