Novel Direct Current-Space-Vector Control for shunt active power filters based on three-Level inverters

The permanently growing number of electric drives with non-sinusoidal line currents has given increased interest in active power filters (APF), to avoid grid problems caused by harmonic distortions. In this paper, a novel direct current-space-vector control scheme (DCSVC) is presented for a three-level, neutral- point-clamped voltage-source inverter, which is employed as an active power filter. The proposed method works in the time domain, generating the equivalent ohmic conductance indirectly by means of the dc-link voltage control of the APF. Based on the Fast Fourier Transform (FFT) the compensation of the reactive fundamental current can be cancelled, confining the operation to only harmonic compensation and thus saving the APF's apparent power. The novel direct current-space-vector controller, operating in synchronously rotating coordinates is implemented in a field programmed gate array (FPGA), realizing the switching states from switching tables. The proposed control reduces the average switching frequency and thus, the switching power loss significantly, compared with a previous direct current-space-vector control, operating in stationary coordinates. Simulation and experimental results validate the feasibility and highly dynamic performance of the proposed control, both for harmonic and total non-active current compensation.

[1]  F. Blaabjerg,et al.  High Performance Current Controller for Selective Harmonic Compensation in Active Power Filters , 2007, IEEE Transactions on Power Electronics.

[2]  Bong-Hwan Kwon,et al.  A novel SVM-based hysteresis current controller , 1998 .

[3]  J. Allmeling,et al.  A control structure for fast harmonics compensation in active filters , 2004, IEEE Transactions on Power Electronics.

[4]  F. Blaabjerg,et al.  Evaluation of harmonic detection methods for active power filter applications , 2005, Twentieth Annual IEEE Applied Power Electronics Conference and Exposition, 2005. APEC 2005..

[5]  Hirofumi Akagi,et al.  Active Harmonic Filters , 2005, Proceedings of the IEEE.

[6]  M. Sonnenschein,et al.  Comparison of time‐domain and frequency‐domain control schemes for shunt active filters , 1999 .

[7]  M. A. Dzieniakowski,et al.  Novel space vector based current controllers for PWM-inverters , 1989, 20th Annual IEEE Power Electronics Specialists Conference.

[8]  Juan Dixon,et al.  Voltage-source active power filter based on multilevel converter and ultracapacitor DC link , 2006, IEEE Transactions on Industrial Electronics.

[9]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[10]  Subhashish Bhattacharya,et al.  Active filter system implementation , 1998 .

[11]  M. Depenbrock The FBD-method, a generally applicable tool for analyzing power relations , 1993 .

[12]  M. Salo,et al.  Comparison of Voltage-Source and Current-Source Shunt Active Power Filters , 2005, IEEE Transactions on Power Electronics.

[13]  B. Bose An adaptive hysteresis-band current control technique of a voltage-fed PWM inverter for machine drive system , 1990 .

[14]  Wang Zhaoan,et al.  Study on the Influence of Supply-Voltage Fluctuation on Shunt Active Power Filter , 2007, IEEE Transactions on Power Delivery.

[15]  Dianguo Xu,et al.  A Novel Design Method of LCL Type Utility Interface for Three-Phase Voltage Source Rectifier , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.