Virtual Sensors for Advanced Controllers in Rehabilitation Robotics

In order to properly control rehabilitation robotic devices, the measurement of interaction force and motion between patient and robot is an essential part. Usually, however, this is a complex task that requires the use of accurate sensors which increase the cost and the complexity of the robotic device. In this work, we address the development of virtual sensors that can be used as an alternative of actual force and motion sensors for the Universal Haptic Pantograph (UHP) rehabilitation robot for upper limbs training. These virtual sensors estimate the force and motion at the contact point where the patient interacts with the robot using the mathematical model of the robotic device and measurement through low cost position sensors. To demonstrate the performance of the proposed virtual sensors, they have been implemented in an advanced position/force controller of the UHP rehabilitation robot and experimentally evaluated. The experimental results reveal that the controller based on the virtual sensors has similar performance to the one using direct measurement (less than 0.005 m and 1.5 N difference in mean error). Hence, the developed virtual sensors to estimate interaction force and motion can be adopted to replace actual precise but normally high-priced sensors which are fundamental components for advanced control of rehabilitation robotic devices.

[1]  Dan Zhang,et al.  Design and Optimization of a Hybrid-Driven Waist Rehabilitation Robot , 2016, Sensors.

[2]  Wei Meng,et al.  Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation , 2015 .

[3]  Aiguo Song,et al.  Adaptive motion control of arm rehabilitation robot based on impedance identification , 2014, Robotica.

[4]  Bram Vanderborght,et al.  Multi-Axis Force Sensor for Human–Robot Interaction Sensing in a Rehabilitation Robotic Device , 2017, Sensors.

[5]  Jinung An,et al.  Force Sensorless Multi-functional Impedance Control for Rehabilitation Robot , 2017 .

[6]  Asier Zubizarreta,et al.  Kinematic and Dynamic Modeling of a Multifunctional Rehabilitation Robot UHP , 2016 .

[7]  Asier Zubizarreta,et al.  Kinematical and dynamical modeling of a multipurpose upper limbs rehabilitation robot , 2018 .

[8]  Heping Chen,et al.  Robotic assembly automation using robust compliant control , 2013 .

[9]  C. V. van Heugten,et al.  The economic impact of stroke in The Netherlands: the €-restore4stroke study , 2012, BMC Public Health.

[10]  Shuxiang Guo,et al.  Design of a Novel Telerehabilitation System with a Force-Sensing Mechanism , 2015, Sensors.

[11]  Matthew M. Williamson,et al.  Series elastic actuators , 1995, Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots.

[12]  Toshio Fukuda,et al.  State of the Art: Bipedal Robots for Lower Limb Rehabilitation , 2017 .

[13]  H. A. Talebi,et al.  A robust force observer for robot manipulators subjected to external disturbance , 2015, 2015 3rd RSI International Conference on Robotics and Mechatronics (ICROM).

[14]  Shuguo Wang,et al.  Design and development of a hand exoskeleton for rehabilitation of hand injuries , 2014 .

[15]  Maarouf Saad,et al.  Virtual decomposition control of an exoskeleton robot arm , 2014, Robotica.

[16]  Stefano Rossi,et al.  Robotic and clinical evaluation of upper limb motor performance in patients with Friedreich’s Ataxia: an observational study , 2015, Journal of NeuroEngineering and Rehabilitation.

[17]  Alicia Casals,et al.  Sensorless force estimation using a neuro-vision-based approach for robotic-assisted surgery , 2015, 2015 7th International IEEE/EMBS Conference on Neural Engineering (NER).

[18]  Rafael Raya,et al.  Emerging Therapies in Neurorehabilitation II , 2015 .

[19]  Alan D. Lopez,et al.  The Global Burden of Disease Study , 2003 .

[20]  V. Feigin,et al.  Global and regional burden of stroke during 1990–2010: findings from the Global Burden of Disease Study 2010 , 2014, The Lancet.

[21]  Thierry Keller,et al.  Variable structure pantograph mechanism with spring suspension system for comprehensive upper-limb haptic movement training. , 2011, Journal of rehabilitation research and development.

[22]  Wenjun Xu,et al.  Sensorless and adaptive admittance control of industrial robot in physical human−robot interaction , 2018, Robotics and Computer-Integrated Manufacturing.

[23]  Alessandro De Luca,et al.  Sensorless Robot Collision Detection and Hybrid Force/Motion Control , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[24]  Aldo Rossi,et al.  On the Use of Cable-Driven Robots in Early Inpatient Stroke Rehabilitation , 2017 .

[25]  Shane S. Q. Xie,et al.  Advanced Robotics for Medical Rehabilitation - Current State of the Art and Recent Advances , 2015, Springer Tracts in Advanced Robotics.

[26]  Agnes Roby-Brami,et al.  Upper-Limb Robotic Exoskeletons for Neurorehabilitation: A Review on Control Strategies , 2016, IEEE Reviews in Biomedical Engineering.

[27]  Hsiao-Ting Tseng,et al.  Predicting rehabilitation treatment helpfulness to stroke patients: A supervised learning approach , 2017, Artif. Intell. Res..

[28]  Baoliang Zhao,et al.  Sensorless Force Sensing for Minimally Invasive Surgery. , 2015, Journal of medical devices.

[29]  Li-Chen Fu,et al.  Active control with force sensor and shoulder circumduction implemented on exoskeleton robot NTUH-II , 2016, 2016 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[30]  Aiguo Song,et al.  A Novel Human-Robot Cooperative Method for Upper Extremity Rehabilitation , 2017, Int. J. Soc. Robotics.

[31]  Ying Tan,et al.  Learning control in robot-assisted rehabilitation of motor skills - a review , 2016, J. Control. Decis..