Aging of Class-B Insulating Material in Nitrogen
暂无分享,去创建一个
New studies have been made of the aging of Class-B insulating material in nitrogen, and it has been found that the insulations follow the same behavior rules in nitrogen as they do in air. However, the tests indicate Class-B material in nitrogen can be used in temperatures where the more expensive Class-H insulations were formerly used.
[1] L. C. Whitman,et al. Aging of dry-type transformer insulation , 1949, Electrical Engineering.
[2] Aiee Transformer Subcommittee. Preliminary Report on Laboratory Aging Tests on Class A Insulation , 1947 .