On the influence of aspect ratio and distributor in gas fluidized beds

Abstract The influence of distributor on the uniformity of fluidization and the selection of the aspect ratio at a critical fluidization quality which corresponds to the maximum of the experimental to theoretical bed pressure drop ratio have been studied. Two types of multi-orifice distributors and three bed materials having their particle size in the range 70–161 μm have been investigated in an air fluidized bed at ambient conditions. The distributor to bed pressure drop ratio and the operating velocity for achieving uniform fluidization have been analyzed. The aspect ratio is shown to have a significant role in selecting a distributor and fixing the operating velocity particularly when the bed is shallow. A model equation derived from the first principles is proposed to predict the distributor to bed pressure drop ratio in terms of the critical aspect ratio and compared with the data reported in the literature.

[1]  A. Vogelpohl,et al.  On the Distributors and Design Criteria for Gas-Solid and, Gas-Liquid-Solid Fluidized Beds , 1993 .

[2]  Ahmed O. Hassan,et al.  Gas distribution in shallow packed beds , 1993 .

[3]  D. Sathiyamoorthy,et al.  The choice of distributor to bed pressure drop ratio in gas fluidised beds , 1981 .

[4]  Ch. Sridhar Rao,et al.  Multi-orifice plate distributors in gas fluidised beds — a model for design of distributors , 1979 .

[5]  A. E. Qureshi,et al.  Fluidised bed gas distributors , 1979 .

[6]  Derek Geldart,et al.  The design of distributors for gas-fluidized beds , 1985 .

[7]  Dakshinamoorthy Sathiyamoorthy,et al.  Gas distributor in fluidised beds , 1978 .

[8]  R. Jackson,et al.  The nature of aggregative and particulate fluidization , 1964 .

[9]  J. Baeyens,et al.  Fluid-bed heat transfer : By J. S. M. BOTTERILL, Academic Press, London, 1975; pp. xvi + 299; illustrated; £9.00 net. , 1976 .

[10]  R. Jackson,et al.  Fluid Mechanical Description of Fluidized Beds. The Effect of Distributor Thickness on Convective Instabilities , 1975 .

[11]  U. P. Ganguly,et al.  Effect of aspect ratio on bed expansion in pirticulate fluidization , 1985 .

[12]  R. Siegel Effect of distributor plate‐to‐bed resistance ratio on onset of fluidized‐bed channeling , 1976 .

[13]  Masayuki Horio,et al.  GAS MOTION AND BUBBLE FORMATION AT THE DISTRIBUTOR OF A FLUIDIZED BED , 1990 .

[14]  D. R. Richardson HOW TO DESIGN FLUID-FLOW DISTRIBUTORS , 1961 .

[15]  A. Baskakov,et al.  Uniformity of fluidization on a multi‐orifice gas distributor , 1985 .

[16]  Chien-Song Chyang,et al.  Pressure Drop across a Perforated-Plate Distributor in a Gas-Fluidized Bed , 1991 .

[17]  C. Raghavendra Rao,et al.  Effect of distributors on heat transfer from immersed surfaces in gas fluidised beds , 1988 .

[18]  C. Y. Wen,et al.  Estimation of bubble diameter in gaseous fluidized beds , 1975 .