A three-step reconstruction method for fluorescence molecular tomography based on compressive sensing

Fluorescence molecular tomography (FMT) is a promising tool for real time in vivo quantification of neurotransmission (NT) as we pursue in our BRAIN initiative effort. However, the acquired image data are noisy and the reconstruction problem is ill-posed. Further, while spatial sparsity of the NT effects could be exploited, traditional compressive-sensing methods cannot be directly applied as the system matrix in FMT is highly coherent. To overcome these issues, we propose and assess a three-step reconstruction method. First, truncated singular value decomposition is applied on the data to reduce matrix coherence. The resultant image data are input to a homotopy-based reconstruction strategy that exploits sparsity via ℓ1 regularization. The reconstructed image is then input to a maximum-likelihood expectation maximization (MLEM) algorithm that retains the sparseness of the input estimate and improves upon the quantitation by accurate Poisson noise modeling. The proposed reconstruction method was evaluated in a three-dimensional simulated setup with fluorescent sources in a cuboidal scattering medium with optical properties simulating human brain cortex (reduced scattering coefficient: 9.2 cm−1, absorption coefficient: 0.1 cm−1 and tomographic measurements made using pixelated detectors. In different experiments, fluorescent sources of varying size and intensity were simulated. The proposed reconstruction method provided accurate estimates of the fluorescent source intensity, with a 20% lower root mean square error on average compared to the pure-homotopy method for all considered source intensities and sizes. Further, compared with conventional ℓ2 regularized algorithm, overall, the proposed method reconstructed substantially more accurate fluorescence distribution. The proposed method shows considerable promise and will be tested using more realistic simulations and experimental setups.

[1]  B. Pogue,et al.  Image-guided diffuse optical fluorescence tomography implemented with Laplacian-type regularization. , 2007, Optics express.

[3]  R. Tibshirani,et al.  Least angle regression , 2004, math/0406456.

[4]  Xavier Intes,et al.  Comparison of Monte Carlo methods for fluorescence molecular tomography-computational efficiency. , 2011, Medical physics.

[5]  David A Boas,et al.  Monte Carlo simulation of photon migration in 3D turbid media accelerated by graphics processing units. , 2009, Optics express.

[6]  Yaakov Tsaig,et al.  Fast Solution of $\ell _{1}$ -Norm Minimization Problems When the Solution May Be Sparse , 2008, IEEE Transactions on Information Theory.

[7]  Trevor Hastie,et al.  Regularization Paths for Generalized Linear Models via Coordinate Descent. , 2010, Journal of statistical software.

[8]  Vasilis Ntziachristos,et al.  Looking and listening to light: the evolution of whole-body photonic imaging , 2005, Nature Biotechnology.

[9]  Ali Adibi,et al.  Total variation regularization for 3D reconstruction in fluorescence tomography: experimental phantom studies. , 2012, Applied optics.

[10]  Vasilis Ntziachristos,et al.  Tomographic fluorescence imaging of tumor vascular volume in mice. , 2007, Radiology.

[11]  Joel A. Tropp,et al.  Signal Recovery From Random Measurements Via Orthogonal Matching Pursuit , 2007, IEEE Transactions on Information Theory.

[12]  Eric Clarkson,et al.  An ideal-observer framework to investigate signal detectability in diffuse optical imaging. , 2013, Biomedical optics express.

[13]  Melanie Grunwald,et al.  Foundations Of Image Science , 2016 .

[14]  Vasilis Ntziachristos,et al.  Fluorescence Molecular Tomography Based on A Priori Information , 2006 .

[15]  Eric Clarkson,et al.  Simulating photon-transport in uniform media using the radiative transport equation: a study using the Neumann-series approach. , 2012, Journal of the Optical Society of America. A, Optics, image science, and vision.

[16]  Jie Tian,et al.  Adaptive regularized method based on homotopy for sparse fluorescence tomography. , 2013, Applied optics.

[17]  Abhinav K. Jha,et al.  A radiative transfer equation-based image-reconstruction method incorporating boundary conditions for diffuse optical imaging , 2017, Medical Imaging.

[18]  Eric Clarkson,et al.  Three-dimensional Neumann-series approach to model light transport in nonuniform media. , 2012, Journal of the Optical Society of America. A, Optics, image science, and vision.

[19]  Jianwen Luo,et al.  Greedy reconstruction algorithm for fluorescence molecular tomography by means of truncated singular value decomposition conversion. , 2013, Journal of the Optical Society of America. A, Optics, image science, and vision.