Intimal hyperplasia and wall shear in arterial bypass graft distal anastomoses: an in vivo model study.

The observation of intimal hyperplasia at bypass graft anastomoses has suggested a potential interaction between local hemodynamics and vascular wall response. Wall shear has been particularly implicated because of its known effects upon the endothelium of normal vessels and, thus, was examined as to its possible role in the development of intimal hyperplasia in arterial bypass graft distal anastomoses. Tapered (4-7 mm I.D.) e-PTFE synthetic grafts 6 cm long were placed as bilateral carotid artery bypasses in six adult, mongrel dogs weighing between 25 and 30 kg with distal anastomotic graft-to-artery diameter ratios (DR) of either 1.0 or 1.5. Immediately following implantation, simultaneous axial velocity measurements were made in the toe and artery floor regions in the plane of the anastomosis at radial increments of 0.35 mm, 0.70 mm, and 1.05 mm using a specially designed 20 MHz triple crystal ultrasonic wall shear rate transducer Mean, peak, and pulse amplitude wall shear rates (WSRs), their absolute values, the spatial and temporal wall shear stress gradients (WSSG), and the oscillatory shear index (OSI) were computed from these velocity measurements. All grafts were harvested after 12 weeks implantation and measurements of the degree of intimal hyperplasia (IH) were made along the toe region and the artery floor of the host artery in 1 mm increments. While some IH occurred along the toe region (8.35+/-23.1 microm) and was significantly different between DR groups (p<0.003), the greatest amount occurred along the artery floor (81.6+/-106.5 microm, mean +/- S.D.) (p < 0.001) although no significant differences were found between DR groups. Linear regressions were performed on the paired IH and mean, peak, and pulse amplitude WSR data as well as the absolute mean, peak, and pulse amplitude WSR data from all grafts. The mean and absolute mean WSRs showed a modest correlation with IH (r = -0.406 and -0.370, respectively) with further improvements seen (r = -0.482 and -0.445, respectively) when using an exponential relationship. The overall best correlation was seen against an exponential function of the OSI (r = 0.600). Although these correlation coefficients were not high, they were found to be statistically significant as evidenced by the large F-statistic obtained. Finally, it was observed that over 75 percent of the IH occurred at or below a mean WSR value of 100 s(-1) while approximately 92 percent of the IH occurred at or below a mean WSR equal to one-half that of the native artery. Therefore, while not being the only factor involved, wall shear (and in particular, oscillators wall shear) appears to provide a stimulus for the development of anastomotic intimal hyperplasia.

[1]  J D Thomas,et al.  The effect of angle and flow rate upon hemodynamics in distal vascular graft anastomoses: a numerical model study. , 1991, Journal of biomechanical engineering.

[2]  D. Ku,et al.  Pulsatile Flow and Atherosclerosis in the Human Carotid Bifurcation: Positive Correlation between Plaque Location and Low and Oscillating Shear Stress , 1985, Arteriosclerosis.

[3]  Models of side-to-end anastomoses: effects of angle and flow split. , 1982, The Journal of surgical research.

[4]  A. Gown,et al.  Mechanisms of arterial graft failure. 1. Role of cellular proliferation in early healing of PTFE prostheses. , 1985, The American journal of pathology.

[5]  ROBERT M. NEREM,et al.  Velocity Distribution and Intimal Proliferation in Autologous Vein Grafts in Dogs , 1978, Circulation research.

[6]  S Glagov,et al.  Anastomotic intimal hyperplasia: mechanical injury or flow induced. , 1992, Journal of vascular surgery.

[7]  D. E. Szilagyi,et al.  Biologic Fate of Autogenous Vein lmplants as Arterial Substitutes: Clinical, Angiographic and Histopathologic Observations in Femoro‐Popliteal Operations for Atherosc erosis , 1973, Annals of surgery.

[8]  Clowes Aw,et al.  The influence of hypertension on injury-induced myointimal thickening. , 1980 .

[9]  W. Moore,et al.  An overview of intimal hyperplasia. , 1990, Surgery, gynecology & obstetrics.

[10]  A. Callow History of vascular graft development , 1986 .

[11]  P. Dobrin,et al.  Mechanical factors predisposing to intimal hyperplasia and medial thickening in autogenous vein grafts. , 1989, Surgery.

[12]  W. Quist,et al.  Flow disturbance at the distal end-to-side anastomosis. Effect of patency of the proximal outflow segment and angle of anastomosis. , 1980, Archives of surgery.

[13]  D. Ku,et al.  Optimal graft diameter: effect of wall shear stress on vascular healing. , 1989, Journal of vascular surgery.

[14]  R. Keynton,et al.  The effect of graft caliber upon wall shear within in vivo distal vascular anastomoses. , 1999, Journal of Biomechanical Engineering.

[15]  M Ojha,et al.  Spatial and temporal variations of wall shear stress within an end-to-side arterial anastomosis model. , 1993, Journal of biomechanics.

[16]  D. Hayoz,et al.  Influence of oscillatory and unidirectional flow environments on the expression of endothelin and nitric oxide synthase in cultured endothelial cells. , 1998, Arteriosclerosis, thrombosis, and vascular biology.

[17]  J. Ando,et al.  Wall shear stress rather than shear rate regulates cytoplasmic Ca++ responses to flow in vascular endothelial cells. , 1993, Biochemical and biophysical research communications.

[18]  A. Clowes,et al.  Mechanisms of arterial graft failure. II. Chronic endothelial and smooth muscle cell proliferation in healing polytetrafluoroethylene prostheses. , 1986, Journal of vascular surgery.

[19]  D. Steinman,et al.  A numerical simulation of flow in a two-dimensional end-to-side anastomosis model. , 1993, Journal of biomechanical engineering.

[20]  R. Keynton,et al.  Design, fabrication, and in vitro evaluation of an in vivo ultrasonic Doppler wall shear rate measuring device , 1995, IEEE Transactions on Biomedical Engineering.

[21]  D. Ku,et al.  Pulsatile flow in the human left coronary artery bifurcation: average conditions. , 1996, Journal of biomechanical engineering.

[22]  M. Adams,et al.  Kinetics of vein graft hyperplasia: association with tangential stress. , 1987, Journal of vascular surgery.

[23]  G. Seabrook,et al.  Hemodynamics of vein graft stenosis. , 1988, Journal of vascular surgery.

[24]  A. Clowes,et al.  Acute reductions in blood flow and shear stress induce platelet-derived growth factor-A expression in baboon prosthetic grafts. , 1996, Circulation research.

[25]  F. Veith,et al.  Management of early and late thrombosis of expanded polytetrafluoroethylene (PTFE) femoropopliteal bypass grafts: favorable prognosis with appropriate reoperation. , 1980, Surgery.

[26]  S Glagov,et al.  Hemodynamic patterns in two models of end-to-side vascular graft anastomoses: effects of pulsatility, flow division, Reynolds number, and hood length. , 1993, Journal of biomechanical engineering.

[27]  S. Diamond,et al.  Fluid flow decreases preproendothelin mRNA levels and suppresses endothelin-1 peptide release in cultured human endothelial cells. , 1991, Journal of vascular surgery.

[28]  W. Quist,et al.  A Mechanism of Failure in Dacron(r) Arterial Grafts , 1983 .

[29]  M. Ojha Wall shear stress temporal gradient and anastomotic intimal hyperplasia. , 1994, Circulation research.

[30]  I. Dardik,et al.  Distal arteriovenous fistula as an adjunct to maintaining arterial and graft patency for limb salvage. , 1983, Surgery.

[31]  M. Bond,et al.  Intimal changes in arteriovenous bypass grafts. Effects of varying the angle of implantation at the proximal anastomosis and of producing stenosis in the distal runoff artery. , 1976, The Journal of thoracic and cardiovascular surgery.

[32]  M. Papadaki,et al.  Effects of Fluid Shear Stress on Gene Regulation of Vascular Cells , 1997, Biotechnology progress.

[33]  V. Sottiurai,et al.  Distal anastomotic intimal hyperplasia: histopathologic character and biogenesis. , 1989, Annals of vascular surgery.

[34]  S Glagov,et al.  Measurements of velocity and wall shear stress inside a PTFE vascular graft model under steady flow conditions. , 1997, Journal of biomechanical engineering.

[35]  C Kleinstreuer,et al.  Flow input waveform effects on the temporal and spatial wall shear stress gradients in a femoral graft-artery connector. , 1996, Journal of biomechanical engineering.

[36]  A. Clowes,et al.  Secondary femoropopliteal reconstruction. , 1981, Annals of surgery.

[37]  R. Sanders,et al.  The significance of graft diameter. , 1980, Surgery.

[38]  D. Brewster,et al.  Factors affecting patency of femoropopliteal bypass grafts. , 1983, Surgery, gynecology & obstetrics.

[39]  R. Dilley,et al.  A review of the histologic changes in vein-to-artery grafts, with particular reference to intimal hyperplasia. , 1988, Archives of surgery.

[40]  B. Berk,et al.  Laminar shear stress: mechanisms by which endothelial cells transduce an atheroprotective force. , 1998, Arteriosclerosis, thrombosis, and vascular biology.

[41]  W. R. Johnson,et al.  Conformational stress and anastomotic hyperplasia. , 1984, Journal of vascular surgery.

[42]  C. Zarins,et al.  Compensatory enlargement of human atherosclerotic coronary arteries. , 1987, The New England journal of medicine.

[43]  K. Morinaga,et al.  Effect of wall shear stress on intimal thickening of arterially transplanted autogenous veins in dogs. , 1985, Journal of vascular surgery.