Simulation and experimental validation of the variable-refrigerant-volume (VRV) air-conditioning system in EnergyPlus

In order to evaluate the energy performance of the VRV air-conditioning system, a new simulation module is developed and validated experimentally in this study, on the basis of the building energy simulation program, EnergyPlus. The differences between average monitored and predicted data for the total cooling energy and power use are proved to be within 25.19% and 28.31%, respectively. Also, the relative error of power usage simulation follows that of cooling energy closely on an hourly basis. The COP and PLR simulation of the VRV system are also examined, with average error of 6.36% for COP and 18.40% for PLR. It is observed through the test that the energy performance of the VRV system at part-load condition is better than that in the rated condition.

[1]  Michael J. Witte,et al.  Analytical and comparative testing of EnergyPlus using IEA HVAC BESTEST E100-E200 test suite , 2004 .

[2]  Shuangquan Shao,et al.  Performance representation of variable-speed compressor for inverter air conditioners based on experimental data , 2004 .

[3]  Moncef Krarti,et al.  Parametric analysis of active and passive building thermal storage utilization , 2005 .

[4]  Ruzhu Wang,et al.  Energy simulation in the variable refrigerant flow air-conditioning system under cooling conditions , 2007 .

[5]  Daniel E. Fisher,et al.  Modular HVAC Simulation and the Future Integration of Alternative Cooling Systems in a New Building Energy Simulation Program , 2002 .

[6]  Frederick C. Winkelmann,et al.  Modeling Windows in EnergyPlus , 2001 .

[7]  Shih-Cheng Hu,et al.  Development and testing of a multi-type air conditioner without using AC inverters , 2004 .

[8]  Takahiko Miyazaki,et al.  Energy savings of office buildings by the use of semi-transparent solar cells for windows , 2005 .

[9]  Yong Chan Kim,et al.  Capacity modulation of an inverter-driven multi-air conditioner using electronic expansion valves , 2003 .

[10]  Mohammad S. Al-Homoud,et al.  Computer-aided building energy analysis techniques , 2001 .

[11]  S. C. Sekhar,et al.  Indoor air quality and energy issues of refrigerant modulating air-conditioning systems in the tropics , 2003 .

[12]  B. T. Griffith,et al.  Photovoltaic and Solar Thermal Modeling with the EnergyPlus Calculation Engine: Preprint , 2004 .

[13]  Richard Karl Strand,et al.  Modeling radiant heating and cooling systems: integration with a whole-building simulation program , 2005 .

[14]  Young Chul Kim,et al.  Performance analysis on a multi-type inverter air conditioner , 2001 .

[15]  Tianzhen Hong,et al.  Building simulation: an overview of developments and information sources , 2000 .