Super-Resolution Microscopy Using Standard Fluorescent Proteins in Intact Cells under Cryo-Conditions

We introduce a super-resolution technique for fluorescence cryo-microscopy based on photoswitching of standard genetically encoded fluorescent marker proteins in intact mammalian cells at low temperature (81 K). Given the limit imposed by the lack of cryo-immersion objectives, current applications of fluorescence cryo-microscopy to biological specimens achieve resolutions between 400–500 nm only. We demonstrate that the single molecule characteristics of reversible photobleaching of mEGFP and mVenus at liquid nitrogen temperature are suitable for the basic concept of single molecule localization microscopy. This enabled us to perform super-resolution imaging of vitrified biological samples and to visualize structures in unperturbed fast frozen cells for the first time with a structural resolution of ∼125 nm (average single molecule localization accuracy ∼40 nm), corresponding to a 3–5 fold resolution improvement.

[1]  Thorsten Staudt,et al.  Molecular orientation affects localization accuracy in superresolution far-field fluorescence microscopy. , 2011, Nano letters.

[2]  Andrew Leis,et al.  Visualizing cells at the nanoscale. , 2009, Trends in biochemical sciences.

[3]  Songye Chen,et al.  Correlated light and electron cryo-microscopy. , 2010, Methods in enzymology.

[4]  V. Adam,et al.  Low-temperature switching by photoinduced protonation in photochromic fluorescent proteins , 2010, Photochemical & photobiological sciences : Official journal of the European Photochemistry Association and the European Society for Photobiology.

[5]  M. Gustafsson,et al.  Super-resolution 3D microscopy of live whole cells using structured illumination , 2011, Nature Methods.

[6]  X. Zhuang,et al.  Fast three-dimensional super-resolution imaging of live cells , 2011, Nature Methods.

[7]  S. Hell,et al.  Fluorescence nanoscopy by ground-state depletion and single-molecule return , 2008, Nature Methods.

[8]  Matthew D Lew,et al.  Rotational mobility of single molecules affects localization accuracy in super-resolution fluorescence microscopy. , 2013, Nano letters.

[9]  I. Hurbain,et al.  The future is cold: cryo‐preparation methods for transmission electron microscopy of cells , 2011, Biology of the cell.

[10]  Michael A Thompson,et al.  Super-resolution imaging in live Caulobacter crescentus cells using photoswitchable EYFP , 2008, Nature Methods.

[11]  Alois Renn,et al.  Cryogenic colocalization microscopy for nanometer-distance measurements. , 2014, Chemphyschem : a European journal of chemical physics and physical chemistry.

[12]  J. Dubochet,et al.  Comparison of different methods for thin section EM analysis of Mycobacterium smegmatis , 2010, Journal of microscopy.

[13]  W. Moerner,et al.  Illuminating single molecules in condensed matter. , 1999, Science.

[14]  S. Rehbein,et al.  Cryo X-ray microscope with flat sample geometry for correlative fluorescence and nanoscale tomographic imaging. , 2012, Journal of structural biology.

[15]  Michael D. Mason,et al.  Ultra-high resolution imaging by fluorescence photoactivation localization microscopy. , 2006, Biophysical journal.

[16]  Stefan W. Hell,et al.  Supporting Online Material Materials and Methods Figs. S1 to S9 Tables S1 and S2 References Video-rate Far-field Optical Nanoscopy Dissects Synaptic Vesicle Movement , 2022 .

[17]  M. Hausmann,et al.  SPDM: light microscopy with single-molecule resolution at the nanoscale , 2008 .

[18]  M. Burghammer,et al.  Scanning X-Ray Nanodiffraction on Living Eukaryotic Cells in Microfluidic Environments , 2014 .

[19]  James A Galbraith,et al.  Super-resolution microscopy at a glance , 2011, Journal of Cell Science.

[20]  M. Brecht,et al.  Confocal sample-scanning microscope for single-molecule spectroscopy and microscopy with fast sample exchange at cryogenic temperatures. , 2012, The Review of scientific instruments.

[21]  Mark Bates,et al.  Evaluation of fluorophores for optimal performance in localization-based super-resolution imaging , 2011, Nature Methods.

[22]  J. McIntosh,et al.  Cryo‐fluorescence microscopy facilitates correlations between light and cryo‐electron microscopy and reduces the rate of photobleaching , 2007, Journal of microscopy.

[23]  S. Hell,et al.  Aberrations in confocal fluorescence microscopy induced by mismatches in refractive index , 1993 .

[24]  G. McDermott,et al.  High‐aperture cryogenic light microscopy , 2009, Journal of microscopy.

[25]  M. Gustafsson,et al.  Subdiffraction Multicolor Imaging of the Nuclear Periphery with 3D Structured Illumination Microscopy , 2008, Science.

[26]  K. Grünewald,et al.  High-precision correlative fluorescence and electron cryo microscopy using two independent alignment markers☆ , 2014, Ultramicroscopy.

[27]  Michael J Rust,et al.  Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM) , 2006, Nature Methods.

[28]  Felix J. B. Bäuerlein,et al.  Micromachining tools and correlative approaches for cellular cryo-electron tomography. , 2010, Journal of structural biology.

[29]  J. Lippincott-Schwartz,et al.  Imaging Intracellular Fluorescent Proteins at Nanometer Resolution , 2006, Science.

[30]  Florian Beck,et al.  Correlative microscopy: bridging the gap between fluorescence light microscopy and cryo-electron tomography. , 2007, Journal of structural biology.

[31]  Abraham J Koster,et al.  Tools for correlative cryo-fluorescence microscopy and cryo-electron tomography applied to whole mitochondria in human endothelial cells. , 2009, European journal of cell biology.

[32]  S. Hell Microscopy and its focal switch , 2008, Nature Methods.

[33]  S. Hell,et al.  Breaking the diffraction resolution limit by stimulated emission: stimulated-emission-depletion fluorescence microscopy. , 1994, Optics letters.

[34]  M. Gustafsson Surpassing the lateral resolution limit by a factor of two using structured illumination microscopy , 2000, Journal of microscopy.