Time resolved X-ray Dark-Field Tomography Revealing Water Transport in a Fresh Cement Sample

Grating-based X-ray dark-field tomography is a promising technique for biomedical and materials research. Even if the resolution of conventional X-ray tomography does not suffice to resolve relevant structures, the dark-field signal provides valuable information about the sub-pixel microstructural properties of the sample. Here, we report on the potential of X-ray dark-field imaging to be used for time-resolved three-dimensional studies. By repeating consecutive tomography scans on a fresh cement sample, we were able to study the hardening dynamics of the cement paste in three dimensions over time. The hardening of the cement was accompanied by a strong decrease in the dark-field signal pointing to microstructural changes within the cement paste. Furthermore our results hint at the transport of water from certain limestone grains, which were embedded in the sample, to the cement paste during the process of hardening. This is indicated by an increasing scattering signal which was observed for two of the six tested limestone grains. Electron microscopy images revealed a distinct porous structure only for those two grains which supports the following interpretation of our results. When the water filled pores of the limestone grains empty during the experiment the scattering signal of the grains increases.

[1]  Atsushi Momose,et al.  Effects of unresolvable edges in grating-based X-ray differential phase imaging. , 2015, Optics express.

[2]  G. Denbeaux,et al.  A soft X-ray microscope investigation into the effects of calcium chloride on tricalcium silicate hydration , 2005 .

[3]  Franz Pfeiffer,et al.  Dark-field X-ray imaging of unsaturated water transport in porous materials , 2014 .

[4]  K. Kurtis,et al.  Proposed mechanism of C-S-H growth tested by soft X-ray microscopy , 2000 .

[5]  Thomas Buslaps,et al.  3D-Quantification of the distribution of continuous fibres in unidirectionally reinforced composites , 2009 .

[6]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[7]  Franz Pfeiffer,et al.  X-ray tensor tomography , 2014 .

[8]  Franz Pfeiffer,et al.  Interlaced phase stepping in phase-contrast x-ray tomography , 2011 .

[9]  Christian Germain,et al.  Microstructure reconstruction of fibrous C/C composites from X-ray microtomography , 2007 .

[10]  Daniel Cusson,et al.  Internal curing of high-performance concrete with pre-soaked fine lightweight aggregate for prevention of autogenous shrinkage cracking , 2008 .

[11]  Johann Kastner,et al.  Laminate fibre structure characterisation of carbon fibre-reinforced polymers by X-ray scatter dark field imaging with a grating interferometer , 2013 .

[12]  Yining Zhu,et al.  Micro-CT artifacts reduction based on detector random shifting and fast data inpainting. , 2013, Medical physics.

[13]  V Ntziachristos,et al.  Three‐dimensional imaging of whole mouse models: comparing nondestructive X‐ray phase‐contrast micro‐CT with cryotome‐based planar epi‐illumination imaging , 2013, Journal of microscopy.

[14]  K. Kovler,et al.  Prevention of autogenous shrinkage in high-strength concrete by internal curing using wet lightweight aggregates , 2001 .

[15]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[16]  H. Reinhardt,et al.  Continuous monitoring of setting and hardening of mortar and concrete , 2004 .

[17]  F. Pfeiffer,et al.  Trimodal low-dose X-ray tomography , 2012, Proceedings of the National Academy of Sciences.

[18]  Franz Pfeiffer,et al.  Quantitative x-ray dark-field computed tomography , 2010, Physics in medicine and biology.

[19]  A. Momose,et al.  On the origin of visibility contrast in x-ray Talbot interferometry. , 2010, Optics express.

[20]  F. Pfeiffer,et al.  Observing the setting and hardening of cementitious materials by X-ray dark-field radiography , 2015 .

[21]  O. Bunk,et al.  Hard-X-ray dark-field imaging using a grating interferometer. , 2008, Nature materials.

[22]  Franz Pfeiffer,et al.  Lens-term- and edge-effect in X-ray grating interferometry. , 2015, Biomedical optics express.

[23]  Kejun Kang,et al.  Quantitative grating-based x-ray dark-field computed tomography , 2009 .

[24]  Franz Pfeiffer,et al.  Short-range order in mesoscale systems probed by X-ray grating interferometry , 2015 .

[25]  Franz Pfeiffer,et al.  Multi-contrast 3D X-ray imaging of porous and composite materials , 2015 .

[26]  M. Strobl General solution for quantitative dark-field contrast imaging with grating interferometers , 2014, Scientific reports.

[27]  Atsushi Momose,et al.  Effect of beam hardening on a visibility-contrast image obtained by X-ray grating interferometry. , 2015, Optics express.

[28]  Timm Weitkamp,et al.  X-ray vector radiography for bone micro-architecture diagnostics , 2012, Physics in medicine and biology.

[29]  Franz Pfeiffer,et al.  Detection of sub-pixel fractures in X-ray dark-field tomography , 2015 .