Clinical Performance of Implantable Cardioverter Defibrillator Lead Monitoring Diagnostics.

[1]  Ziad F Issa,et al.  Feasibility and Safety of Percutaneous Lead Revision for Subacute and Delayed Cardiac Device Lead Perforation. , 2020, JACC. Clinical electrophysiology.

[2]  M. Kroll,et al.  Impedance in the Diagnosis of Lead Malfunction. , 2020, Circulation. Arrhythmia and electrophysiology.

[3]  M. Kroll,et al.  Why Low-Voltage Shock Impedance Measurements Fail to Reliably Detect Insulation Breaches in Transvenous Defibrillation Leads. , 2019, Heart rhythm.

[4]  L. Stanberry,et al.  Internal insulation breaches in an implantable cardioverter-defibrillator lead with redundant conductors. , 2019, Heart rhythm.

[5]  B. Wilkoff,et al.  Antibacterial Envelope to Prevent Cardiac Implantable Device Infection , 2019, The New England journal of medicine.

[6]  C. Swerdlow,et al.  Monitoring for and Diagnosis of Lead Dysfunction. , 2018, Cardiac electrophysiology clinics.

[7]  M. Haïssaguerre,et al.  Towards eradication of inappropriate therapies for ICD lead failure by combining comprehensive remote monitoring and lead noise alerts , 2018, Journal of cardiovascular electrophysiology.

[8]  E. Gang,et al.  Early Diagnosis of Defibrillation Lead Dislodgement. , 2018, JACC. Clinical electrophysiology.

[9]  K. Ellenbogen,et al.  Multicenter investigation of an implantable cardioverter-defibrillator algorithm to detect oversensing. , 2017, Heart rhythm.

[10]  Arnaud Lazarus,et al.  Optimizing Implantable Cardioverter-Defibrillator Remote Monitoring: A Practical Guide. , 2017, JACC. Clinical electrophysiology.

[11]  C. Swerdlow,et al.  Sensing and detection in Medtronic implantable cardioverter defibrillators , 2016, Herzschrittmachertherapie + Elektrophysiologie.

[12]  A. Krahn,et al.  Lead Integrity Alert Is Useful for Assessment of Performance of Biotronik Linox Leads , 2015, Journal of cardiovascular electrophysiology.

[13]  Kenneth A Ellenbogen,et al.  Troubleshooting implanted cardioverter defibrillator sensing problems I. , 2014, Circulation. Arrhythmia and electrophysiology.

[14]  K. Ellenbogen,et al.  Performance of Lead Integrity Alert to Assist in the Clinical Diagnosis of Implantable Cardioverter Defibrillator Lead Failures: Analysis of Different Implantable Cardioverter Defibrillator Leads , 2013, Circulation. Arrhythmia and electrophysiology.

[15]  K. Ellenbogen,et al.  Diagnosis of high-voltage conductor fractures in Sprint Fidelis leads. , 2013, Heart rhythm.

[16]  K. Ellenbogen,et al.  Preventing overdiagnosis of implantable cardioverter-defibrillator lead fractures using device diagnostics. , 2011, Journal of the American College of Cardiology.

[17]  K. Ellenbogen,et al.  Downloadable Software Algorithm Reduces Inappropriate Shocks Caused by Implantable Cardioverter-Defibrillator Lead Fractures: A Prospective Study , 2010, Circulation.

[18]  K. Ellenbogen,et al.  Causes of ventricular oversensing in implantable cardioverter-defibrillators: implications for diagnosis of lead fracture. , 2010, Heart rhythm.

[19]  K. Ellenbogen,et al.  Downloadable Algorithm to Reduce Inappropriate Shocks Caused by Fractures of Implantable Cardioverter-Defibrillator Leads , 2008, Circulation.

[20]  K. Ellenbogen,et al.  Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure. , 2006, Heart rhythm.

[21]  M. Schoenfeld,et al.  Troubleshooting Implantable Cardioverter Defibrillator System Malfunctions: The Role of Impedance Measurements , 1994, Pacing and clinical electrophysiology : PACE.