3D tumor localization through real-time volumetric x-ray imaging for lung cancer radiotherapy.

PURPOSE To evaluate an algorithm for real-time 3D tumor localization from a single x-ray projection image for lung cancer radiotherapy. METHODS Recently, we have developed an algorithm for reconstructing volumetric images and extracting 3D tumor motion information from a single x-ray projection [Li et al., Med. Phys. 37, 2822-2826 (2010)]. We have demonstrated its feasibility using a digital respiratory phantom with regular breathing patterns. In this work, we present a detailed description and a comprehensive evaluation of the improved algorithm. The algorithm was improved by incorporating respiratory motion prediction. The accuracy and efficiency of using this algorithm for 3D tumor localization were then evaluated on (1) a digital respiratory phantom, (2) a physical respiratory phantom, and (3) five lung cancer patients. These evaluation cases include both regular and irregular breathing patterns that are different from the training dataset. RESULTS For the digital respiratory phantom with regular and irregular breathing, the average 3D tumor localization error is less than 1 mm which does not seem to be affected by amplitude change, period change, or baseline shift. On an NVIDIA Tesla C1060 graphic processing unit (GPU) card, the average computation time for 3D tumor localization from each projection ranges between 0.19 and 0.26 s, for both regular and irregular breathing, which is about a 10% improvement over previously reported results. For the physical respiratory phantom, an average tumor localization error below 1 mm was achieved with an average computation time of 0.13 and 0.16 s on the same graphic processing unit (GPU) card, for regular and irregular breathing, respectively. For the five lung cancer patients, the average tumor localization error is below 2 mm in both the axial and tangential directions. The average computation time on the same GPU card ranges between 0.26 and 0.34 s. CONCLUSIONS Through a comprehensive evaluation of our algorithm, we have established its accuracy in 3D tumor localization to be on the order of 1 mm on average and 2 mm at 95 percentile for both digital and physical phantoms, and within 2 mm on average and 4 mm at 95 percentile for lung cancer patients. The results also indicate that the accuracy is not affected by the breathing pattern, be it regular or irregular. High computational efficiency can be achieved on GPU, requiring 0.1-0.3 s for each x-ray projection.

[1]  V Latrabe,et al.  CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle. , 2000, Clinical radiology.

[2]  Gregory C Sharp,et al.  Prediction of respiratory tumour motion for real-time image-guided radiotherapy. , 2004, Physics in medicine and biology.

[3]  Jean-Philippe Pignol,et al.  Correlation of lung tumor motion with external surrogate indicators of respiration. , 2004, International journal of radiation oncology, biology, physics.

[4]  Steve B. Jiang,et al.  Multiple template-based fluoroscopic tracking of lung tumor mass without implanted fiducial markers , 2007, Physics in medicine and biology.

[5]  J. S. Laughlin,et al.  Radiation treatment planning , 1977, Cancer.

[6]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[7]  Jeffrey Williamson,et al.  A method to map errors in the deformable registration of 4DCT imagesa). , 2010, Medical physics.

[8]  Koichi Yamazaki,et al.  Real‐time tumor‐tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy , 2002, Cancer.

[9]  D Ruan,et al.  Real-time prediction of respiratory motion based on local regression methods , 2007, Physics in medicine and biology.

[10]  Paul Keall,et al.  Online prediction of respiratory motion: multidimensional processing with low-dimensional feature learning , 2010, Physics in medicine and biology.

[11]  Joakim Jalden,et al.  Adaptive filtering to predict lung tumor motion during free breathing , 2002 .

[12]  Qinghui Zhang,et al.  A patient-specific respiratory model of anatomical motion for radiation treatment planning. , 2007, Medical physics.

[13]  Steve B. Jiang,et al.  Markerless lung tumor tracking and trajectory reconstruction using rotational cone-beam projections: a feasibility study , 2010, Physics in medicine and biology.

[14]  Steve B Jiang,et al.  Implementation and evaluation of various demons deformable image registration algorithms on a GPU. , 2010, Physics in medicine and biology.

[15]  Steve B. Jiang,et al.  Real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy. , 2010, Medical physics.

[16]  Steve B. Jiang,et al.  Lung tumor tracking in fluoroscopic video based on optical flow. , 2008, Medical physics.

[17]  Jeffrey A. Fessler,et al.  Estimating 3-D Respiratory Motion From Orbiting Views by Tomographic Image Registration , 2007, IEEE Transactions on Medical Imaging.

[18]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[19]  J. Dempsey,et al.  Novel breathing motion model for radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[20]  Y. Tsunashima,et al.  Correlation between the respiratory waveform measured using a respiratory sensor and 3D tumor motion in gated radiotherapy. , 2004, International journal of radiation oncology, biology, physics.

[21]  Steve B. Jiang,et al.  Fluoroscopic tumor tracking for image-guided lung cancer radiotherapy , 2009, Physics in medicine and biology.

[22]  Weiguo Lu,et al.  A simple fixed-point approach to invert a deformation field. , 2007, Medical physics.