Normal Molecular Repair Mechanisms in Regenerative Peripheral Nerve Interfaces Allow Recording of Early Spike Activity Despite Immature Myelination

Clinical use of neurally controlled prosthetics has advanced in recent years, but limitations still remain, including lacking fine motor control and sensory feedback. Indwelling multi-electrode arrays, cuff electrodes, and regenerative sieve electrodes have been reported to serve as peripheral neural interfaces, though long-term stability of the nerve-electrode interface has remained a formidable challenge. We recently developed a regenerative multi-electrode interface (REMI) that is able to record neural activity as early as seven days post-implantation. While this activity might represent normal neural depolarization during axonal regrowth, it can also be the result of altered nerve regeneration around the REMI. This study evaluated high-throughput expression levels of 84 genes involved in nerve injury and repair, and the histological changes that occur in parallel to this early neural activity. Animals exhibiting spike activity increased from 29% to 57% from 7 to 14 days following REMI implantation with a corresponding increase in firing rate of 113%. Two weeks after implantation, numbers of neurofilament-positive axons in the control and REMI implanted nerves were comparable, and in both cases the number of myelinated axons was low. During this time, expression levels of genes related to nerve injury and repair were similar in regenerated nerves, both in the presence or absence of the electrode array. Together, these results indicate that the early neural activity is intrinsic to the regenerating axons, and not induced by the REMI neurointerface.

[1]  Dominique M. Durand,et al.  Chronic measurement of the stimulation selectivity of the flat interface nerve electrode , 2004, IEEE Transactions on Biomedical Engineering.

[2]  Jeffrey A. Loeb,et al.  Neuregulin-1 Type III Determines the Ensheathment Fate of Axons , 2005, Neuron.

[3]  T. Kuiken,et al.  Improved Myoelectric Prosthesis Control Using Targeted Reinnervation Surgery: A Case Series , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[4]  Silvestro Micera,et al.  A Computational Model for the Stimulation of Rat Sciatic Nerve Using a Transverse Intrafascicular Multichannel Electrode , 2011, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[5]  N A Fitzsimmons,et al.  Primate Reaching Cued by Multichannel Spatiotemporal Cortical Microstimulation , 2007, The Journal of Neuroscience.

[6]  Eduardo Fernández,et al.  Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve , 2004, IEEE Transactions on Biomedical Engineering.

[7]  Daryl R Kipke,et al.  Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants , 2007, Journal of neural engineering.

[8]  Kathryn Ziegler-Graham,et al.  Estimating the prevalence of limb loss in the United States: 2005 to 2050. , 2008, Archives of physical medicine and rehabilitation.

[9]  Justin C. Williams,et al.  Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex , 2004, IEEE Transactions on Biomedical Engineering.

[10]  D. Zochodne,et al.  Early events of peripheral nerve regeneration. , 2005, Neuron glia biology.

[11]  J. Caldwell,et al.  Sodium channel Na(v)1.6 is localized at nodes of ranvier, dendrites, and synapses. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[12]  Luca Citi,et al.  Decoding Information From Neural Signals Recorded Using Intraneural Electrodes: Toward the Development of a Neurocontrolled Hand Prosthesis , 2010, Proceedings of the IEEE.

[13]  J. Salzer,et al.  Glial Growth Factor/Neuregulin Inhibits Schwann Cell Myelination and Induces Demyelination , 2001, The Journal of cell biology.

[14]  M. Swiontkowski,et al.  Redirection of cutaneous sensation from the hand to the chest skin of human amputees with targeted reinnervation , 2009 .

[15]  Richard A Normann,et al.  Technology Insight: future neuroprosthetic therapies for disorders of the nervous system , 2007, Nature Clinical Practice Neurology.

[16]  S. Hall REGENERATION IN CELLULAR AND ACELLULAR AUTOGRAFTS IN THE PERIPHERAL NERVOUS SYSTEM , 1986, Neuropathology and applied neurobiology.

[17]  Mario I. Romero,et al.  Early Interfaced Neural Activity from Chronic Amputated Nerves , 2009, Front. Neuroeng..

[18]  DM Durand,et al.  Models of the peripheral nerves for detection and control of neural activity , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[19]  D. Zochodne,et al.  Axon and Schwann Cell Partnership During Nerve Regrowth , 2005, Journal of neuropathology and experimental neurology.

[20]  K. Horch,et al.  Residual function in peripheral nerve stumps of amputees: implications for neural control of artificial limbs. , 2004, The Journal of hand surgery.

[21]  X Liu,et al.  Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[22]  P. F. Adams,et al.  Current estimates from the National Health Interview Survey, 1996. , 1999, Vital and health statistics. Series 10, Data from the National Health Survey.

[23]  J R Schwarz,et al.  Heterogeneous distribution of fast and slow potassium channels in myelinated rat nerve fibres. , 1989, The Journal of physiology.

[24]  Jon A. Mukand,et al.  Neuronal ensemble control of prosthetic devices by a human with tetraplegia , 2006, Nature.

[25]  P. F. Adams,et al.  Current estimates from the National Health Interview Survey, 1994. , 1995, Vital and health statistics. Series 10, Data from the National Health Survey.

[26]  David C. Martin,et al.  Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays , 2005, Experimental Neurology.

[27]  G. Lemke,et al.  Identification and purification of glial growth factor , 1984, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[28]  Patrick A Tresco,et al.  The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull. , 2007, Journal of biomedical materials research. Part A.

[29]  Robert D. Lipschutz,et al.  Improved Myoelectric Prosthesis Control Accomplished Using Multiple Nerve Transfers , 2006, Plastic and reconstructive surgery.

[30]  Gennadij Raivich,et al.  Molecular mechanisms in successful peripheral regeneration , 2005, The FEBS journal.

[31]  E. Mackenzie,et al.  Limb Amputation and Limb Deficiency: Epidemiology and Recent Trends in the United States , 2002, Southern medical journal.

[32]  R V Bellamkonda,et al.  Bioimpedance modeling to monitor astrocytic response to chronically implanted electrodes , 2009, Journal of neural engineering.

[33]  Clayton J. Underwood,et al.  Characterization of microglial attachment and cytokine release on biomaterials of differing surface chemistry. , 2008, Biomaterials.

[34]  Y. Yarden,et al.  Neu differentiation factor is a neuron-glia signal and regulates survival, proliferation, and maturation of rat schwann cell precursors , 1995, Neuron.

[35]  Jeff Biernaskie,et al.  Skin-Derived Precursors Generate Myelinating Schwann Cells for the Injured and Dysmyelinated Nervous System , 2006, The Journal of Neuroscience.

[36]  Klaus-Armin Nave,et al.  Axonal regulation of myelination by neuregulin 1 , 2006, Current Opinion in Neurobiology.

[37]  Mark Ellisman,et al.  Node of Ranvier formation along fibres regenerating through silicone tube implants: A freeze-fracture and thin-section electron microscopic study , 1987, Journal of neurocytology.