Effects of control system failures on transients and accidents at a 3-loop Westinghouse pressurized water reactor. Volume 2. Appendices

Safety Implications of Control Systems (A-47) was approved as an Unresolved Safety Issue (USI) by the Nuclear Regulatory Commission (NRC) in December of 1980. USI A-47 is concerned with the potential for transients or accidents being made more severe than previously analyzed as a result of control system failures. This report describes the work performed on the effects of control system failures on transients and accidents at a Westinghouse 3-loop pressurized water reactor. In this volume, the appendices contain detailed information consisting of the FMEA (failure mode and analysis) results, an in-depth description of the computer model, the deterministic computer analyses, and responses to comments made by Carolina Power and Light Company and Westinghouse Electric Corporation.