Transient performance and stability analysis of a hybrid grid-connected wind/PV system

This paper presents both stability analyzed results and transient performance of a small hybrid wind/PV power generation system connected to a low-voltage distribution system. The studied system includes two identical wind cage-rotor induction generators, a PV module, a battery storage system, and a rectifier-inverter module. Both simulated and measured transient results of the studied system subject to disturbance conditions are examined and compared. The required minimum self-excited capacitance of the studied wind induction generators is also determined. Small-signal stability of the studied system under different rotor speeds is evaluated using eigenvalue approach. It can be concluded from the analyzed results that the proposed simulated model is adequate to simulate the performance of the studied practical hybrid grid-connected wind/PV system.

[1]  Li Wang,et al.  Analysis of isolated self-excited induction generator feeding a rectifier load , 2002 .

[2]  Li Wang,et al.  Steady-State Performance of a Self-Excited Induction Generator Feeding an Induction Motor , 2002 .

[3]  Li Wang,et al.  Random fluctuations on dynamic stability of a grid-connected photovoltaic array , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[4]  Jarl-Thure Eriksson,et al.  A permanent-magnet generator for wind power applications , 1996 .

[5]  Li Wang,et al.  A novel analysis on the performance of an isolated self-excited induction generator , 1997 .

[6]  Giri Venkataramanan,et al.  Generation unit sizing and cost analysis for stand-alone wind, photovoltaic, and hybrid wind/PV systems , 1998 .

[7]  David Infield,et al.  Predicting islanding operation of grid connected PV inverters , 2000 .

[8]  Li Wang,et al.  Analysis of voltage control for a self-excited induction generator using a current-controlled voltage source inverter (CC-VSI) , 2001 .

[9]  Trevor Pryor,et al.  Novel wind/diesel/battery hybrid energy system , 1993 .

[10]  Ziyad M. Salameh,et al.  Methodology for optimally sizing the combination of a battery bank and PV array in a wind/PV hybrid system , 1996 .

[11]  Roberto Cardenas,et al.  Power limitation in variable speed wind turbines with fixed pitch angle , 1996 .

[12]  O. P. Malik,et al.  Simulation of internal faults in synchronous generators , 1997 .

[13]  F. Valenciaga,et al.  Power control of a solar/wind generation system without wind measurement: a passivity/sliding mode approach , 2003 .

[14]  Paul C. Krause,et al.  Analysis of electric machinery , 1987 .

[15]  Jay Jayadev Harnessing the wind , 1995 .

[16]  F. Valenciaga,et al.  Passivity/sliding mode control of a stand-alone hybrid generation system , 2000 .

[17]  Wu Wei,et al.  Electrical equipment for a combined wind/PV isolated generating system , 1996 .

[18]  Li Wang,et al.  Dynamic stability analyses of a photovoltaic array connected to a large utility grid , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[19]  Stavros A. Papathanassiou,et al.  Dynamic behavior of variable speed wind turbines under stochastic wind , 1999 .