Low GWP R134a replacements for small refrigeration (plug-in) applications

This paper presents a performance evaluation of two low global warming potential (GWP) refrigerants, R1234yf and R1234ze(E), as replacements for R134a. A theoretical comparison is first presented based on the thermodynamic properties of the refrigerants. Tests are carried out in a representative vending machine system (cassette) at two representative outdoor ambient temperatures of 32.2°C (efficiency test), and 40.5°C (capacity test) and return air temperatures of 2°C, 20°C and 38°C. Under drop-in conditions, R1234yf shows performance similar to R134a. For R1234ze(E), a refrigerant with lower volumetric cooling capacity, testing was done using a larger compressor to obtain capacity recovery. A simulation model is used to analyze the system design changes, which can lead to further improvement in the performance of low GWP refrigerants. Overall, the results indicate that with minor design changes, such as use of a suction-line/liquid-line heat exchanger and modifications to the refrigerant circuitry, these refrigerants can match the performance of R134a.

[1]  Chi-Chuan Wang,et al.  Investigation of the two-phase convective boiling of HFO-1234yf in a 3.9 mm diameter tube , 2013 .

[2]  Honghyun Cho,et al.  Performance characteristics of an automobile air conditioning system with internal heat exchanger using refrigerant R1234yf , 2013 .

[3]  Chaobin Dang,et al.  Boiling heat transfer of HFO-1234yf flowing in a smooth small-diameter horizontal tube , 2010 .

[4]  Mark W. Spatz,et al.  An evaluation of options for replacing HCFC-22 in medium temperature refrigeration systems , 2004 .

[5]  Dongsoo Jung,et al.  Nucleate boiling heat transfer coefficients of R1234yf on plain and low fin surfaces , 2010 .

[6]  J. Navarro-Esbrí,et al.  Experimental analysis of R1234yf as a drop-in replacement for R134a in a vapor compression system , 2013 .

[7]  S. Bortolin,et al.  Condensation heat transfer and two-phase frictional pressure drop in a single minichannel with R1234ze(E) and other refrigerants , 2015 .

[8]  Dongsoo Jung,et al.  A brief performance comparison of R1234yf and R134a in a bench tester for automobile applications , 2012 .

[9]  Condensation in two phase and desuperheating zone for R1234ze(E), R134a and R32 in horizontal smooth tubes. , 2015 .

[10]  Mark W. Spatz,et al.  Analysis of low-GWP alternatives for small refrigeration (plugin) applications. , 2010 .

[11]  Chi-Chuan Wang An overview for the heat transfer performance of HFO-1234yf , 2013 .

[12]  John R. Thome,et al.  Flow pattern map, heat transfer and pressure drops during evaporation of R-1234ze(E) and R134a in a horizontal, circular smooth tube: Experiments and assessment of predictive methods , 2013 .