Development of a Personal Sampler for Evaluating Exposure to Ultrafine Particles

Evaluation of the exposure of humans to ultrafine, airborne particles is an important aspect of health in the workplace, especially in cases where nano-particles are present. However, portable sampling devices for efficiently collecting ultrafine particles in a worker's breathing zone are not readily available. The present study describes the design and development of a portable sampler for collecting particulates in the breathing zone, as a possible tool for this purpose. The design is based on the use of an ”Inertial Filter” to separate various-sized nano-order particles. Inertial filters consisting of SUS fiber felt (fiber diameter 5.6-13.5 μm) placed in circular nozzles (3-6 mm diameter with 4.5 mm length) were used. To achieve the smallest dp50 under the allowable pressure drop of a portable pump, the influence of fiber loading on separation performance and pressure drop were investigated. The influence of particle loading was also examined in relation to pressure drop and separation performance. The smallest dp50 under the allowable pressure drop (5.7 kPa at 6 L/min) for the battery pump employed was ~140 and 200 nm respectively for SUS fibers of 5.6 and 9.8 μm diameter (particle volume fraction ~0.013). The change in separation performance due to particle loading was confirmed to be acceptable for use under the present conditions. Under these conditions, a sufficient amount of particles can be collected for chemical analyses, e.g., particle-bound PAHs after 6-8 hours of sampling. Hence, the developed sampler has the potential for use in evaluating exposure to ultrafine particles in the breathing zone in the workplace.

[1]  K. Iinoya,et al.  Experimental Studies on the Pressure Drop Characteristics of Fiber Mats , 1959 .

[2]  P. Mcmurry,et al.  Measurement of Inherent Material Density of Nanoparticle Agglomerates , 2004 .

[3]  W E Bolch,et al.  Influences of parameter uncertainties within the ICRP 66 respiratory tract model: particle deposition. , 2001, Health physics.

[4]  J. J. Collins,et al.  Design and evaluation of a new low-pressure impactor. 2 , 1979 .

[5]  K. T. Whitby,et al.  Aerosol classification by electric mobility: apparatus, theory, and applications , 1975 .

[6]  F. Iskandar,et al.  Measurement of the Effective Density of Both Spherical Aggregated and Ordered Porous Aerosol Particles Using Mobility- and Mass-Analyzers , 2009 .

[7]  Peter H. McMurry,et al.  A Design Tool for Aerodynamic Lens Systems , 2006 .

[8]  P. Mcmurry,et al.  Structural Properties of Diesel Exhaust Particles Measured by Transmission Electron Microscopy (TEM): Relationships to Particle Mass and Mobility , 2004 .

[9]  P. Tekasakul,et al.  Workplace Environment and Personal Exposure of PM and PAHs to Workers in Natural Rubber Sheet Factories Contaminated by Wood Burning Smoke , 2010 .

[10]  I. Nisbet,et al.  Toxic equivalency factors (TEFs) for polycyclic aromatic hydrocarbons (PAHs). , 1992, Regulatory toxicology and pharmacology : RTP.

[11]  F. J. Alguacil,et al.  Thin coating on ultrafine aerosol particles , 2006 .

[12]  K. Spurny Analytical chemistry of aerosols , 1999 .

[13]  K. Okuyama,et al.  Brownian coagulation of two-component ultrafine aerosols , 1986 .

[14]  Richard C. Flagan,et al.  Design and evaluation of new low-pressure impactor. I , 1978 .

[15]  Yoshio Otani,et al.  Inertial Classification of Nanoparticles with Fibrous Filters , 2007 .

[16]  Risto Hillamo,et al.  Modification of the University of Washington Mark 5 in-stack impactor , 1989 .

[17]  Kenneth L. Rubow,et al.  Effect of Flow-induced Relative Humidity Changes on Size Cuts for Sulfuric Acid Droplets in the Microorifice Uniform Deposit Impactor (MOUDI) , 1991 .

[18]  K. Okuyama,et al.  Development of a mixing type condensation nucleus counter , 1982 .