Segmentation of prostate boundaries from ultrasound images using statistical shape model

Presents a statistical shape model for the automatic prostate segmentation in transrectal ultrasound images. A Gabor filter bank is first used to characterize the prostate boundaries in ultrasound images in both multiple scales and multiple orientations. The Gabor features are further reconstructed to be invariant to the rotation of the ultrasound probe and incorporated in the prostate model as image attributes for guiding the deformable segmentation. A hierarchical deformation strategy is then employed, in which the model adaptively focuses on the similarity of different Gabor features at different deformation stages using a multiresolution technique, i.e., coarse features first and fine features later. A number of successful experiments validate the algorithm.

[1]  Dinggang Shen,et al.  HAMMER: hierarchical attribute matching mechanism for elastic registration , 2002, IEEE Transactions on Medical Imaging.

[2]  K. Raghunath Rao,et al.  Optimal Edge Detection using Expansion Matching and Restoration , 1994, IEEE Trans. Pattern Anal. Mach. Intell..

[3]  Curtis Mettlin,et al.  American cancer society national prostate cancer detection project. Goals and current status , 1995 .

[4]  Timothy F. Cootes,et al.  Active Shape Models-Their Training and Application , 1995, Comput. Vis. Image Underst..

[5]  Dinggang Shen,et al.  An Adaptive-Focus Deformable Model Using Statistical and Geometric Information , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[6]  Mariano Alcañiz Raya,et al.  Outlining of the prostate using snakes with shape restrictions based on the wavelet transform , 1999, Pattern Recognit..

[7]  Milan Sonka,et al.  Segmentation and interpretation of MR brain images. An improved active shape model , 1998, IEEE Transactions on Medical Imaging.

[8]  Yongmin Kim,et al.  Edge-guided boundary delineation in prostate ultrasound images , 2000, IEEE Transactions on Medical Imaging.

[9]  Timothy F. Cootes,et al.  Use of active shape models for locating structures in medical images , 1994, Image Vis. Comput..

[10]  U. G. Dailey Cancer,Facts and Figures about. , 2022, Journal of the National Medical Association.

[11]  Timothy F. Cootes,et al.  Active Appearance Models , 2001, IEEE Trans. Pattern Anal. Mach. Intell..

[12]  Timothy F. Cootes,et al.  The Use of Active Shape Models for Locating Structures in Medical Images , 1993, IPMI.

[13]  Dinggang Shen,et al.  Very High-Resolution Morphometry Using Mass-Preserving Deformations and HAMMER Elastic Registration , 2003, NeuroImage.

[14]  Donal B. Downey,et al.  Three-dimensional ultrasound imaging of the prostate , 1998, Medical Imaging.

[15]  C R Hill,et al.  Review article: high intensity focused ultrasound--potential for cancer treatment. , 1995, The British journal of radiology.

[16]  B. S. Manjunath,et al.  Texture Features for Browsing and Retrieval of Image Data , 1996, IEEE Trans. Pattern Anal. Mach. Intell..

[17]  F F Yin,et al.  A three-dimensional deformable model for segmentation of human prostate from ultrasound images. , 2001, Medical physics.

[18]  Dinggang Shen,et al.  An adaptive-focus statistical shape model for segmentation and shape modeling of 3-D brain structures , 2001, IEEE Transactions on Medical Imaging.

[19]  Donal B. Downey,et al.  Three-dimensional ultrasound imaging , 1995, Medical Imaging.

[20]  M. Terris,et al.  Determination of prostate volume by transrectal ultrasound. , 1991, The Journal of urology.

[21]  M. Terris,et al.  Random systematic versus directed ultrasound guided transrectal core biopsies of the prostate. , 1989, The Journal of urology.