Characterization of atherosclerosis plaques by measuring both backscattering and attenuation coefficients in optical coherence tomography.

Intravascular optical coherence tomography (OCT) has been proven a powerful diagnostic tool for cardiovascular diseases. However, the optical mechanism for the qualitative observations are still absent. We address the fundamental issues that underlie the tissue characterization of OCT images obtained from coronary arteries. For this, we investigate both the attenuation and the backscattering properties of different plaque components of postmortem human cadaver coronary arteries. The artery samples are examined both from lumen surface using a catheter and from transversely cut surface using an OCT microscope, where OCT images could be matched to histology exactly. Light backscattering coefficient microb and attenuation coefficients microt are determined for three basic plaque types based on a single-scattering physical model: calcification (microb=4.9+/-1.5 mm(-1), microt=5.7+/-1.4 mm(-1)), fibers (microb=18.4+/-6.4 mm(-1), microt=6.4+/-1.2 mm(-1)), and lipid pool (microb=28.1+/-8.9 mm(-1), microt=13.7+/-4.5 mm(-1)). Our results not only explain the origins of many qualitative OCT features, but also show that combination of backscattering and attenuation coefficient measurements can be used for contrast enhancing and better tissue characterization.

[1]  Brett E. Bouma,et al.  In Vivo Characterization of Coronary Atherosclerotic Plaque by Use of Optical Coherence Tomography , 2005, Circulation.

[2]  T. G. van Leeuwen,et al.  Quantitative optical coherence tomography of arterial wall components , 2005, Lasers in Medical Science.

[3]  David Levitz,et al.  Determination of optical scattering properties of highly-scattering media in optical coherence tomography images. , 2004, Optics express.

[4]  R. Virmani,et al.  Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions. , 2000, Arteriosclerosis, thrombosis, and vascular biology.

[5]  Ton G van Leeuwen,et al.  Temperature-dependent optical properties of individual vascular wall components measured by optical coherence tomography. , 2006, Journal of biomedical optics.

[6]  M J Davies,et al.  Stability and instability: two faces of coronary atherosclerosis. The Paul Dudley White Lecture 1995. , 1996, Circulation.

[7]  John A. Evans,et al.  Comprehensive volumetric optical microscopy in vivo , 2006, Nature Medicine.

[8]  P. Fitzgerald,et al.  Images in cardiovascular medicine. Intracoronary imaging with optical coherence tomography: a new high-resolution technology providing striking visualization in the coronary artery. , 2002, Circulation.

[9]  J. Willerson,et al.  Prologue: Detection of Vulnerable Plaque , 2006 .

[10]  J. Fujimoto,et al.  Optical coherence tomography for optical biopsy. Properties and demonstration of vascular pathology. , 1996, Circulation.

[11]  Dirk J. Faber,et al.  Localized measurement of optical attenuation coefficients of atherosclerotic plaque constituents by quantitative optical coherence tomography , 2005, IEEE Transactions on Medical Imaging.

[12]  Y. Neishi,et al.  Measurement of the thickness of the fibrous cap by optical coherence tomography. , 2006, American heart journal.

[13]  Bin Liu,et al.  Assessment of coronary plaque collagen with polarization sensitive optical coherence tomography (PS-OCT). , 2006, International journal of cardiology.

[14]  J. Schmitt,et al.  Measurement of optical properties of biological tissues by low-coherence reflectometry. , 1993, Applied optics.

[15]  Bin Liu,et al.  Theoretical and practical considerations on detection performance of time domain, Fourier domain, and swept source optical coherence tomography. , 2007, Journal of biomedical optics.

[16]  Brett E Bouma,et al.  Measurement of collagen and smooth muscle cell content in atherosclerotic plaques using polarization-sensitive optical coherence tomography. , 2007, Journal of the American College of Cardiology.

[17]  Massoud Motamedi,et al.  Precision of measurement of tissue optical properties with optical coherence tomography. , 2003, Applied optics.

[18]  V. Fuster,et al.  Coronary plaque disruption. , 1995, Circulation.

[19]  E. Halpern,et al.  Characterization of Human Atherosclerosis by Optical Coherence Tomography , 2002, Circulation.

[20]  K. Seung,et al.  Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. , 2002, Journal of the American College of Cardiology.

[21]  B. Bouma,et al.  Optical coherence tomography for imaging the vulnerable plaque. , 2006, Journal of biomedical optics.

[22]  L V Wang,et al.  Anisotropy in the absorption and scattering spectra of chicken breast tissue. , 1998, Applied optics.

[23]  J. Fujimoto,et al.  Buffered Fourier domain mode locking: Unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s. , 2006, Optics letters.

[24]  Takashi Akasaka,et al.  Assessment of culprit lesion morphology in acute myocardial infarction: ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy. , 2007, Journal of the American College of Cardiology.