A fluid dynamic analysis using flow visualization of the Baylor/NASA implantable axial flow blood pump for design improvement.

The Baylor/NASA Axial Blood Flow Pump has been developed for use as an implantable left ventricular assist device (LVAD). The pump is intended as an assist device for either pulmonary or systemic circulatory support for more than 3-months' duration. To date the pump provides acceptable results in terms of thrombus formation and hemolysis (IH of 0.018 g/100 L). A fluid dynamics analysis using flow visualization was performed to investigate the flow fields and to determine areas within the pump that could be improved. These studies focused upon the inflow area in front of the pump. A prototype axial flow pump assembly was constructed to facilitate the flow visualization studies. Particle image tracking velocimetry techniques were used to measure Amberlite particles suspended in a blood analog fluid composed of 63% water and 37% glycerin. This method used a pulsed (612 Hz) laser light to determine flow velocity profiles, shear stress, Reynolds numbers, and stagnant areas within the axial pump. These studies showed that the flow straightener (a vaned assembly in the pump inflow) reduced Reynolds numbers from 4,640 to 2,540 (at 8.5 L/min) and that the flow straightener exacerbates a discontinuity found between it and the impeller. Within the inflow area, a maximum of 80 N/m2 shear stress was measured, which is well below published blood damage thresholds. Design variations were investigated resulting in a smoother flow transition between flow straightener and impeller. These variations must be investigated further to establish a correlation with hemolysis and thrombus formation.

[1]  J M Fuqua,et al.  Treatment of cardiac allograft failure by use of an intraaortic axial flow pump. , 1990, The Journal of heart transplantation.

[2]  J F Antaki,et al.  Fluorescent image tracking velocimetry of the Nimbus AxiPump. , 1993, ASAIO journal.

[3]  G P Noon,et al.  Bio-medicus ventricular assistance. , 1991, The Annals of thoracic surgery.

[4]  Y Nosé,et al.  Development of the Baylor/NASA axial flow ventricular assist device: in vitro performance and systematic hemolysis test results. , 1994, Artificial organs.

[5]  W S Pierce,et al.  Combined Registry for the Clinical Use of Mechanical Ventricular Assist Pumps and the Total Artificial Heart in conjunction with heart transplantation: sixth official report--1994. , 1995, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[6]  Y Nosé,et al.  The need for standardizing the index of hemolysis. , 1994, Artificial organs.

[7]  J D Hellums,et al.  Red blood cell damage by shear stress. , 1972, Biophysical journal.