Clutter reduction in echocardiography with short-lag spatial coherence (SLSC) imaging

Clutter, a problematic noise artifact in echocardiography, appears as a diffuse haze that obscures endocardial borders and inhibits accurate diagnoses. Several approaches are available to reduce clutter in cardiac images, yet difficult-to-image patients still exist. We have recently developed a novel imaging method, termed short-lag spatial coherence (SLSC) imaging, that has demonstrated potential to reduce clutter in simulated and experimental data. With this technique, images are created from the same individual channel signals used to form B-mode images, but instead of applying a conventional delay-and-sum beamformer, the data are cross-correlated to measure and display differences in spatial coherence. This technique was applied to in vivo cardiac images. Individual channel signals were acquired to form matched B-mode and SLSC images of the left ventricle in fourteen human volunteers. The contrast and contrast-to-noise ratio (CNR) of the ventricle and the signal-to-noise ratio (SNR) of the endocardium were measured in the same locations in matched B-mode and SLSC images. In SLSC images created with a short-lag value equivalent to 16% of the transmit aperture, contrast and CNR was improved by 9±7 dB and 0.4±0.2, respectively, in the SLSC images. The average SNR of the endocardium was 1.7±0.4 in the SLSC images and 1.8±0.4 in the B-mode images. The presented approach demonstrates a new method for reducing clutter in cardiac images.

[1]  Dongwoon Hyun,et al.  Lesion Detectability in Diagnostic Ultrasound with Short-Lag Spatial Coherence Imaging , 2011, Ultrasonic imaging.

[2]  S. Sawada,et al.  Enhanced endocardial visualization with noncontrast harmonic imaging during stress echocardiography. , 1999, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[3]  J G Miller,et al.  Contrast Echocardiography: Current and Future Applications , 2000 .

[4]  Pieter A Doevendans,et al.  Cardiovascular Ultrasound BioMed Central Review , 2006 .

[5]  M. Averkiou,et al.  A new imaging technique based on the nonlinear properties of tissues , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[6]  A. C. Baker,et al.  Nonlinear propagation applied to the improvement of resolution in diagnostic medical ultrasound. , 1997, The Journal of the Acoustical Society of America.

[7]  F. Duck Nonlinear acoustics in diagnostic ultrasound. , 2002, Ultrasound in medicine & biology.

[8]  J.G. Miller,et al.  Spatial coherence of the nonlinearly generated second harmonic portion of backscatter for a clinical imaging system , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  Jeffrey C. Bamber,et al.  Spatial Coherence and Beamformer Gain , 2002 .

[10]  L Pourcelot,et al.  Clinical use of ultrasound tissue harmonic imaging. , 1999, Ultrasound in medicine & biology.

[11]  J. Thomsen,et al.  Cardiac metastasis from transitional cell carcinoma: A subtle echocardiographic entity , 1980, Journal of clinical ultrasound : JCU.

[12]  G. E. Trahey,et al.  Short-lag spatial coherence of backscattered echoes: imaging characteristics , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  Solange Akselrod,et al.  Stationary clutter rejection in echocardiography. , 2006, Ultrasound in medicine & biology.

[14]  Donato Mele,et al.  Improved detection of left ventricular thrombi and spontaneous echocontrast by tissue harmonic imaging in patients with myocardial infarction. , 2006, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[15]  P. Hanrath Transoesophageal Echo-Doppler in cardiology , 2001 .

[16]  John A. Hossack,et al.  The Singular Value Filter: A General Filter Design Strategy for PCA-Based Signal Separation in Medical Ultrasound Imaging , 2011, IEEE Transactions on Medical Imaging.

[17]  P Stritoni,et al.  Impact of harmonic imaging on transthoracic echocardiographic identification of infective endocarditis and its complications , 2005, Heart.

[18]  C Caiati,et al.  Contrast-enhanced transthoracic second harmonic echo Doppler with adenosine: a noninvasive, rapid and effective method for coronary flow reserve assessment. , 1999, Journal of the American College of Cardiology.

[19]  Gregg E. Trahey,et al.  Sources and characterization of clutter in cardiac B-mode images , 2009, 2009 IEEE International Ultrasonics Symposium.