In vivo three-dimensional kinematics of normal knees during different high-flexion activities

Aims In Asia and the Middle‐East, people often flex their knees deeply in order to perform activities of daily living. The purpose of this study was to investigate the 3D kinematics of normal knees during high‐flexion activities. Our hypothesis was that the femorotibial rotation, varus‐valgus angle, translations, and kinematic pathway of normal knees during high‐flexion activities, varied according to activity. Materials and Methods We investigated the in vivo kinematics of eight normal knees in four male volunteers (mean age 41.8 years; 37 to 53) using 2D and 3D registration technique, and modelled the knees with a computer aided design program. Each subject squatted, kneeled, and sat crosslegged. We evaluated the femoral rotation and varus‐valgus angle relative to the tibia and anteroposterior translation of the medial and lateral side, using the transepicodylar axis as our femoral reference relative to the perpendicular projection on to the tibial plateau. This method evaluates the femur medially from what has elsewhere been described as the extension facet centre, and differs from the method classically applied. Results During squatting and kneeling, the knees displayed femoral external rotation. When sitting cross‐legged, femurs displayed internal rotation from 10° to 100°. From 100°, femoral external rotation was observed. No significant difference in varus‐valgus angle was seen between squatting and kneeling, whereas a varus position was observed from 140° when sitting cross‐legged. The measure kinematic pathway using our methodology found during squatting a medial pivoting pattern from 0° to 40° and bicondylar rollback from 40° to 150°. During kneeling, a medial pivot pattern was evident. When sitting cross‐legged, a lateral pivot pattern was seen from 0° to 100°, and a medial pivot pattern beyond 100°. Conclusion The kinematics of normal knees during high flexion are variable according to activity. Nevertheless, our study was limited to a small number of male patients using a different technique to report the kinematics than previous publications. Accordingly, caution should be observed in generalizing our findings.

[1]  H. Yoshikawa,et al.  In vivo three-dimensional motion analysis of osteoarthritic knees , 2013, Modern rheumatology.

[2]  G. Scott,et al.  The Medial Rotation total knee replacement: a clinical and radiological review at a mean follow-up of six years. , 2009, The Journal of bone and joint surgery. British volume.

[3]  D. Dennis,et al.  In Vivo Fluoroscopic Analysis of the Normal Human Knee , 2003, Clinical orthopaedics and related research.

[4]  L. Sandvik,et al.  A simple method for accurate rotational positioning of the femoral component in total knee arthroplasty , 2017, Acta orthopaedica.

[5]  Y Yamano,et al.  Tibiofemoral movement 3: full flexion in the living knee studied by MRI. , 2000, The Journal of bone and joint surgery. British volume.

[6]  Harry E Rubash,et al.  In vivo tibiofemoral contact analysis using 3D MRI-based knee models. , 2004, Journal of biomechanics.

[7]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[8]  S. Banks,et al.  Fluoroscopic motion study confirming the stability of a medial pivot design total knee arthroplasty. , 2015, The Knee.

[9]  V Pinskerova,et al.  Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee. , 2000, The Journal of bone and joint surgery. British volume.

[10]  Daisuke Takahashi,et al.  Intraoperative medial pivot affects deep knee flexion angle and patient-reported outcomes after total knee arthroplasty. , 2014, The Journal of arthroplasty.

[11]  J. Tamura,et al.  In Vivo Three-Dimensional Knee Kinematics Using a Biplanar Image-Matching Technique , 2001, Clinical orthopaedics and related research.

[12]  H. Yoshikawa,et al.  Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy. , 2005, European journal of radiology.

[13]  B. Beynnon,et al.  The Transepicondylar Axis Approximates the Optimal Flexion Axis of the Knee , 1998, Clinical orthopaedics and related research.

[14]  Chung-Ming Chen,et al.  A volumetric model-based 2D to 3D registration method for measuring kinematics of natural knees with single-plane fluoroscopy. , 2010, Medical physics.

[15]  R. Laskin Flexion space configuration in total knee arthroplasty. , 1995, The Journal of arthroplasty.

[16]  Scott L Delp,et al.  The variability of femoral rotational alignment in total knee arthroplasty. , 2005, The Journal of bone and joint surgery. American volume.

[17]  A. Williams,et al.  Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using 'interventional' MRI. , 2005, Journal of biomechanics.

[18]  U P Wyss,et al.  Hip, knee, and ankle kinematics of high range of motion activities of daily living , 2006, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[19]  Y. Iwamoto,et al.  In vivo kinematics of healthy male knees during squat and golf swing using image-matching techniques. , 2016, The Knee.

[20]  Masao Akagi,et al.  The functional flexion-extension axis of the knee corresponds to the surgical epicondylar axis: in vivo analysis using a biplanar image-matching technique. , 2005, The Journal of arthroplasty.

[21]  Naoto Endo,et al.  Three-dimensional in vivo motion analysis of normal knees using single-plane fluoroscopy , 2011, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[22]  Scott Tashman,et al.  In vivo measurement of 3-D skeletal kinematics from sequences of biplane radiographs: Application to knee kinematics , 2001, IEEE Transactions on Medical Imaging.

[23]  D. Bae,et al.  Clinical outcome of total knee arthroplasty with medial pivot prosthesis a comparative study between the cruciate retaining and sacrificing. , 2011, The Journal of arthroplasty.

[24]  Satoshi Hamai,et al.  Dynamic activity dependence of in vivo normal knee kinematics , 2008, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[25]  山崎 隆治 Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy , 2004 .

[26]  Satoshi Hamai,et al.  In Vivo Healthy Knee Kinematics during Dynamic Full Flexion , 2012, BioMed research international.

[27]  E. Valstar,et al.  Transepicondylar axis accuracy in computer assisted knee surgery: A comparison of the CT-based measured axis versus the CAS-determined axis , 2008, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[28]  Sakae Tanaka,et al.  An additional reference axis improves femoral rotation alignment in image-free computer navigation assisted total knee arthroplasty. , 2013, The Journal of arthroplasty.

[29]  Benjamin J Fregly,et al.  Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy. , 2005, Journal of biomechanical engineering.

[30]  V. Pinskerova,et al.  BJR can a total knee arthroplasty be both rotationally unconstrained and anteroposteriorly stabilised ? a pulsed fluoRoscopic investigation , 2016 .

[31]  U. Wyss,et al.  Knee kinematics of high-flexion activities of daily living performed by male Muslims in the Middle East. , 2011, The Journal of arthroplasty.

[32]  V Pinskerova,et al.  Tibiofemoral movement 2: the loaded and unloaded living knee studied by MRI. , 2000, The Journal of bone and joint surgery. British volume.

[33]  D. Shakespeare,et al.  Can the epicondylar axis be defined accurately in total knee arthroplasty? , 2005, The Knee.

[34]  Mohamed Mahfouz,et al.  In Vivo Three-Dimensional Determination of Kinematics for Subjects with a Normal Knee or a Unicompartmental or Total Knee Replacement , 2001, The Journal of bone and joint surgery. American volume.

[35]  Ming-Shium Hsieh,et al.  Primitive results after medial-pivot knee arthroplasties: a minimum 5-year follow-up study. , 2010, The Journal of arthroplasty.

[36]  M. Hull,et al.  Does A Kinematically Aligned Total Knee Arthroplasty Restore Function Without Failure Regardless of Alignment Category? , 2013, Clinical orthopaedics and related research.

[37]  Ashutosh Kumar Singh,et al.  The Axes of Rotation of the Knee , 1993, Clinical orthopaedics and related research.

[38]  J. G. Bonnin,et al.  ARTHROPLASTY , 1956, Der Orthopade.