Fuzzy Inference System Approach for Locating Series, Shunt, and Simultaneous Series-Shunt Faults in Double Circuit Transmission Lines

Many schemes are reported for shunt fault location estimation, but fault location estimation of series or open conductor faults has not been dealt with so far. The existing numerical relays only detect the open conductor (series) fault and give the indication of the faulty phase(s), but they are unable to locate the series fault. The repair crew needs to patrol the complete line to find the location of series fault. In this paper fuzzy based fault detection/classification and location schemes in time domain are proposed for both series faults, shunt faults, and simultaneous series and shunt faults. The fault simulation studies and fault location algorithm have been developed using Matlab/Simulink. Synchronized phasors of voltage and current signals of both the ends of the line have been used as input to the proposed fuzzy based fault location scheme. Percentage of error in location of series fault is within 1% and shunt fault is 5% for all the tested fault cases. Validation of percentage of error in location estimation is done using Chi square test with both 1% and 5% level of significance.

[1]  Aleena Swetapadma,et al.  All shunt fault location including cross-country and evolving faults in transmission lines without fault type classification , 2015 .

[2]  M.M. Saha,et al.  Fault location on parallel transmission lines with series compensation , 2004, 2004 IEEE/PES Transmision and Distribution Conference and Exposition: Latin America (IEEE Cat. No. 04EX956).

[3]  M. Jayabharata Reddy,et al.  Performance Evaluation of an Adaptive-Network-Based Fuzzy Inference System Approach for Location of Faults on Transmission Lines Using Monte Carlo Simulation , 2008, IEEE Transactions on Fuzzy Systems.

[4]  Sami Ekici,et al.  A transmission line fault locator based on Elman recurrent networks , 2009, Appl. Soft Comput..

[5]  George N. Korres,et al.  Accurate fault location algorithm for double-circuit series compensated lines using a limited number of two-end synchronized measurements , 2012 .

[6]  S. R. Samantaray,et al.  A systematic fuzzy rule based approach for fault classification in transmission lines , 2013, Appl. Soft Comput..

[7]  Eugeniusz Rosolowski,et al.  A new accurate fault locating algorithm for series compensated lines , 1999 .

[8]  R. Feuillet,et al.  Accurate fault location algorithm for series compensated transmission lines , 2000 .

[9]  V. Cook Distance protection performance during simultaneous faults , 1977 .

[10]  F. M. Abouelenin A complete algorithm to fault calculation due to simultaneous faults. "Combination of short circuits and open lines" , 2002, 11th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.02CH37379).

[11]  P.M.S. Burt,et al.  Broken conductors protection system using carrier communication , 2000 .

[12]  P. La Seta,et al.  A new unsynchronized two-terminals fault location method on series compensated lines , 2005, 2005 IEEE Russia Power Tech.

[13]  J. Izykowski,et al.  Fault Location on Double-Circuit Series-Compensated Lines Using Two-End Unsynchronized Measurements , 2011, IEEE Transactions on Power Delivery.

[14]  J. Izykowski,et al.  Fault Locator Using Two-End Unsynchronized Measurements for UHV Series Compensated Parallel Lines , 2008, 2008 International Conference on High Voltage Engineering and Application.

[15]  G. J. Cokkinides,et al.  Open conductor detector system , 1991 .

[16]  M. Gilany,et al.  ANN based technique for enhancement of distance relay performance against open-conductor in HV transmission lines , 2010, 2010 The 2nd International Conference on Computer and Automation Engineering (ICCAE).

[17]  M. Jayabharata Reddy,et al.  Smart Fault Location for Smart Grid Operation Using RTUs and Computational Intelligence Techniques , 2014, IEEE Systems Journal.

[18]  Eugeniusz Rosolowski,et al.  New concept for fault location in series-compensated parallel lines , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[19]  Mladen Kezunovic,et al.  Automated transmission line fault analysis using synchronized sampling at two ends , 1995 .

[20]  A. Abur,et al.  Traveling-Wave-Based Fault-Location Technique for Transmission Grids Via Wide-Area Synchronized Voltage Measurements , 2012, IEEE Transactions on Power Systems.

[21]  Eugeniusz Rosolowski,et al.  DIFFERENTIAL EQUATION BASED FAULT LOCATION ALGORITHM FOR SERIES-COMPENSATED TRANSMISSION LINES , 2005 .

[22]  M. Jayabharata Reddy,et al.  A wavelet-fuzzy combined approach for classification and location of transmission line faults , 2007 .

[23]  Sami Ekici,et al.  Support Vector Machines for classification and locating faults on transmission lines , 2012, Appl. Soft Comput..

[24]  Guobing Song,et al.  An accurate fault location algorithm for parallel transmission lines using one-terminal data , 2009 .

[25]  Gang Wang,et al.  A New Method for Open Conductors Fault Calculation of Four-parallel Transmission Lines , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[26]  B. R. Bhalja,et al.  A New Digital Distance Relaying Scheme for Series-Compensated Double-Circuit Line During Open Conductor and Ground Fault , 2012, IEEE Transactions on Power Delivery.

[27]  Aleena Swetapadma,et al.  A single ended directional fault section identifier and fault locator for double circuit transmission lines using combined wavelet and ANN approach , 2015 .

[28]  I. Zamora,et al.  Best ANN structures for fault location in single-and double-circuit transmission lines , 2005, IEEE Transactions on Power Delivery.