Acoustic characterization of high intensity focused ultrasound fields: a combined measurement and modeling approach.

Acoustic characterization of high intensity focused ultrasound (HIFU) fields is important both for the accurate prediction of ultrasound induced bioeffects in tissues and for the development of regulatory standards for clinical HIFU devices. In this paper, a method to determine HIFU field parameters at and around the focus is proposed. Nonlinear pressure waveforms were measured and modeled in water and in a tissue-mimicking gel phantom for a 2 MHz transducer with an aperture and focal length of 4.4 cm. Measurements were performed with a fiber optic probe hydrophone at intensity levels up to 24,000 W/cm(2). The inputs to a Khokhlov-Zabolotskaya-Kuznetsov-type numerical model were determined based on experimental low amplitude beam plots. Strongly asymmetric waveforms with peak positive pressures up to 80 MPa and peak negative pressures up to 15 MPa were obtained both numerically and experimentally. Numerical simulations and experimental measurements agreed well; however, when steep shocks were present in the waveform at focal intensity levels higher than 6000 W/cm(2), lower values of the peak positive pressure were observed in the measured waveforms. This underrepresentation was attributed mainly to the limited hydrophone bandwidth of 100 MHz. It is shown that a combination of measurements and modeling is necessary to enable accurate characterization of HIFU fields.

[1]  Vera A. Khokhlova,et al.  Numerical modeling of finite-amplitude sound beams: Shock formation in the near field of a cw plane piston source , 2001 .

[2]  K. Parker,et al.  New approaches to nonlinear diffractive field propagation. , 1991, The Journal of the Acoustical Society of America.

[4]  D. R. Bacon,et al.  Absorption of finite amplitude focused ultrasound. , 1991, The Journal of the Acoustical Society of America.

[5]  G. Harris,et al.  Progress in medical ultrasound exposimetry , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Hughes,et al.  On the applicability of Kramers-Kronig relations for ultrasonic attenuation obeying a frequency power law , 2000, The Journal of the Acoustical Society of America.

[7]  D. Cathignol,et al.  INVESTIGATION OF A HIGH INTENSITY SOUND BEAM FROM A PLANE TRANSDUCER. EXPERIMENTAL AND THEORETICAL RESULTS , 1995 .

[8]  M. Hamilton,et al.  Nonlinear distortion of short pulses radiated by plane and focused circular pistons. , 1997, The Journal of the Acoustical Society of America.

[9]  A. D. Bond,et al.  The influence of waveform distortion on hydrophone spatial‐averaging corrections—Theory and measurement , 1992 .

[10]  Shahram Vaezy,et al.  Therapeutic Ultrasound, Part II * . High Intensity Focused Ultrasound: A Method of Hemostasis , 2001, Echocardiography.

[11]  E. G. Radulescu,et al.  Hydrophone spatial averaging corrections from 1 to 40 MHz , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  R A Smith,et al.  Are hydrophones of diameter 0.5 mm small enough to characterise diagnostic ultrasound equipment? , 1989, Physics in medicine and biology.

[13]  Wen-zhi Chen,et al.  Extracorporeal focused ultrasound surgery for treatment of human solid carcinomas: early Chinese clinical experience. , 2004, Ultrasound in medicine & biology.

[14]  Charles R. Thomas,et al.  Dynamics and control of cavitation during high-intensity focused ultrasound application , 2005 .

[15]  F. Gleeson,et al.  High-intensity focused ultrasound for the treatment of liver tumours. , 2004, Ultrasonics.

[16]  Oleg A. Sapozhnikov,et al.  COMPARISON OF ACOUSTIC FIELDS RADIATED FROM PIEZOCERAMIC AND PIEZOCOMPOSITE FOCUSED RADIATORS , 1999 .

[17]  D. R. Bacon,et al.  Finite amplitude distortion of the pulsed fields used in diagnostic ultrasound. , 1984, Ultrasound in medicine & biology.

[18]  J. Staudenraus,et al.  Fibre-optic probe hydrophone for ultrasonic and shock-wave measurements in water , 1993 .

[19]  E. Carstensen,et al.  Finite amplitude distortion and its relationship to linear derating formulae for diagnostic ultrasound systems. , 1996, Ultrasound in medicine & biology.

[20]  J. Brian Fowlkes,et al.  A cost effective degassing system for use in ultrasonic measurements: The multiple pinhole degassing system , 1996 .

[21]  E. Jaynes,et al.  Kramers–Kronig relationship between ultrasonic attenuation and phase velocity , 1981 .

[22]  R Souchon,et al.  Modeling of pulsed finite-amplitude focused sound beams in time domain. , 1998, The Journal of the Acoustical Society of America.

[23]  Vera A. Khokhlova,et al.  Effect of acoustic nonlinearity on heating of biological tissue by high-intensity focused ultrasound , 2001 .

[24]  Oleg A. Sapozhnikov,et al.  Lamb waves in piezoelectric focused radiator as a reason for discrepancy between O’Neil’s formula and experiment , 1997 .

[25]  K Hynynen,et al.  Demonstration of enhanced temperature elevation due to nonlinear propagation of focussed ultrasound in dog's thigh in vivo. , 1987, Ultrasound in medicine & biology.

[26]  Gregory T. Clement,et al.  Clinical applications of focused ultrasound—The brain , 2007, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[27]  P. W. Bridgman The Pressure‐Volume‐Temperature Relations of the Liquid, and the Phase Diagram of Heavy Water , 1935 .

[28]  P. Meaney,et al.  The intensity dependence of lesion position shift during focused ultrasound surgery. , 2000, Ultrasound in medicine & biology.

[29]  L. Crum,et al.  Nonlinear pulsed ultrasound beams radiated by rectangular focused diagnostic transducers , 2006 .

[30]  R. Cleveland,et al.  Modeling of an electrohydraulic lithotripter with the KZK equation. , 1999, The Journal of the Acoustical Society of America.

[31]  F V Gleeson,et al.  The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population , 2005, British Journal of Cancer.

[32]  B. Gompf,et al.  Impluse response of a fiber optic probe hydrophone determined with shock waves in water , 1999 .

[33]  J. Debus,et al.  A new noninvasive approach in breast cancer therapy using magnetic resonance imaging-guided focused ultrasound surgery. , 2001, Cancer research.

[34]  Vesna Zderic,et al.  Gel phantom for use in high-intensity focused ultrasound dosimetry. , 2005, Ultrasound in medicine & biology.

[35]  L. Zhai,et al.  Measurement of high intensity focused ultrasound fields by a fiber optic probe hydrophone. , 2006, The Journal of the Acoustical Society of America.

[36]  Laura Curiel,et al.  Control of prostate cancer by transrectal HIFU in 227 patients. , 2007, European urology.

[37]  A. V. Morozov,et al.  Reconstruction of the normal velocity distribution on the surface of an ultrasonic transducer from the acoustic pressure measured on a reference surface , 2003 .

[38]  J. E. Parsons,et al.  Cost-effective assembly of a basic fiber-optic hydrophone for measurement of high-amplitude therapeutic ultrasound fields. , 2006, The Journal of the Acoustical Society of America.

[39]  H. O'neil Theory of Focusing Radiators , 1949 .

[40]  J. Ross Macdonald,et al.  Some Simple Isothermal Equations of State , 1966 .

[41]  Subha Maruvada,et al.  Acoustic power calibration of high-intensity focused ultrasound transducers using a radiation force technique. , 2007, The Journal of the Acoustical Society of America.

[42]  Thomas Dreyer,et al.  Full-wave modeling of therapeutic ultrasound: nonlinear ultrasound propagation in ideal fluids. , 2002, The Journal of the Acoustical Society of America.

[43]  Lawrence A Crum,et al.  Effects of nonlinear propagation, cavitation, and boiling in lesion formation by high intensity focused ultrasound in a gel phantom. , 2006, The Journal of the Acoustical Society of America.

[44]  Jeffrey C. Bamber,et al.  Physical Principles of Medical Ultrasonics: Hill/Physical Principles of Medical Ultrasonics, Second Edition , 2005 .

[45]  F A Duck Estimating in situ exposure in the presence of acoustic nonlinearity. , 1999, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[46]  R. Cleveland,et al.  Time domain simulation of nonlinear acoustic beams generated by rectangular pistons with application to harmonic imaging. , 2005, The Journal of the Acoustical Society of America.