A New Technique Implemented in Synchronous Reference Frame for DVR Control Under Severe Sag and Swell Conditions

Nowadays, power quality under the excessive implementation of power electronics devices is quite challenging issue. The compensation of non-sinusoidal; reactive and harmonic; components is the main role for power quality devices which highly depend on the robustness of the control system. Some common control systems are implemented using Synchronous Stationary Frame (DQ) theory. This paper proposes a new version of DQ control technique to control dynamic voltage restorer under severe transient voltage conditions. The power system network with the new DQ control technique is studied and analyzed under different scenarios to compensate for severe balanced and unbalanced voltage sags and swells. This new scheme is based on extraction of positive sequence components to implement the control algorithm. A mathematical model of the dynamic voltage restorer (DVR), hysteresis voltage control, converter controller model, new DQ scheme with complete system equations are carried out and verified using Simulink / MATLAB. The proposed system is validated experimentally using DSpace 1104 based laboratory system. The obtained results of the proposed compensation algorithm are compared with the results obtained from the traditional DQ method. Simulation and experimental results are correlated and show effectiveness of the proposed DQ control scheme.

[1]  J. L. Dantas,et al.  Fast and accurate voltage sag detection algorithm , 2022, International Journal of Electrical Power & Energy Systems.

[2]  A. S. Larik,et al.  Dynamic Voltage Restorer—A comprehensive review , 2021 .

[3]  Md. Ashib Rahman,et al.  A Novel Dual Slope Delta Modulation Technique for a Current Source Inverter Based Dynamic Voltage Restorer for Mitigation of Voltage Sags , 2021, IEEE Transactions on Industry Applications.

[4]  P. Sujatha,et al.  Control strategies for power quality enrichment in Distribution network using UPQC , 2021, Materials Today: Proceedings.

[5]  Renjini E. Nambiar,et al.  Comparative Study Between Different Controllers Of DVR For Power Quality Improvement , 2021, 2021 International Conference on Design Innovations for 3Cs Compute Communicate Control (ICDI3C).

[6]  S. Prathiba,et al.  Reparation of voltage disturbance using PR controller-based DVR in Modern power systems , 2021 .

[7]  Mim Naz Rahman,et al.  Voltage Sag Compensation in Distribution System Using Dynamic Voltage Restorer , 2020, 2020 2nd International Conference on Advanced Information and Communication Technology (ICAICT).

[8]  I. Sudiharto,et al.  A Single Phase Dynamic Voltage Restorer (DVR) With Direct AC-AC Converter Using dq Transform to Mitigate Voltage Sag , 2020, 2020 International Seminar on Application for Technology of Information and Communication (iSemantic).

[9]  Naser Abdel-Rahim,et al.  Enhanced DVR Control System Based on the Harris Hawks Optimization Algorithm , 2020, IEEE Access.

[10]  Sanjeevikumar Padmanaban,et al.  Dynamic Voltage Restorer (DVR): A Comprehensive Review of Topologies, Power Converters, Control Methods, and Modified Configurations , 2020 .

[11]  M. F. Azeem,et al.  Multiple Voltage Disturbance Compensation in Distribution Systems using DVR , 2020, Engineering, Technology & Applied Science Research.

[12]  Mughees Riaz,et al.  A new reliable Single-Stage Single-Phase Ac-Ac Converter based Dynamic Voltage Restorer for Voltage Sag/Swell compensation , 2020, 2020 3rd International Conference on Computing, Mathematics and Engineering Technologies (iCoMET).

[13]  Sushma Gupta,et al.  Topologies and Control Strategies Implicated in Dynamic Voltage Restorer (DVR) for Power Quality Improvement , 2020 .

[14]  El-Nobi A. Ibrahim,et al.  Dynamic Voltage Restorer for Enhancing Distribution Systems Power Quality , 2019, 2019 7th International Japan-Africa Conference on Electronics, Communications, and Computations, (JAC-ECC).

[15]  He Kaiming,et al.  Improved Instantaneous Derivation dq Detection Voltage Drop Method , 2019, 2019 IEEE 4th Advanced Information Technology, Electronic and Automation Control Conference (IAEAC).

[16]  M. Mariammal,et al.  Power Quality Improvement Using Dynamic Voltage Restorer , 2019, Bonfring International Journal of Power Systems and Integrated Circuits.

[17]  Pierluigi Siano,et al.  A Survey on Power System Blackout and Cascading Events: Research Motivations and Challenges , 2019, Energies.

[18]  Saud N. Abdulazeez,et al.  Design of Adaptive controller for Regulating the Voltage by a Dynamic Voltage Restorer DVR , 2019, 2019 2nd International Conference on Electrical, Communication, Computer, Power and Control Engineering (ICECCPCE).

[19]  A Karthikeyan,et al.  A Comparative Study of PI and PDF Controllers for DVR Under Distorted Grid Conditions , 2018, 2018 20th National Power Systems Conference (NPSC).

[20]  Arwindra Rizqiawan,et al.  DVR Control Based on Stationary Reference Frame for Unbalanced Voltage Sag Compensation , 2018, 2018 Conference on Power Engineering and Renewable Energy (ICPERE).

[21]  N. Rajasekar,et al.  A comprehensive review on protection challenges and fault diagnosis in PV systems , 2018, Renewable and Sustainable Energy Reviews.

[22]  V K Remya,et al.  Single-Phase DVR with Semi-Z-Source Inverter for Power Distribution Network , 2018 .

[23]  M. Nagesh,et al.  Comparative Analysis of Performance of D-STATCOM and DVR for Voltage sag, Voltage swell and Fault compensation , 2018 .

[24]  Frede Blaabjerg,et al.  A comprehensive review of dynamic voltage restorers , 2017 .

[25]  A Rini Ann Jerin,et al.  Improved fault ride through capability of DFIG based wind turbines using synchronous reference frame control based dynamic voltage restorer. , 2017, ISA transactions.

[26]  Lili Xie,et al.  New Decentralized Control Scheme for a Dynamic Voltage Restorer Based on the Elliptical Trajectory Compensation , 2017, IEEE Transactions on Industrial Electronics.

[27]  Euzeli C. dos Santos,et al.  Cascaded open-end winding transformer based DVR , 2016, 2016 IEEE Energy Conversion Congress and Exposition (ECCE).

[28]  S. Suraya SRF CONTROLLED DVR FOR COMPENSATION OF BALANCED AND UNBALANCED VOLTAGE DISTURBANCES , 2016 .

[29]  Daru Anna Thomas,et al.  Hysteresis controller based fault current interruption using DVR , 2014, 2014 Annual International Conference on Emerging Research Areas: Magnetics, Machines and Drives (AICERA/iCMMD).

[30]  Mahesh K. Mishra,et al.  A Control Scheme for Storageless DVR Based on Characterization of Voltage Sags , 2014, IEEE Transactions on Power Delivery.

[31]  Juraj Altus,et al.  Designing and modelling of a DVR in Matlab , 2014, Proceedings of the 2014 15th International Scientific Conference on Electric Power Engineering (EPE).

[32]  Mustafa Engin,et al.  Sizing and Simulation of PV-Wind Hybrid Power System , 2013 .

[33]  Manoj Gupta,et al.  DYNAMIC VOLTAGE RESTORER FOR COMPENSATION OF VOLTAGE SAG AND SWELL: A LITERATURE REVIEW , 2012 .

[34]  Amit K. Jain,et al.  Active Damping of Output $LC$ Filter Resonance for Vector-Controlled VSI-Fed AC Motor Drives , 2012, IEEE Transactions on Industrial Electronics.

[35]  Mekri Fatiha,et al.  New hysteresis control band of an unified power quality conditioner , 2011 .

[36]  J. Jeong,et al.  Novel Sag Detection Method for Line-Interactive Dynamic Voltage Restorer , 2010, IEEE Transactions on Power Delivery.

[37]  Xie Shaojun,et al.  A new detection method of voltage sag based on period phase concept , 2009, 2009 4th IEEE Conference on Industrial Electronics and Applications.

[38]  V. Cardenas,et al.  Selecting between linear and nonlinear control in a dynamic voltage restorer , 2008, 2008 IEEE Power Electronics Specialists Conference.

[39]  Amrita Rai,et al.  Modeling & Simulation of Dynamic Voltage Restorer (DVR) for Enhancing Voltage Sag , 2008 .

[40]  S. M. Deckmann,et al.  About voltage sags and swells analysis , 2002, 10th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.02EX630).

[41]  Mike Barnes,et al.  Dynamic voltage restorer with battery energy storage for voltage dip mitigation , 2000 .

[42]  Jaeho Choi,et al.  Output LC filter design of voltage source inverter considering the performance of controller , 2000, PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409).

[43]  Júlio S. Martins,et al.  Active filters with control based on the p-q theory , 2000 .

[44]  S.S. Choi,et al.  Control of energy optimized dynamic voltage restorer , 1999, IECON'99. Conference Proceedings. 25th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.99CH37029).