Synchronous fluorescence and excitation emission characteristics of transformer oil ageing.

This paper describes the evaluation of synchronous fluorescence spectroscopy (SFS) and excitation emission matrix fluorescence (EEMF) spectroscopy as means of monitoring transformer oil degradation. When accelerated thermal ageing method is used, the onset of degradation of transformer oil on 17th day and transformer oil with polypropylene and cellulosic paper on 23rd and 27th days is sensitively reflected in the SFS and EEMF fluorescence spectral characteristics.

[1]  S. Vijayakumari,et al.  Effect of antioxidants and metal deactivator on the oxidation of transformer oil , 1992 .

[2]  J. Unsworth,et al.  Degradation of electrical insulating paper monitored with high performance liquid chromatography , 1990 .

[3]  M. Ali,et al.  Spectroscopic studies of the ageing of cellulosic paper , 2001 .

[4]  Tapan Kumar Saha,et al.  A study of degradation of cellulosic insulation materials in a power transformer. Part 2: tensile strength of cellulose insulation paper , 1995 .

[5]  J. J. Kelly Transformer Fault Diagnosis by Dissolved-Gas Analysis , 1980, IEEE Transactions on Industry Applications.

[6]  A. Asanov,et al.  A Comparison of Fluorescence Inner-Filter Effects for Different Cell Configurations , 1998 .

[7]  Ashok Kumar Mishra,et al.  Recent developments in multi-component synchronous fluorescence scan analysis , 2002 .

[8]  Tapan Kumar Saha,et al.  Investigating the effects of oxidation and thermal degradation on electrical and chemical properties of power transformers insulation , 1999 .

[9]  A. Mishra,et al.  Concentration dependent red shift: qualitative and quantitative investigation of motor oils by synchronous fluorescence scan. , 2001, Talanta.

[10]  D. Patra,et al.  Excitation Emission Matrix Spectral Subtraction Fluorescence to Check Adulteration of Petrol by Kerosene , 2001 .

[11]  Diana C.S. Azevedo,et al.  Thermo-Oxidative Stability of Mineral Naphthenic Insulating Oils: Combined Effect of Antioxidants and Metal Passivator , 2004 .

[12]  Evaluation of modifications of the simple spectrofluorometry method for estimating petroleum hydrocarbon levels in fresh and waste water samples , 1992 .

[13]  J. Lloyd,et al.  Synchronized Excitation of Fluorescence Emission Spectra , 1971 .

[14]  Graham Williams,et al.  Conference on Electrical Insulation and Dielectric Phenomena , 1982, IEEE Transactions on Electrical Insulation.

[15]  N. E. Frost,et al.  Investigation into the effect of transformer oil on polymers , 1996 .

[16]  A. Mishra,et al.  Effect of sample geometry on synchronous fluorimetric analysis of petrol, diesel, kerosene and their mixtures at higher concentration , 2000 .

[17]  J. Rungis,et al.  Electrical insulating oils. I . Characterization and pre-treatment of new transformer oils , 1995 .

[18]  E. Crisafi,et al.  Monitoring of petroleum hydrocarbon pollution in surface waters by a direct comparison of fluorescence spectroscopy and remote sensing techniques , 1994 .

[19]  L. McGown,et al.  Fluorescence Studies of Complex Coal Liquid Samples Using the Lifetime Synchronous Spectrum (LiSS) , 1995 .

[20]  I. Soutar,et al.  Identification of crude oils by synchronous excitation spectrofluorimetry , 1976 .