Measuring shoulder external and internal rotation strength and range of motion: comprehensive intra-rater and inter-rater reliability study of several testing protocols.

BACKGROUND Shoulder range of motion (ROM) and strength measurements are imperative in the clinical assessment of the patient's status and progression over time. The method and type of assessment varies among clinicians and institutions. No comprehensive study to date has examined the reliability of a variety of procedures based on different testing equipment and specific patient or shoulder position. The purpose of this study was to establish absolute and relative reliability for several procedures measuring the rotational shoulder ROM and strength into internal (IR) and external (ER) rotation strength. METHODS Thirty healthy individuals (15 male, 15 female), with a mean age of 22.1 ± 1.4 years, were examined by 2 examiners who measured ROM with a goniometer and inclinometer and isometric strength with a hand-held dynamometer (HHD) in different patient and shoulder positions. Relative reliability was determined by intraclass correlation coefficients (ICC). Absolute reliability was quantified by standard error of measurement (SEM) and minimal detectable change (MDC). Systematic differences across trials or between testers, as well as differences among similar measurements under different testing circumstances, were analyzed with dependent t tests or repeated-measures analysis of variance in case of 2 or more than 2 conditions, respectively. RESULTS Reliability was good to excellent for IR and ER ROM and isometric strength measurements, regardless of patient or shoulder position or equipment used (ICC, 0.85-0.99). For some of the measurements, systematic differences were found across trials or between testers. The patient's position and the equipment used resulted in different outcome measures. CONCLUSIONS All procedures examined showed acceptable reliability for clinical use. However, patient position and equipment might influence the results.

[1]  Lauren Beaupre,et al.  Evaluating change in clinical status: reliability and measures of agreement for the assessment of glenohumeral range of motion. , 2010, North American journal of sports physical therapy : NAJSPT.

[2]  S. Magnusson,et al.  Shoulder rotational profiles in young healthy elite female and male badminton players , 2014, Scandinavian journal of medicine & science in sports.

[3]  Glenn S Fleisig,et al.  Correlation of Glenohumeral Internal Rotation Deficit and Total Rotational Motion to Shoulder Injuries in Professional Baseball Pitchers , 2011, The American journal of sports medicine.

[4]  J. M. Rothstein,et al.  Goniometric Reliability in a Clinical Setting , 1983 .

[5]  Joo Han Oh,et al.  Within-day reliability of shoulder range of motion measurement with a smartphone. , 2012, Manual therapy.

[6]  J. Weir Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. , 2005, Journal of strength and conditioning research.

[7]  Ralf Dresner,et al.  Health Measurement Scales A Practical Guide To Their Development And Use , 2016 .

[8]  Leslie G. Portney Dpt PhD Fapta,et al.  Foundations of Clinical Research: Applications to Practice , 2015 .

[9]  M. Kolber,et al.  The reliability of hand-held dynamometry in measuring isometric strength of the shoulder internal and external rotator musculature using a stabilization device , 2007, Physiotherapy theory and practice.

[10]  A. Boon,et al.  Manual scapular stabilization: its effect on shoulder rotational range of motion. , 2000, Archives of physical medicine and rehabilitation.

[11]  Jean-Sébastien Roy,et al.  The concurrent validity of a hand-held versus a stationary dynamometer in testing isometric shoulder strength. , 2009, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[12]  T. Ellenbecker,et al.  Assessment of shoulder strength in professional baseball pitchers. , 2000, The Journal of orthopaedic and sports physical therapy.

[13]  Andrew R Karduna,et al.  Internal and external rotation of the shoulder: effects of plane, end-range determination, and scapular motion. , 2005, Journal of shoulder and elbow surgery.

[14]  René Fejer,et al.  Hand‐held Dynamometry Correlation With the Gold Standard Isokinetic Dynamometry: A Systematic Review , 2011, PM & R : the journal of injury, function, and rehabilitation.

[15]  B. Morrey,et al.  A profile of glenohumeral internal and external rotation motion in the uninjured high school baseball pitcher, part I: motion. , 2011, Journal of athletic training.

[16]  M. Kolber,et al.  The reliability and minimal detectable change of shoulder mobility measurements using a digital inclinometer , 2011, Physiotherapy theory and practice.

[17]  Emiel van Trijffel,et al.  Inter-rater reliability for measurement of passive physiological range of motion of upper extremity joints is better if instruments are used: a systematic review. , 2010, Journal of physiotherapy.

[18]  P. Krustrup,et al.  Street football is a feasible health‐enhancing activity for homeless men: Biochemical bone marker profile and balance improved , 2014, Scandinavian journal of medicine & science in sports.

[19]  M. Mullaney,et al.  Reliability of shoulder range of motion comparing a goniometer to a digital level , 2010, Physiotherapy theory and practice.

[20]  H. Rüdiger,et al.  Measurements of shoulder mobility by patient and surgeon correlate poorly: a prospective study. , 2008, Journal of shoulder and elbow surgery.

[21]  Mathias Kluge,et al.  Rehabilitation Research Principles And Applications , 2016 .

[22]  Jay Smith,et al.  Measuring shoulder internal rotation range of motion: a comparison of 3 techniques. , 2002, Archives of physical medicine and rehabilitation.

[23]  Frank E Harrell,et al.  Preseason Shoulder Strength Measurements in Professional Baseball Pitchers , 2010, The American journal of sports medicine.

[24]  C. Terwee,et al.  When to use agreement versus reliability measures. , 2006, Journal of clinical epidemiology.

[25]  R. Herbert,et al.  Does hand-behind-back range of motion accurately reflect shoulder internal rotation? , 2006, Journal of shoulder and elbow surgery.

[26]  K. Wilk,et al.  Glenohumeral Internal Rotation Measurements Differ Depending on Stabilization Techniques , 2009, Sports health.

[27]  M. Kolber,et al.  The reliability and concurrent validity of scapular plane shoulder elevation measurements using a digital inclinometer and goniometer , 2012, Physiotherapy theory and practice.

[28]  J M Rothstein,et al.  Goniometric reliability in a clinical setting. Shoulder measurements. , 1987, Physical therapy.

[29]  A profile of glenohumeral internal and external rotation motion in the uninjured high school baseball pitcher, part II: strength. , 2011 .

[30]  M. Kolber,et al.  The reliability, minimal detectable change and construct validity of a clinical measurement for identifying posterior shoulder tightness. , 2010, North American journal of sports physical therapy : NAJSPT.

[31]  M E Cohen,et al.  Relationship between two measures of upper extremity strength: manual muscle test compared to hand-held myometry. , 1992, Archives of physical medicine and rehabilitation.

[32]  B. Riemann,et al.  Hand-held dynamometer testing of the internal and external rotator musculature based on selected positions to establish normative data and unilateral ratios. , 2010, Journal of shoulder and elbow surgery.

[33]  C. Terwee,et al.  Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer , 2004, BMC musculoskeletal disorders.

[34]  P. McNair,et al.  Reliability of a new hand-held dynamometer in measuring shoulder range of motion and strength. , 2011, Manual therapy.

[35]  K. Cook,et al.  The relationship among strength and mobility measures and self-report outcome scores in persons after rotator cuff repair surgery: impairment measures are not enough. , 2005, Journal of shoulder and elbow surgery.

[36]  G. Murrell,et al.  Reliability of 3 methods for assessing shoulder strength. , 2002, Journal of shoulder and elbow surgery.

[37]  Ellen Shanley,et al.  Changes in passive range of motion and development of glenohumeral internal rotation deficit (GIRD) in the professional pitching shoulder between spring training in two consecutive years. , 2012, Journal of shoulder and elbow surgery.