Performance of microbolometer focal plane arrays under varying pressure

In this letter, we present a study of imaging using a 128/spl times/128-pixel microbolometer focal plane array (FPA) under varying pressure conditions from 10/sup -5/ torr to the ambient. We have employed bulk micromachining in the fabrication of FPA to reduce the thermal conduction through the air-gap between the membrane and the substrate of the microbolometers. It was found that an image of a soldering iron (200/spl deg/C) was clearly visible even at the ambient pressure. However, at ambient pressure, the increased in thermal conductance resulted in a reduction of contrast of the image compared to the ones obtained at low pressure. The results suggest the possibility of operation of uncooled FPA's under ambient pressure by proper design of the microbolometer structure.

[1]  T. Tanaka,et al.  Infrared focal plane array incorporating silicon IC process compatible bolometer , 1996 .

[2]  G. Stemme,et al.  Thermal characterization of surface-micromachined silicon nitride membranes for thermal infrared detectors , 1997 .

[3]  K. Wise,et al.  A silicon-thermopile-based infrared sensing array for use in automated manufacturing , 1986, IEEE Transactions on Electron Devices.

[4]  Christer Jansson,et al.  Theoretical analysis of pulse bias heating of resistance bolometer infrared detectors and effectiveness of bias compensation , 1995, Optics & Photonics.

[5]  Gamani Karunasiri,et al.  On-chip compensation of self-heating effects in microbolometer infrared detector arrays , 1998 .

[6]  A. Peczalski,et al.  Analysis of noise margin and speed of GaAs MESFET DCFL using UM-SPICE , 1986, IEEE Transactions on Electron Devices.

[7]  K. Liddiard Thin-film resistance bolometer IR detectors—II , 1984 .

[8]  Gu Xu,et al.  Extraction of thermal parameters of microbolometer infrared detectors using electrical measurement , 1998, Optics & Photonics.

[9]  Daniel F. Murphy,et al.  Microbolometer uncooled infrared camera with 20-mK NETD , 1998, Defense, Security, and Sensing.

[10]  K. Ping,et al.  Design considerations of metal-film bolometer with micromachined floating membrane , 1992 .

[11]  Gamani Karunasiri,et al.  Determination of thermal parameters of microbolometers using a single electrical measurement , 1998 .

[12]  Geoffrey Duxbury,et al.  Fundamentals of Infrared Detector Operation and Testing , 1992 .

[13]  R. A. Wood,et al.  Uncooled thermal imaging with monolithic silicon focal planes , 1993, Optics & Photonics.

[14]  A. S. Jensen,et al.  Limitations to room-temperature IR imaging systems , 1993, Optics & Photonics.