Semiautomatic contour detection in ultrasound M-mode images.

We have developed a method for semiautomatic contour detection in M-mode images. The method combines tissue Doppler and grey-scale data. It was used to detect: 1. the left endocardium of the septum, the endocardium and epicardium of the posterior wall in 16 left ventricular short-axis M-modes, and 2. the mitral ring in 38 anatomical M-modes extracted pair-wise in 19 apical four-chamber cine-loops (healthy subjects). We validated the results by comparing the computer-generated contours with contours manually outlined by four echocardiographers. For all boundaries, the average distance between the computer-generated contours and the manual outlines was smaller than the average distance between the manual outlines. We also calculated left ventricular wall thickness and diameter at end-diastole and end-systole and lateral and septal mitral ring excursions, and found, on average, clinically negligible differences between the computer-generated indices and the same indices based on manual outlines (0.8-1.8 mm). The results were also within published normal values. In conclusion, this initial study showed that it was feasible in a robust and efficient manner to detect continuous wall boundaries in M-mode images so that tracings of left ventricular wall thickness, diameter and long axis could be derived.

[1]  K Isaaz,et al.  Quantitation of the motion of the cardiac base in normal subjects by Doppler echocardiography. , 1993, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[2]  Nathaniel Reichek,et al.  Computerized M‐mode Echocardiographic Analysis of Left Ventricular Dysfunction in Cardiac Amyloid , 1982, Circulation.

[3]  R. Bellman Dynamic programming. , 1957, Science.

[4]  Stephen E. Brown,et al.  Echocardiographic Detection of Coronary Artery Disease During Dobutamine Infusion , 1991, Circulation.

[5]  P. Rigo,et al.  Identification of viable myocardium by echocardiography during dobutamine infusion in patients with myocardial infarction after thrombolytic therapy: comparison with positron emission tomography. , 1990, Journal of the American College of Cardiology.

[6]  M A García-Fernández,et al.  Doppler tissue imaging. , 2001, Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology.

[7]  C. Jones,et al.  Functional importance of the long axis dynamics of the human left ventricle. , 1990, British heart journal.

[8]  N Reichek,et al.  Echocardiographic Determination of Left Ventricular Mass in Man: Anatomic Validation of the Method , 1977, Circulation.

[9]  B. Wandt,et al.  Left ventricular contraction pattern changes with age in normal adults. , 1998, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[10]  G R Sutherland,et al.  Doppler tissue imaging: myocardial wall motion velocities in normal subjects. , 1995, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[11]  L. Erhardt,et al.  Left ventricular atrioventricular plane displacement: an echocardiographic technique for rapid assessment of prognosis in heart failure. , 1997, Heart.

[12]  R. B. Sinclair,et al.  Computing in echocardiography. , 1983, Progress in cardiovascular diseases.

[13]  M Unser,et al.  Automated extraction of serial myocardial borders from M-mode echocardiograms. , 1989, IEEE transactions on medical imaging.

[14]  Laurent D. Cohen,et al.  Finite-Element Methods for Active Contour Models and Balloons for 2-D and 3-D Images , 1993, IEEE Trans. Pattern Anal. Mach. Intell..

[15]  B. Wandt,et al.  Reduced left ventricular relaxation velocity after acute myocardial infarction. , 1998, Clinical Physiology.

[16]  S. Lundbäck,et al.  Cardiac pumping and function of the ventricular septum. , 1986, Acta physiologica Scandinavica. Supplementum.

[17]  A. DeMaria,et al.  Recommendations Regarding Quantitation in M-Mode Echocardiography: Results of a Survey of Echocardiographic Measurements , 1978, Circulation.

[18]  G R Sutherland,et al.  Color Doppler myocardial imaging: a new technique for the assessment of myocardial function. , 1994, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[19]  R. Devereux Echocardiography: state of the art--1984. , 1984, The Cardiology.

[20]  N. Schiller,et al.  Descent of the base of the left ventricle: an echocardiographic index of left ventricular function. , 1989, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[21]  B. Wranne,et al.  Assessment of left ventricular diastolic function from mitral annulus motion, a comparison with pulsed Doppler measurements in patients with heart failure. , 1996, Clinical physiology.

[22]  M. Uematsu,et al.  Myocardial velocity gradient as a new indicator of regional left ventricular contraction: detection by a two-dimensional tissue Doppler imaging technique. , 1995, Journal of the American College of Cardiology.

[23]  W. McDicken,et al.  Color Doppler myocardial imaging , 1994 .

[24]  G. Aurigemma,et al.  Geometric changes allow normal ejection fraction despite depressed myocardial shortening in hypertensive left ventricular hypertrophy. , 1995, Journal of the American College of Cardiology.

[25]  K. Kristoffersen,et al.  Autocorrelation techniques in color flow imaging: signal model and statistical properties of the autocorrelation estimates , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  W. McDicken,et al.  Myocardial velocity gradients detected by Doppler imaging. , 1994, The British journal of radiology.

[27]  Yongmin Kim,et al.  A methodology for evaluation of boundary detection algorithms on medical images , 1997, IEEE Transactions on Medical Imaging.

[28]  M. Alam,et al.  Longitudinal systolic shortening of the left ventricle: an echocardiographic study in subjects with and without preserved global function. , 1992, Clinical physiology.

[29]  D N Firmin,et al.  Assessment of regional left ventricular long‐axis motion with MR velocity mapping in healthy subjects , 1994, Journal of magnetic resonance imaging : JMRI.

[30]  D. Adam,et al.  Automatic ventricular cavity boundary detection from sequential ultrasound images using simulated annealing. , 1989, IEEE transactions on medical imaging.

[31]  Ramesh C. Jain,et al.  Using Dynamic Programming for Solving Variational Problems in Vision , 1990, IEEE Trans. Pattern Anal. Mach. Intell..

[32]  C. Kasai,et al.  Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique , 1985, IEEE Transactions on Sonics and Ultrasonics.