A meta-analysis of outcomes of endovascular abdominal aortic aneurysm repair in patients with hostile and friendly neck anatomy.

BACKGROUND An increasing number of abdominal aortic aneurysms with unfavorable proximal neck anatomy are treated with standard endograft devices. Skepticism exists with regard to the safety and efficacy of this practice. METHODS A systematic review of the literature was undertaken to identify all studies comparing the outcomes of endovascular aneurysm repair (EVAR) in patients with hostile and friendly infrarenal neck anatomy. Hostile neck conditions were defined as conditions that were not consistent with the instructions for use of the endograft devices employed in the selected studies. Outcome data were pooled, and combined overall effect sizes were calculated using fixed or random effects models. RESULTS Seven observational studies reporting on 1559 patients (hostile anatomy group, 714 patients; friendly anatomy group, 845 patients) were included. Patients with hostile anatomy required an increased number of adjunctive procedures to achieve proximal seal compared with patients with friendly anatomy (odds ratio [OR], 3.050; 95% confidence interval [CI], 1.884-4.938). Although patients with unfavorable neck anatomy had an increased risk of developing 30-day morbidity (OR, 2.278; 95% CI, 1.025-5.063), no significant differences in the incidence of type I endoleak and reintervention rates within 30 days of treatment between the two groups were identified (OR, 2.467 and 1.082; 95% CI, 0.562-10.823 and 0.096-12.186). Patients with hostile anatomy had a fourfold increased risk of developing type I endoleak (OR, 4.563; 95% CI, 1.430-14.558) and a ninefold increased risk of aneurysm-related mortality within 1 year of treatment (OR, 9.378; 95% CI, 1.595-55.137). CONCLUSIONS Insufficient high-level evidence for or against performing standard EVAR in patients with hostile neck anatomy exists. Our analysis suggests EVAR should be cautiously used in patients with anatomic neck constraints.

[1]  N. Laird,et al.  Meta-analysis in clinical trials. , 1986, Controlled clinical trials.

[2]  R. Green,et al.  Endovascular grafting in patients with short proximal necks: an analysis of short-term results. , 2000, Cardiovascular surgery.

[3]  J. Buth,et al.  Influence of Severe Infrarenal Aortic Neck Angulation on Complications at the Proximal Neck following Endovascular AAA Repair: A EUROSTAR Study , 2007, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[4]  G. Antoniou,et al.  Early results of the Endurant endograft system in patients with friendly and hostile infrarenal abdominal aortic aneurysm anatomy. , 2011, Journal of vascular surgery.

[5]  R. Lovegrove,et al.  A meta‐analysis of 21 178 patients undergoing open or endovascular repair of abdominal aortic aneurysm , 2008, The British journal of surgery.

[6]  G. LaMuraglia,et al.  Outcomes following endovascular abdominal aortic aneurysm repair (EVAR): an anatomic and device-specific analysis. , 2008, Journal of vascular surgery.

[7]  Aravinda Nanjundappa,et al.  The correlation of aortic neck length to early and late outcomes in endovascular aneurysm repair patients. , 2009, Journal of vascular surgery.

[8]  B. Sonesson,et al.  Evar and Complex Anatomy: An Update on Fenestrated and Branched Stent Grafts , 2008, Scandinavian journal of surgery : SJS : official organ for the Finnish Surgical Society and the Scandinavian Surgical Society.

[9]  J. V. van Herwaarden,et al.  Final results of the prospective European trial of the Endurant stent graft for endovascular abdominal aortic aneurysm repair. , 2011, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[10]  P. Tugwell,et al.  The Newcastle-Ottawa Scale (NOS) for Assessing the Quality of Nonrandomised Studies in Meta-Analyses , 2014 .

[11]  G. Copeland,et al.  Early Results of Fenestrated Endovascular Repair of Juxtarenal Aortic Aneurysms in the United Kingdom , 2012, Circulation.

[12]  N. Troisi,et al.  Evaluation of the Endurant stent graft under instructions for use vs off-label conditions for endovascular aortic aneurysm repair. , 2011, Journal of vascular surgery.

[13]  S. Muluk,et al.  Does hostile neck anatomy preclude successful endovascular aortic aneurysm repair? , 2003, Journal of vascular surgery.

[14]  G. L. Moneta Endovascular versus Open Repair of Abdominal Aortic Aneurysm , 2010 .

[15]  G. Antoniou,et al.  Chimney technique in the endovascular management of complex aortic disease , 2012, Vascular.

[16]  Robert Morgan,et al.  Outcomes of Endovascular Abdominal Aortic Aneurysm Repair in Patients with Hostile Neck Anatomy , 2006, CardioVascular and Interventional Radiology.

[17]  F. Moll,et al.  Severe proximal aneurysm neck angulation: early results using the Endurant stentgraft system. , 2011, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[18]  T. Huber Outcomes Following Endovascular vs Open Repair of Abdominal Aortic Aneurysm: A Randomized Trial , 2010 .

[19]  R. Fairman,et al.  Impact of exclusion criteria on patient selection for endovascular abdominal aortic aneurysm repair. , 2001, Journal of vascular surgery.

[20]  S. Money,et al.  Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repair. , 2002, Journal of vascular surgery.

[21]  D. Raithel,et al.  Experience with the Endologix Powerlink endograft in endovascular repair of abdominal aortic aneurysms with short and angulated necks. , 2008, Perspectives in vascular surgery and endovascular therapy.

[22]  R. Fairman,et al.  Midterm pivotal trial results of the Talent Low Profile System for repair of abdominal aortic aneurysm: analysis of complicated versus uncomplicated aortic necks. , 2004, Journal of vascular surgery.

[23]  A. AbuRahma,et al.  Clinical outcomes for hostile versus favorable aortic neck anatomy in endovascular aortic aneurysm repair using modular devices. , 2010, Journal of vascular surgery.

[24]  K. Hoshina,et al.  Middle-term results of endovascular aneurysm repair in Japan: does intraoperative endovascular management against the hostile aneurysmal neck prevent the proximal type I endoleak? , 2011, International angiology : a journal of the International Union of Angiology.

[25]  B. Rubin,et al.  Effect of challenging neck anatomy on mid-term migration rates in AneuRx endografts. , 2006, Journal of vascular surgery.

[26]  C. Zarins,et al.  Reporting standards for endovascular aortic aneurysm repair. , 2002, Journal of vascular surgery.

[27]  N. Troisi,et al.  Endurant Stent-Graft: A 2-Year, Single-Center Experience with a New Commercially Available Device for the Treatment of Abdominal Aortic Aneurysms , 2010, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[28]  P. Peduzzi,et al.  Outcomes following endovascular vs open repair of abdominal aortic aneurysm: a randomized trial. , 2009, JAMA.

[29]  P. Dagnelie,et al.  Influence of Infrarenal Neck Length on Outcome of Endovascular Abdominal Aortic Aneurysm Repair , 2006, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[30]  B. Hopkinson,et al.  The Aorfix Stent-Graft to Treat Infrarenal Abdominal Aortic Aneurysms with Angulated Necks and/or Tortuous Iliac Arteries: Midterm Results , 2009, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[31]  G. Moneta Endovascular abdominal aortic aneurysm repair: Long-term outcome measures in patients at high-risk for open surgery , 2008 .

[32]  S. Muluk,et al.  Challenging neck anatomy is associated with need for intraoperative endovascular adjuncts during endovascular aortic aneurysm repair (EVAR). , 2011, Annals of vascular surgery.

[33]  D. Altman,et al.  Measuring inconsistency in meta-analyses , 2003, BMJ : British Medical Journal.