Functional avoidance of lung in plan optimization with an aperture-based inverse planning system.

PURPOSE To implement SPECT-based optimization in an anatomy-based aperture inverse planning system for the functional avoidance of lung in thoracic irradiation. MATERIAL AND METHODS SPECT information has been introduced as a voxel-by-voxel modulation of lung importance factors proportionally to the local perfusion count. Fifteen cases of lung cancer have been retrospectively analyzed by generating angle-optimized non-coplanar plans, comparing a purely anatomical approach and our functional approach. Planning target volume coverage and lung sparing have been compared. Statistical significance was assessed by a Wilcoxon matched pairs test. RESULTS For similar target coverage, perfusion-weighted volume receiving 10 Gy was reduced by a median of 2.2% (p=0.022) and mean perfusion-weighted lung dose, by a median of 0.9 Gy (p=0.001). A separate analysis of patients with localized or non-uniform hypoperfusion could not show which would benefit more from SPECT-based treatment planning. Redirection of dose sometimes created overdosage regions in the target volume. Plans consisted of a similar number of segments and monitor units. CONCLUSIONS Angle optimization and SPECT-based modulation of importance factors allowed for functional avoidance of the lung while preserving target coverage. The technique could be also applied to implement PET-based modulation inside the target volume, leading to a safer dose escalation.

[1]  Luc Beaulieu,et al.  Simultaneous optimization of beam orientations, wedge filters and field weights for inverse planning with anatomy-based MLC fields. , 2004 .

[2]  Søren M Bentzen,et al.  Theragnostic imaging for radiation oncology: dose-painting by numbers. , 2005, The Lancet. Oncology.

[3]  Fang-Fang Yin,et al.  A methodology for using SPECT to reduce intensity-modulated radiation therapy (IMRT) dose to functioning lung. , 2006, International journal of radiation oncology, biology, physics.

[4]  Ursula Nestle,et al.  Practical integration of [18F]-FDG-PET and PET-CT in the planning of radiotherapy for non-small cell lung cancer (NSCLC): the technical basis, ICRU-target volumes, problems, perspectives. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  A. Boyer,et al.  Inverse planning for functional image-guided intensity-modulated radiation therapy. , 2002, Physics in medicine and biology.

[6]  Jean-François Aubry,et al.  Multiobjective optimization with a modified simulated annealing algorithm for external beam radiotherapy treatment planning. , 2006, Medical physics.

[7]  Peter A Balter,et al.  Reduction of normal lung irradiation in locally advanced non-small-cell lung cancer patients, using ventilation images for functional avoidance. , 2007, International journal of radiation oncology, biology, physics.

[8]  R. Ireland,et al.  Functional image-based radiotherapy planning for non-small cell lung cancer: A simulation study. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  Thomas Guerrero,et al.  Preserving functional lung using perfusion imaging and intensity-modulated radiation therapy for advanced-stage non-small cell lung cancer. , 2007, International journal of radiation oncology, biology, physics.

[10]  Joos V Lebesque,et al.  Optimizing radiation treatment plans for lung cancer using lung perfusion information. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  Lawrence B Marks,et al.  Incorporation of functional imaging data in the evaluation of dose distributions using the generalized concept of equivalent uniform dose , 2004, Physics in medicine and biology.

[12]  Xavier Geets,et al.  Adaptive biological image-guided IMRT with anatomic and functional imaging in pharyngo-laryngeal tumors: impact on target volume delineation and dose distribution using helical tomotherapy. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  X Allen Li,et al.  BGRT: biologically guided radiation therapy-the future is fast approaching! , 2007, Medical physics.

[14]  H. Thierens,et al.  [18F]fluoro-deoxy-glucose positron emission tomography ([18F]FDG-PET) voxel intensity-based intensity-modulated radiation therapy (IMRT) for head and neck cancer. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  Frédéric Beaulieu,et al.  Automatic generation of anatomy-based MLC fields in aperture-based IMRT. , 2004, Medical physics.

[16]  T. Schultheiss,et al.  Radiation dose-volume effects in the spinal cord. , 2010, International journal of radiation oncology, biology, physics.

[17]  Michael Lock,et al.  Prediction of radiation pneumonitis by dose - volume histogram parameters in lung cancer--a systematic review. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[18]  M. Martel,et al.  Radiation dose-volume effects in the lung. , 2010, International journal of radiation oncology, biology, physics.

[19]  J A Purdy,et al.  Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC) , 1999, International journal of radiation oncology, biology, physics.

[20]  D. Tremblay,et al.  Dose escalation in the radiotherapy of non-small-cell lung cancer with aperture-based intensity modulation and photon beam energy optimization for non-preselected patients. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[21]  A H Baydush,et al.  Feasibility of optimizing the dose distribution in lung tumors using fluorine-18-fluorodeoxyglucose positron emission tomography and single photon emission computed tomography guided dose prescriptions. , 2004, Medical physics.

[22]  J. Bedford,et al.  Effective avoidance of a functional spect-perfused lung using intensity modulated radiotherapy (IMRT) for non-small cell lung cancer (NSCLC): an update of a planning study. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[23]  M T Munley,et al.  Incorporation of functional status into dose-volume analysis. , 1999, Medical physics.

[24]  Frederic Courbon,et al.  The incorporation of SPECT functional lung imaging into inverse radiotherapy planning for non-small cell lung cancer. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[25]  J. Bedford,et al.  A potential to reduce pulmonary toxicity: the use of perfusion SPECT with IMRT for functional lung avoidance in radiotherapy of non-small cell lung cancer. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[26]  C C Ling,et al.  Towards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality. , 2000, International journal of radiation oncology, biology, physics.

[27]  Philippe Lambin,et al.  Effects of radiotherapy planning with a dedicated combined PET-CT-simulator of patients with non-small cell lung cancer on dose limiting normal tissues and radiation dose-escalation: a planning study. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[28]  Cristian Lorenz,et al.  Impact of four-dimensional computed tomography pulmonary ventilation imaging-based functional avoidance for lung cancer radiotherapy. , 2011, International journal of radiation oncology, biology, physics.

[29]  C. Ramsey,et al.  Dosimetric verification of two commercially available three-dimensional treatment planning systems using the TG 23 test package. , 1999, Medical physics.

[30]  D. Tremblay,et al.  Optimization of photon beam energy in aperture‐based inverse planning , 2009, Journal of applied clinical medical physics.