A Study of the Display Pixel-Based Focusing Method in Ultrasound Imaging

This paper presents a new beamforming technique, in which ultrasound waves are focused at the display pixels on the Cartesian coordinates, rather than sampling points located on the uniformly-separated scanlines on either the polar or Cartesian coordinates. Consequently, this method does not require a digital scan converter (DSC) and therefore completely eliminates the distortions due to the DSC. A new imaging system based on the proposed method is also presented, which is advantageous over conventional systems in hardware complexity, especially when high-density imaging is required. The new method can also be used effectively to achieve high frame rates for real-time 3D imaging and cardiac applications. To verify the proposed method, we modified a commercial ultrasound scanner and performed experiments with a 3.5MHz convex array and a 7.5MHz linear array. The experimental results with in vivo and in vitro data show that the proposed technique provides much smoother and finer images than the conventional dynamic focusing methods.

[1]  G.R. Lockwood,et al.  Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  W.D. O'Brien,et al.  Synthetic aperture techniques with a virtual source element , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Jian-yu Lu,et al.  2D and 3D high frame rate imaging with limited diffraction beams , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  M. O'Donnell,et al.  Synthetic aperture imaging for small scale systems , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  S. B. Park,et al.  A new digital phased array system for dynamic focusing and steering with reduced sampling rate. , 1990, Ultrasonic imaging.

[6]  Song Bai Park,et al.  Analysis of a Scan Conversion Algorithm for a Real-Time Sector Scanner , 1986, IEEE Transactions on Medical Imaging.

[7]  R. Mucci A comparison of efficient beamforming algorithms , 1984 .

[8]  M. Bae,et al.  A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systems. , 2000, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[9]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  G. Trahey,et al.  Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities. II. Effects of and correction for motion , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. II. Parallel processing and image display , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  Jonathan Ophir,et al.  Moiré Undersampling Artifacts in Digital Ultrasound Images , 1982 .

[13]  Minho Lee,et al.  New continuous dynamic focusing technique in ultrasound imaging , 1985 .

[14]  M. O’Donnell,et al.  Adaptive multi-element synthetic aperture imaging with motion and phase aberration correction , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  M O'Donnell,et al.  Improved detectability with blocked element compensation. , 1994, Ultrasonic imaging.

[16]  G.E. Trahey,et al.  Parallel processing techniques for the speckle brightness phase aberration correction algorithm , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  D. L. Hykes,et al.  Ultrasound Physics and Instrumentation , 1985 .

[18]  J. Ophir,et al.  Digital scan converters in diagnostic ultrasound imaging , 1979, Proceedings of the IEEE.

[19]  James A. Zagzebski,et al.  Essentials Of Ultrasound Physics , 1996 .

[20]  D E Robinson,et al.  Interpolation scan conversion in pulse-echo ultrasound. , 1982, Ultrasonic imaging.

[21]  M. O'Donnell Efficient parallel receive beam forming for phased array imaging using phase rotation (medical US application) , 1990, IEEE Symposium on Ultrasonics.

[22]  K. W. Rigby,et al.  Efficient parallel adaptive aberration correction , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.