The determination of trace metal pollutants in environmental matrices using ion chromatography.

A review is presented detailing the development of ion chromatography (IC) as a selective analytical tool for the determination of toxic metals and their organic species in many environmental sample matrices. A brief outline of ion chromatographic principles, together with an overview of the stationary phases used to separate metals, namely ion exchangers, modified ion pair sorbents and chelating ion exchangers, and the methods for detecting metal ions including hyphenation with spectroscopy and sample preparation schemes are also given, prior to a critical examination of developed methods for various metals including arsenic, chromium, cadmium, lead, mercury, beryllium, aluminium and uranium since 1990.

[1]  M. C. Bruzzoniti,et al.  Metal Species Determination by Ion Chromatography , 2001 .

[2]  C. Lucy,et al.  Chromatographic determination of metal-EDTA complexes with postcolumn detection using fluorescent ternary complexes , 1995 .

[3]  J. Glennon,et al.  Selective preconcentration and ion chromatography of trace lead(II) in environmental samples using a porous graphitic carbon column , 1999 .

[4]  J. Creed,et al.  Extraction and detection of arsenicals in seaweed via accelerated solvent extraction with ion chromatographic separation and ICP-MS detection , 2001, Fresenius' journal of analytical chemistry.

[5]  M. Pantsar-Kallio,et al.  Speciation of chromium in aquatic samples by coupled column ion chromatography-inductively coupled plasma-mass spectrometry , 1996 .

[6]  O. Shpigun,et al.  Ion-Pair Chromatography of Metal Complexes of Unithiol in the Presence of Quaternary Phosphonium Salts , 2001 .

[7]  M. de la Guardia,et al.  Chromium speciation in liquid matrices: a survey of the literature , 2000, Fresenius' journal of analytical chemistry.

[8]  R. M. Izatt,et al.  Complexing and Chelating Agents Immobilized on Silica Gel and Related Materials and Their Application for Sorption of Inorganic Species , 1994 .

[9]  M. Martin,et al.  Review of The Heavy Elements: Chemistry, Environmental Impact and Health Effects by J E Fergusson , 1991 .

[10]  J. Riviello,et al.  Chelation ion chromatography as a method for trace elemental analysis in complex environmental and biological samples. , 1990, Analytical chemistry.

[11]  Chuen‐Ying Liu,et al.  Preparation and evaluation of a functionalized polymer-coated silica based sorbent for metal ion separation , 1998 .

[12]  J. Fritz,et al.  Methods for concentrating metal ions prior to analysis by ion chromatography or capillary electrophoresis , 1996 .

[13]  J. Riviello,et al.  New strategies for determination of transition metals by complexation ion-exchange chromatography and post column reaction , 1999 .

[14]  E. Evans,et al.  Determination of actinides in environmental and biological samples using high-performance chelation ion chromatography coupled to sector-field inductively coupled plasma mass spectrometry. , 2001, Journal of chromatography. A.

[15]  P. Coetzee,et al.  Ion Chromatographie Separation and Spectrophotometric Determination of U(IV) and U(VI) , 1992 .

[16]  L. A. D. L. Heras,et al.  Studies on simultaneous separation and determination of lanthanides and actinides by ion chromatography inductively coupled plasma mass spectrometry combined with isotope dilution mass spectrometry , 2002 .

[17]  G. Bonn,et al.  Ion chromatography of transition metals on an iminodiacetic acid bonded stationary phase , 1990 .

[18]  S. Verma,et al.  Trace analysis of heavy metals in groundwater samples by ion chromatography with post-column reaction and ultraviolet-visible detection. , 2000, Journal of chromatography. A.

[19]  B. Fabre,et al.  Ion chromatographic and voltammetric determination of heavy metals in soils. Comparison with atomic emission spectroscopy , 1999 .

[20]  L. Diels,et al.  Characterization of inorganic selenium species by ion chromatography with ICP-MS detection in microbial-treated industrial waste water , 2000 .

[21]  S. Mou,et al.  Improved scheme of chelation ion chromatography with a mixed eluent for the simultaneous analysis of transition metals at microg l(-1) levels. , 2000, Journal of chromatography. A.

[22]  M. Betti,et al.  Ion chromatography inductively coupled plasma mass spectrometry (IC-ICP-MS) and radiometric techniques for the determination of actinides in aqueous leachate solutions from uranium oxide , 2000, Fresenius' journal of analytical chemistry.

[23]  A. Martín‐Esteban,et al.  Determination of trace metals in waters and compost by on-line precipitation coupled to flame atomic absorption spectrophotometry or ion chromatography. , 1999, Talanta.

[24]  B. Rudenko,et al.  Ion chromatographic determination of beryllium in rock and waste waters with a chelating sorbent and conductimetric detection , 1995 .

[25]  B. Do,et al.  Speciation of arsenic and selenium compounds by ion-pair reversed-phase chromatography with electrothermic atomic absorption spectrometry. Application of experimental design for chromatographic optimisation. , 2001, Journal of chromatography. A.

[26]  Phil Jones Major sensitivity improvements in ion chromatography determinations involving post-column spectrophotometric reaction detectors through elimination of pump noise using a dual wavelength monitoring procedure , 2000 .

[27]  B. Paull,et al.  A comparative study of the metal selective properties of chelating dye impregnated resins for the ion chromatographic separation of trace metals , 1996 .

[28]  M. C. Bruzzoniti,et al.  A study of the mechanisms involved in the separation of metal ions with a mixed-bed stationary phase , 2002 .

[29]  J. Reedijk,et al.  Coordination chemistry of chelating resins and ion exchangers , 1984 .

[30]  R. Dahl,et al.  Determination of total chromium in phosphate rocks by ion chromatography. , 1999, Journal of chromatography. A.

[31]  G. de Gennaro,et al.  Analysis of heavy metals in atmospheric particulate by ion chromatography. , 2000, Journal of chromatography. A.

[32]  B. Paull,et al.  DETERMINATION OF LEAD IN WATER SAMPLES USING ION CHROMATOGRAPHY WITH A XYLENOL ORANGE CONTAINING ELUENT , 2001 .

[33]  D. Wallschläger,et al.  Determination of inorganic selenium speciation in waters by ion chromatography-inductively coupled plasma-mass spectrometry using eluant elimination with a membrane suppressor , 2001 .

[34]  B. Paull,et al.  High-performance chelation ion chromatographic determination of trace metals in coastal sea-water using dye-impregnated resins , 1994 .

[35]  S. Cavalli,et al.  Sample pretreatment by UV photolysis for the ion chromatographic analysis of plant material , 1996 .

[36]  F. D. Snell Photometric and fluorometric methods of analysis: Metals , 1978 .

[37]  D. Polya,et al.  Seasonal Variation of Total Dissolved Arsenic and Arsenic Speciation in A Polluted Surface Waterway , 2003, Environmental geochemistry and health.

[38]  S. Goyal,et al.  Simultaneous determination of arsenite, arsenate, selenite and selenate in waters using suppressed ion chromatography with ultraviolet absorbance detection , 1991 .

[39]  T. Suzuki,et al.  Determination of trace metals in sea-water by inductively coupled plasma mass spectrometry interfaced with an ion chromatographic separation system: effectiveness of nitrilotriacetate chelating resin as the column stationary phase for preconcentration and elimination of matrix effects , 1998 .

[40]  A. Padarauskas,et al.  Ion-pair chromatographic determination of chromium(VI). , 1993, Talanta.

[41]  Phil Jones,et al.  Development of a novel multi-element detection system for trace metal determination based on chemiluminescence after separation by ion chromatography , 1990 .

[42]  J. Caruso,et al.  Inductively coupled plasma mass spectrometric detection for chromatography and capillary electrophoresis. , 1997, Journal of Chromatography A.

[43]  W. Shotyk,et al.  Determination of Cd, Co, Cu, Fe, Mn, Ni and Zn in coral skeletons by chelation ion chromatography , 1995 .

[44]  C. Sarzanini Liquid chromatography: a tool for the analysis of metal species. , 1999, Journal of chromatography. A.

[45]  B. Rudenko,et al.  Determination of aluminium in natural waters by single-column ion chromatography with indirect UV detection , 1995 .

[46]  N. Basta,et al.  Ion Chromatographic Determination of Total Metals in Soils , 1990 .

[47]  M. C. Bruzzoniti,et al.  Electrochemical detection of sulphonated azo dyes and their metal complexes in ion interaction chromatography , 1998 .

[48]  R. Dahl,et al.  Determination of thorium and uranium in nitrophosphate fertilizer solution by ion chromatography , 1995 .

[49]  J. Weiss,et al.  Modern stationary phases for ion chromatography , 2003, Analytical and bioanalytical chemistry.

[50]  M. Pantsar-Kallio,et al.  Speciation of chromium in waste waters by coupled column ion chromatography-inductively coupled plasma mass spectrometry , 1996 .

[51]  D. J. Roberts,et al.  Chromatographic and hyphenated methods for elemental speciation analysis in environmental media. , 1997, Journal of chromatography. A.

[52]  E. Sandell Colorimetric Determination of Traces of Metals , 1944 .

[53]  C. Fu,et al.  Pre-column chelation liquid chromatographic separation and determination of trace V, Cu, Co, Pd, Fe and Ni , 1990 .

[54]  E. Borai,et al.  Monitoring and statistical evaluation of heavy metals in airborne particulates in Cairo, Egypt. , 2001, Journal of chromatography. A.

[55]  M. Rashid,et al.  Determination of heavy metals in air particulate matter by ion chromatography , 1996 .

[56]  P. Nesterenko,et al.  High-Performance Chelation Chromatography of Metal Ions on Sorbents with Grafted Iminodiacetic Acid , 2002 .

[57]  M. Mclaughlin,et al.  Determination of metal--EDTA complexes in soil solution and plant xylem by ion chromatography-electrospray mass spectrometry. , 2001, Environmental science & technology.

[58]  Phil Jones,et al.  Fabrication of an Aurin Tricarboxylic Acid Immobilized Chelating Polymer for the Ion Chromatographic Determination of Trace Metal Ions in Highly Mineralized Waters , 2003 .

[59]  J. Gibson,et al.  The application of fluorescence detection to the determination and speciation of aluminium in soil solutions by ion chromatography , 1991 .

[60]  M. Marina,et al.  The State of the Art of Ligand-Loaded Complexing Resins. Characteristics and Applications , 1994 .

[61]  A. Almgren,et al.  Simultaneous and sensitive analysis of Cu, Ni, Zn, Co, Mn, and Fe in food and biological samples by ion chromatography. , 2002, Journal of agricultural and food chemistry.

[62]  S. Nam,et al.  Direct measurement of trivalent chromium and hexavalent chromium by ion chromatography coupled with end-on-view ICP-AES , 2001 .

[63]  E. Larsen,et al.  Determination of organoarsenic species in marine samples using gradient elution cation exchange HPLC-ICP-MS , 2003 .

[64]  D. Wiederin,et al.  Metal speciation by means of microbore columns with direct-injection nebulization by inductively coupled plasma atomic emission spectroscopy , 1993 .

[65]  E. Mentasti,et al.  Determination and speciation of metals by liquid chromatography , 1997 .

[66]  B. Paull,et al.  Non-trivial temperature effects on the cation exchange chromatography and chelation ion chromatography of metal ions. , 2003, The Analyst.

[67]  N. Avdalović,et al.  Applications of ion chromatography with electrospray mass spectrometric detection to the determination of environmental contaminants in water. , 2002, Journal of chromatography. A.

[68]  P. Haddad,et al.  Determination of trace uranyl in saline samples using chelation ion chromatography , 1998 .

[69]  Ronald E. Majors,et al.  Trends in Sample Preparation , 1992 .

[70]  E. Arar,et al.  Determination of dissolved hexavalent chromium in industrial wastewater effluents by ion chromatography and post-column derivatization with diphenylcarbazide. , 1991, Journal of chromatography.

[71]  B. Jackson,et al.  Trace element speciation in largemouth bass (Micropterus salmoides) from a fly ash settling basin by liquid chromatography-ICP-MS , 2002, Analytical and bioanalytical chemistry.

[72]  Chuen‐Ying Liu,et al.  Determination of vanadium, molybdenum and tungsten in complex matrix samples by chelation ion chromatography and on-line detection with inductively coupled plasma mass spectrometry , 2002 .

[73]  E. Mentasti,et al.  Ion chromatographic separation and on-line cold vapour atomic absorption spectrometric determination of methylmercury, ethylmercury and inorganic mercury , 1994 .

[74]  R. Wennrich,et al.  Determination of Anionic, Neutral, and Cationic Species of Arsenic by Ion Chromatography with ICPMS Detection in Environmental Samples. , 1998, Analytical chemistry.

[75]  A L Linch,et al.  Liquid chromatography. , 1973, Health laboratory science.

[76]  Chuen‐Ying Liu,et al.  γ-Aminobutyrohydroxamate resins as stationary phases of chelation ion chromatography , 1998 .

[77]  S. Hill,et al.  Separation and determination of trace metals in concentrated salt solutions using chelation ion chromatography , 1993 .

[78]  P. Jones THE INVESTIGATION OF ALUMINIUM SPECIATION IN NATURAL AND POTABLE WATERS USING SHORT-COLUMN ION CHROMATOGRAPHY , 1991 .

[79]  B. Wheals,et al.  Reversed-phase ion-pair chromatography with inductively coupled plasma-mass spectrometry detection for the determination of organo-tin compounds in waters , 1997 .

[80]  A. Ammann Speciation of heavy metals in environmental water by ion chromatography coupled to ICP–MS , 2002, Analytical and bioanalytical chemistry.

[81]  M. Trojanowicz,et al.  Flow-injection sample preconcentration for ion-pair chromatography of trace metals in waters. , 2003, Water research.

[82]  S. Yuvaraj,et al.  Determination of hexavalent chromium by on-line dialysis ion chromatography in a matrix of strong colourants and trivalent chromium. , 2003, Journal of chromatography. A.

[83]  M. Pantsar-Kallio,et al.  Simultaneous determination of toxic arsenic and chromium species in water samples by ion chromatography-inductively coupled plasma mass spectrometry , 1997 .

[84]  P. Udén,et al.  Determination of inorganic Hg(II) and organic mercury compounds by ion-pair high-performance liquid chromatography , 1994 .

[85]  C. Cámara Assessment of methods currently used for the determination of Cr and Se species in solutions. , 2000 .

[86]  P. Worsfold,et al.  Analytical perspective. Solid phase techniques for the preconcentration of trace metals from natural waters , 1995 .

[87]  Jian Zheng,et al.  Simultaneous Speciation of Arsenic and Selenium Compounds by ION-Chromatography with Inductively Coupled Plasma Mass Spectrometry as Elemental Specific Detector , 1998 .

[88]  W. Buchberger,et al.  Separation of metal complexes of ethylenediaminetetraacetic acid in environmental water samples by ion chromatography with UV and potentiometric detection , 1991 .

[89]  P. Nesterenko,et al.  Determination of beryllium in a stream sediment by high-performance chelation ion chromatography. , 2000, Journal of chromatography. A.

[90]  R. Caprioli,et al.  Determination of copper, nickel, zinc, cobalt and manganese in seawater by chelation ion chromatography , 1993 .

[91]  P. Haddad Ion chromatography retrospective. , 2001, Analytical chemistry.

[92]  P. Nesterenko,et al.  Dynamic chelation ion chromatography of transition and heavy metal ions using a mobile phase containing 4-chlorodipicolinic acid. , 2002, Journal of chromatography. A.

[93]  H. B. Lim,et al.  SPECIATION AND SEQUENTIAL EXTRACTION OF TRACE METALS IN INCINERATOR FLY ASH USING IC AND ICP-MS , 2002 .

[94]  Z. Rengel,et al.  Arsenic speciation in terrestrial plant material using microwave-assisted extraction, ion chromatography and inductively coupled plasma mass spectrometry , 2003 .

[95]  S. B. Savvin,et al.  Chelating Sorbents in Analytical Chemistry , 1986 .

[96]  H. Tao,et al.  Sensitive determination of three arsenic species in water by ion exclusion chromatography-hydride generation-inductively coupled plasma mass spectrometry , 1999 .

[97]  C. Sarzanini Recent developments in ion chromatography. , 2002, Journal of chromatography. A.

[98]  S. Hill,et al.  High-performance liquid chromatography^ isotope dilution inductively coupled plasma mass spectrometry for speciation studies: an overview , 2000 .

[99]  S. Mou,et al.  Retention behavior of transition metals on a bifunctional ion-exchange column with oxalic acid as eluent. , 2001, Journal of chromatography. A.

[100]  W. Buchberger Detection techniques in ion chromatography of inorganic ions , 2001 .

[101]  R. Saari-Nordhaus,et al.  Ion chromatographic separation of transition metals on a polybutadiene maleic acid-coated stationary phase , 1994 .

[102]  M. Betti,et al.  Determination of trace elements by ion chromatography , 1991 .

[103]  A. Bond,et al.  Separation and simultaneous determination of aluminum, iron, and manganese in natural water samples by using high-performance liquid chromatography with spectrophotometric and electrochemical detection , 1991 .

[104]  B. Rudenko,et al.  Separation of transition and heavy metals on an amidoxime completing sorbent , 1994 .

[105]  M. Arruda,et al.  Trends in Preconcentration Procedures for Metal Determination Using Atomic Spectrometry Techniques , 2003 .

[106]  J. Broekaert,et al.  Determination of arsenic and selenium species in groundwater and soil extracts by ion chromatography coupled to inductively coupled plasma mass spectrometry , 2001 .

[107]  S. Comber Determination of dissolved copper, nickel and cadmium in natural waters by high-performance liquid chromatography , 1993 .

[108]  T. Clarkson,et al.  Toxic effects of metals , 2001 .

[109]  E. Mentasti,et al.  Simultaneous ion chromatographic determination of selenium and metal ions in waters at trace level , 1990 .

[110]  E. Naujalis,et al.  On-line preconcentration and determination of chromium(VI) in waters by high-performance liquid chromatography using precolumn complexation with 1,5-diphenylcarbazide. , 1998, Journal of chromatography. A.

[111]  M. Trojanowicz,et al.  Determination of triorganotin compounds by ion chromatography and capillary electrophoresis with preconcentration using solid-phase extraction , 1995 .

[112]  A. Timerbaev,et al.  Complexation ion chromatography —an overview of developments and trends in trace metal analysis , 1993 .

[113]  D. Gjerde,et al.  Environmental applications of ion chromatography , 1990 .

[114]  M. Montes-Bayón,et al.  Liquid chromatography-inductively coupled plasma mass spectrometry. , 1999, Journal of chromatography. A.

[115]  P. Haddad,et al.  Dithizone derivatives as sensitive water soluble chromogenic reagents for the ion chromatographic determination of inorganic and organo-mercury in aqueous matrices. , 2003, The Analyst.

[116]  F. Hernández,et al.  Simultaneous determination of arsenic species and chromium(VI) by high-performance liquid chromatography-inductively coupled plasma-mass spectrometry. , 2001, Journal of chromatography. A.

[117]  B. Paull,et al.  Determination of trace cadmium in environmental water samples using ion-interaction reversed-phase liquid chromatography with fluorescence detection. , 2000, Journal of chromatography. A.

[118]  S. Ratering,et al.  Simultaneous Determination of Iron ( III ) , Iron ( II ) , and Manganese ( II ) in Environmental Samples by Ion Chromatography , 1998 .

[119]  Rebecca L. Johnson,et al.  Quantitative trace-level speciation of arsenite and arsenate in drinking water by ion chromatography. , 2002, The Analyst.

[120]  P. Nesterenko,et al.  High-performance chelation ion chromatography a new dimension in the separation and determination of trace metals , 1997 .

[121]  Y. Fung,et al.  Ion chromatographic determination of traces of some oxoanions with direct spectrophotometric detection , 1995 .

[122]  W. P. Miller,et al.  Soluble arsenic and selenium species in fly ash/organic waste-amended soils using ion chromatography-inductively coupled plasma mass spectrometry , 1999 .

[123]  J. Tyson,et al.  Towards Speciation of Arsenic in a Standard Reference River Sediment by High-performance Ion Chromatography Coupled with Plasma Source Mass Spectrometry , 1997 .

[124]  J. Riviello,et al.  Use of ion chromatography for the determination of transition metals in the control of sewage-treatment-plant and related waters , 1997 .

[125]  F. Deutsch,et al.  Analytical characterization of manganese in rainwater and snow samples , 1997 .

[126]  R. Sharma,et al.  Chelating Resins and Their Applications in the Analysis of Trace Metal Ions , 1999 .

[127]  P. Nesterenko,et al.  Dipicolinic acid as eluent for the high-performance liquid chromatographic determination of transition metals using iminodiacetic acid-bonded silica , 1994 .

[128]  N. Cardellicchio,et al.  Direct determination of seleno-amino acids in biological tissues by anion-exchange separation and electrochemical detection. , 1995, Journal of chromatography. A.

[129]  K. Robards,et al.  Metal determination and metal speciation by liquid chromatography. A review , 1991 .

[130]  J. Caruso,et al.  Liquid chromatography-inductively coupled plasma mass spectrometry. , 1999, Journal of chromatography. A.

[131]  G. Stingeder,et al.  CE-ICP-SFMS and HPIC-ICP-SFMS for arsenic speciation in soil solution and soil water extractsPresented at the 2002 Winter Conference on Plasma Spectrochemistry, Scottsdale, AZ, USA, January 6???12, 2002. , 2002 .

[132]  A. Seubert On-line coupling of ion chromatography with ICP–AES and ICP–MS , 2001 .

[133]  Walter C. Shortle,et al.  Applications of ion chromatography to study pollution effects on forest trees , 1990 .

[134]  M. Macka,et al.  Developments in sample preparation and separation techniques for the determination of inorganic ions by ion chromatography and capillary electrophoresis. , 1999, Journal of chromatography. A.

[135]  Nina Ulrich,et al.  Speciation of antimony(III), antimony(V) and trimethylstiboxide by ion chromatography with inductively coupled plasma atomic emission spectrometric and mass spectrometric detection , 1998 .

[136]  E. Sandell,et al.  Photometric Determination of Traces of Metals , 1978 .

[137]  M. C. Bruzzoniti,et al.  Sulphonated azoligand for metal ion determination in ion interaction chromatography , 1999 .

[138]  M. Foltin,et al.  Speciation of mercury by ion chromatography with post-column derivatization , 1996 .

[139]  H. Hara,et al.  Speciation of aluminum in rainwater using a fluoride ion-selective electrode and ion-exchange chromatography with fluorometric detection of the aluminum-lumogallion complex. , 2001, Analytical chemistry.

[140]  P. Haddad,et al.  Chelation ion chromatography of trace metal ions using metallochromic ligands , 1999 .

[141]  B. Rudenko,et al.  Application of multi-dimensional liquid chromatography to the separation of some transition and heavy metals , 1994 .

[142]  B. Paull,et al.  Sensitive and selective ion chromatographic method for the determination of trace beryllium in water samples. , 2001, Journal of chromatography. A.

[143]  H. Tao,et al.  Ion-exclusion chromatography combined with ICP-MS and hydride generation-ICP-MS for the determination of arsenic species in biological matrices , 2000 .

[144]  Paul R. Haddad,et al.  Ion chromatography: principles and applications: (Journal of Chromatography Library, Vol. 46), Elsevier, Amsterdam, 1990 (ISBN 0-444-88232-4). xxi + 776 pp. Price Dfl. 335.00/US $ 171.75 , 1991 .

[145]  P. Haddad,et al.  Ion Chromatography , 2004, Analytical and bioanalytical chemistry.

[146]  J. Boudot,et al.  Validation of an operational procedure for aluminium speciation in soil solutions and surface waters , 1994 .

[147]  B. Paull,et al.  Ionic strength, pH and temperature effects upon selectivity for transition and heavy metal ions when using chelation ion chromatography with an iminodiacetic acid bonded silica gel column and simple inorganic eluents. , 2002, Journal of chromatography. A.

[148]  E. Gautier,et al.  Determination of inorganic and organic anionic arsenic species in water by ion chromatography coupled to hydride generation-inductively coupled plasma atomic emission spectrometry. , 2000, Journal of chromatography. A.

[149]  S. Motellier,et al.  Simultaneous analysis of some transition metals at ultra-trace level by ion-exchange chromatography with on-line preconcentration , 1996 .

[150]  J. Rohrer,et al.  Determination of hexavalent chromium at the level of the California Public Health Goal by ion chromatography. , 2002, Journal of chromatography. A.

[151]  J. Riviello,et al.  Ion chromatography of heavy and transition metals by on- and post-column derivatizations , 2000 .

[152]  W. C. Bauman,et al.  Novel ion exchange chromatographic method using conductimetric detection , 1975 .

[153]  R. Slingsby,et al.  Sample treatment techniques and methodologies for ion chromatography , 2001 .

[154]  W. Buchberger,et al.  Advances in detection techniques for ion chromatography , 1997 .

[155]  J. Ariza,et al.  Stability of chemical species in environmental matrices , 2000 .

[156]  Jürgen Kuballa,et al.  Simultaneous separation of 17 inorganic and organic arsenic compounds in marine biota by means of high-performance liquid chromatography/inductively coupled plasma mass spectrometry. , 2002, Rapid communications in mass spectrometry : RCM.

[157]  J. J. Harwood,et al.  Analysis of organic and inorganic selenium anions by ion chromatography-inductively coupled plasma atomic emission spectroscopy. , 1997, Journal of chromatography. A.

[158]  L. Mathiasson,et al.  Determination of trace metal ions by ion-pair chromatography after enrichment using supported liquid membrane , 1998 .

[159]  C. C. West,et al.  Analysis of Ferric and Ferrous Ions in Soil Extracts by Ion Chromatography , 1998 .

[160]  J. Ščančar,et al.  Determination of hexavalent chromium in lime-treated sewage sludge by anion-exchange fast protein liquid chromatography with electrothermal atomic absorption spectrometry detection. , 2000 .

[161]  N. M. Tahir,et al.  On-line preconcentration and determination of trace metals using a flow injection system coupled to ion chromatography. , 2002, Talanta.

[162]  E. Forgács,et al.  LIQUID CHROMATOGRAPHY OF ORGANOMETALLIC COMPOUNDS , 2002 .

[163]  S. Valsecchi,et al.  Ion-chromatographic screening method for monitoring arsenate and other anionic pollutants in ground waters of Northern Italy. , 2001, Journal of chromatography. A.

[164]  J. Riviello,et al.  SIMULTANEOUS DETERMINATION OF HEAVY AND TRANSITION METALS IN BIOLOGICAL SAMPLES BY CHELATION ION CHROMATOGRAPHY , 2000 .

[165]  J. Riviello,et al.  High-performance ion chromatographic separation of uranium and thorium in natural waters and geological materials , 1992 .

[166]  B. Do,et al.  Application of central composite designs for optimisation of the chromatographic separation of monomethylarsonate and dimethylarsinate and of selenomethionine and selenite by ion-pair chromatography coupled with plasma mass spectrometric detection. , 2001, The Analyst.

[167]  M. Veber,et al.  Effect of organic solvents in the on-line thermal lens spectrometric detection of chromium(III) and chromium(VI) after ion chromatographic separation. , 2001, Journal of chromatography. A.

[168]  B. Rudenko,et al.  Application of a dynamically coated sorbent and conductimetric and UV detectors to the determination of alkaline earth and transition metal cations , 1994 .

[169]  R. Dahl,et al.  The determination of cadmium and six other heavy metals in nitrate/phosphate fertilizer solution by ion chromatography , 1999 .

[170]  M. Magnuson,et al.  Speciation of arsenic compounds by ion chromatography with inductively coupled plasma mass spectrometry detection utilizing hydride generation with a membrane separator , 1996 .

[171]  P. Jackson,et al.  Advances in the determination of inorganic ions in potable waters by ion chromatography. , 2002, Journal of environmental monitoring : JEM.

[172]  D. Sedlak,et al.  Determination of metal complexes of ethylenediaminetetraacetate in the presence of organic matter by high-performance liquid chromatography. , 2001, Journal of chromatography. A.

[173]  M. Ochsenkühn-Petropoulou,et al.  Separation of organotin compounds by ion-exchange chromatography and their determination by inverse voltammetry , 2001, Fresenius' journal of analytical chemistry.

[174]  J. Riviello,et al.  Determination of cadmium and lead at μg/1 levels in aqueous matrices by chelation ion chromatography , 1993 .

[175]  J. Dorsey,et al.  Speciation of inorganic and organotin compounds in biological samples by liquid chromatography with inductively coupled plasma mass spectrometric detection. , 1993, Journal of chromatography. A.

[176]  P. Nesterenko,et al.  Determination of uranium in environmental matrices by chelation ion chromatography using a high performance substrate dynamically modified with 2,6-pyridinedicarboxylic acid , 2000 .

[177]  G. Vance,et al.  Analysis and speciation of selenium ions in mine environments , 1998 .

[178]  Y. Inoue,et al.  Simultaneous determination of chromium(III) and chromium(VI) by ion chromatography with inductively coupled plasma mass spectrometry , 1995 .