Allergic contact sensitization in an adult Danish population: two cross-sectional surveys eight years apart (the Copenhagen Allergy Study).

In 1990 and 1998 15-41-year-old people were patch-tested in 2 cross-sectional studies of random samples of the population in the western part of Copenhagen County, Denmark. In 1990, 290 subjects and in 1998, 469 subjects were patch-tested. The participation rates were 69% and 51%, respectively. Contact sensitivity to one or more haptens was found in 15.9% and 18.6% in 1990 and 1998, respectively. Nickel sensitivity is still the most common contact sensitivity. The risk of contact sensitivity to the cosmetic-related haptens included in the series (formaldehyde was not included) increased significantly from 2.4% in 1990 to 5.8% in 1998 (odds ratio 2.44, 95% confidence interval 1.04-5.73). The prevalence of contact sensitivity to cosmetic-related allergens has been doubled between 1990 and 1998.

[1]  T. Menné,et al.  Allergic contact sensitization in an unselected Danish population. The Glostrup Allergy Study, Denmark. , 1992, Acta dermato-venereologica.

[2]  J. Johansen,et al.  Patch testing with markers of fragrance contact allergy. Do clinical tests correspond to patients' self-reported problems? , 1997, Acta dermato-venereologica.

[3]  J. Hansen,et al.  Chemical, pharmaceutical and clinical standardization of the TRUE Test™ caine mix , 1989, Contact Dermatitis.

[4]  S. Rastogi,et al.  Exposure to selected fragrance materials , 1996, Contact dermatitis.

[5]  J. Ring,et al.  European multicenter study of the TRUE Test™ , 1988, Contact dermatitis.

[6]  P. Frosch,et al.  Deodorants on the European market: quantitative chemical analysis of 21 fragrances , 1998, Contact dermatitis.

[7]  T. Menné,et al.  Quantitative aspects of isoeugenol contact allergy assessed by use and patch tests , 1996, Contact dermatitis.

[8]  S. Fregert,et al.  Terminology of contact dermatitis. , 1970, Acta dermato-venereologica.

[9]  S. Rastogi,et al.  Contact allergy to popular perfumes; assessed by patch test, use test and chemical analysis , 1996, The British journal of dermatology.

[10]  P. Frosch,et al.  European multicenter study of TRUE Test™, Panel 2 , 1990, Contact dermatitis.

[11]  S. Rastogi,et al.  Threshold responses in cinnamic‐aldehyde‐sensitive subjects: results and methodological aspects , 1996, Contact dermatitis.

[12]  J. Johansen,et al.  Rash related to use of scented products. A questionnaire study in the Danish population. Is the problem increasing? , 2000, Contact dermatitis.

[13]  J. Johansen,et al.  The fragrance mix and its constituents: a 14‐year material , 1995, Contact dermatitis.