Background: Body-powered prostheses require cable operation forces between 33 and 131 N. The accepted upper limit for fatigue-free long-duration operation is 20% of a users’ maximum cable operation force. However, no information is available on users’ maximum force. Objectives: To quantify users’ maximum cable operation force and to relate this to the fatigue-free force range for the use of body-powered prostheses. Study design: Experimental trial. Methods: In total, 23 subjects with trans-radial deficiencies used a bypass prosthesis to exert maximum cable force three times during 3 s and reported discomfort or pain on a body map. Additionally, subjects’ anthropometric measures were taken to relate to maximum force. Results: Subjects generated forces ranging from 87 to 538 N. Of the 23 subjects, 12 generated insufficient maximum cable force to operate 8 of the 10 body-powered prostheses fatigue free. Discomfort or pain did not correlate with the magnitude of maximum force achieved by the subjects. Nine subjects indicated discomfort or pain. No relationships between anthropometry and maximal forces were found except for maximum cable forces and the affected upper-arm circumference for females. Conclusion: For a majority of subjects, the maximal cable force was lower than acceptable for fatigue-free prosthesis use. Discomfort or pain occurred in ~40% of the subjects, suggesting a suboptimal force transmission mechanism. Clinical relevance The physical strength of users determines whether a body-powered prosthesis is suitable for comfortable, fatigue-free long-duration use on a daily basis. High cable operation forces can provoke discomfort and pain for some users, mainly in the armpit. Prediction of the users’ strength by anthropometric measures might assist the choice of a suitable prosthesis.
[1]
E. Biddiss,et al.
Upper-Limb Prosthetics: Critical Factors in Device Abandonment
,
2007,
American journal of physical medicine & rehabilitation.
[2]
Elaine Biddiss,et al.
Consumer design priorities for upper limb prosthetics
,
2007,
Disability and rehabilitation. Assistive technology.
[3]
Gerwin Smit,et al.
Efficiency of voluntary opening hand and hook prosthetic devices: 24 years of development?
,
2012,
Journal of rehabilitation research and development.
[4]
H Monod,et al.
Contractility of muscle during prolonged static and repetitive dynamic activity.
,
1985,
Ergonomics.
[5]
David A Abbink,et al.
Perception and control of low cable operation forces in voluntary closing body-powered upper-limb prostheses
,
2019,
PloS one.
[6]
E. Biddiss,et al.
Upper limb prosthesis use and abandonment: A survey of the last 25 years
,
2007,
Prosthetics and orthotics international.
[7]
G. Smit,et al.
Efficiency of Voluntary Closing Hand and Hook Prostheses
,
2010,
Prosthetics and orthotics international.
[8]
G. Kejlaa,et al.
Consumer concerns and the functional value of prostheses to upper limb amputees
,
1993,
Prosthetics and orthotics international.