Experimental Demonstration of Signal-to-Noise-Ratio Improvement of Fourier-Domain Optical Coherence Tomography

A recent advance in optical coherence tomography (OCT), termed swept-source OCT, is generalized into a new technique, Fourier-domain OCT. It represents a realization of a full-field OCT system in place of the conventional serial image acquisition in transverse directions typically implemented in "flying-spot" mode. To realize the full-field image acquisition, a Fourier holography system illuminated with a swept-source is employed instead of a Michelson interferometer commonly used in OCT. Fourier-domain OCT offers a new leap in signal-to-noise ratio improvement, as compared to flying-spot OCT systems. This paper presents experimental evidence that the signal-to-noise ratio of this new technique is indeed improved.

[1]  A. Zvyagin,et al.  Fourier-domain optical coherence tomography: optimization of signal-to-noise ratio in full space , 2004 .

[2]  Teresa C. Chen,et al.  In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography. , 2004, Optics letters.

[3]  S. Yun,et al.  High-speed optical frequency-domain imaging. , 2003, Optics express.

[4]  B. Bouma,et al.  Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. , 2003, Optics letters.

[5]  M. Wojtkowski,et al.  Real-time in vivo imaging by high-speed spectral optical coherence tomography. , 2003, Optics letters.

[6]  Changhuei Yang,et al.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography. , 2003, Optics express.

[7]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[8]  A. Fercher,et al.  Optical coherence tomography - principles and applications , 2003 .

[9]  David Huang,et al.  Handbook of optical coherence tomography. , 2003, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[10]  James G. Fujimoto,et al.  Optical coherence tomography: high-resolution imaging in nontransparent tissue , 1999 .

[11]  Joseph M. Schmitt,et al.  Optical coherence tomography (OCT): a review , 1999 .

[12]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[13]  G. Ha Usler,et al.  "Coherence radar" and "spectral radar"-new tools for dermatological diagnosis. , 1998, Journal of biomedical optics.

[14]  A. Fercher,et al.  Measurement of intraocular distances by backscattering spectral interferometry , 1995 .

[15]  E. Wolf Three-dimensional structure determination of semi-transparent objects from holographic data , 1969 .