Use of a Blood Substitute to Determine Instantaneous Murine Right Ventricular Thickening With Optical Coherence Tomography

Background—A satisfactory imaging technique to determine regional wall thickening of the murine myocardium is not available. Although cardiovascular imaging with light offers a novel solution, application is problematic because scattering by erythrocytes causes significant optical attenuation. Methods and Results—Optical coherence tomography (OCT) is a technique for detailed resolution imaging of highly scattering biological tissues. To reduce the high level of blood scattering, a method was devised whereby murine blood was replaced with a hemoglobin-based blood substitute. The scattering and absorption properties of in vitro preparations of whole blood and dilutions of blood with a blood substitute were determined with a spectrophotometer and an inverse-adding doubling algorithm. OCT imaging of the same dilutions demonstrated a significant reduction in scattering at a hematocrit <5%. A fiber-optic OCT imaging system was used to image the murine right midventricular free wall before and after isovolumic replacement with blood substitute. Strong light attenuation prevented full thickness imaging before replacement, whereas visualization of the full ventricular thickness was possible after replacement. Baseline and imaging hematocrits were 52.4±3.8% and 3.7±1.2%, respectively. End-systolic and end-diastolic thickness values were 0.458±0.051 mm and 0.352±0.047 mm. Percent thickening fraction was 30.8± 7.5%. Conclusion—Optical imaging of the intact beating murine right ventricle was substantially improved by isovolumic blood replacement with a hemoglobin-based blood substitute. Although the current study has been directed toward imaging the murine heart, a blood substitute may be applied to various optical diagnostic and therapeutic techniques under investigation in cardiovascular medicine.

[1]  W. Cheong,et al.  Photoangioplasty: An emerging clinical cardiovascular role for photodynamic therapy. , 2000, Circulation.

[2]  M Fitzmaurice,et al.  Histopathology of human coronary atherosclerosis by quantifying its chemical composition with Raman spectroscopy. , 1998, Circulation.

[3]  B. Hooper Optical-thermal response of laser-irradiated tissue , 1996 .

[4]  B E Bouma,et al.  High resolution in vivo intra-arterial imaging with optical coherence tomography , 1999, Heart.

[5]  M. Ducros,et al.  Primate retina imaging with polarization-sensitive optical coherence tomography. , 2001, Journal of the Optical Society of America. A, Optics, image science, and vision.

[6]  M. V. van Gemert,et al.  Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography. , 1997, Optics letters.

[7]  M S Feld,et al.  Determination of human coronary artery composition by Raman spectroscopy. , 1997, Circulation.

[8]  G. Vlahakes,et al.  Hemodynamic effects and oxygen transport properties of a new blood substitute in a model of massive blood replacement. , 1990, The Journal of thoracic and cardiovascular surgery.

[9]  A. Haase,et al.  Perfusion‐corrected mapping of cardiac regional blood volume in rats in vivo , 1999, Magnetic resonance in medicine.

[10]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[11]  John M. Neet,et al.  Navigating a guide wire through total occlusions: clinical experience , 2000, Photonics West - Biomedical Optics.

[12]  V. Twersky Absorption and multiple scattering by biological suspensions. , 1970, Journal of the Optical Society of America.

[13]  C. Lok Blood product from cattle wins approval for use in humans , 2001, Nature.

[14]  J M Schmitt,et al.  Subsurface imaging of living skin with optical coherence microscopy. , 1995, Dermatology.

[15]  P. Hunziker,et al.  Determination of right ventricular structure and function in normoxic and hypoxic mice: a transesophageal echocardiographic study. , 1998, Circulation.

[16]  Francis A. Duck,et al.  Optical Properties of Tissue including Ultraviolet and Infrared Radiation , 1990 .

[17]  J. Fujimoto,et al.  Assessment of coronary plaque with optical coherence tomography and high-frequency ultrasound. , 2000, The American journal of cardiology.

[18]  J. Nelson,et al.  Group refractive index measurement of dry and hydrated type I collagen films using optical low-coherence reflectometry. , 1996, Journal of biomedical optics.

[19]  A. Welch,et al.  Determining the optical properties of turbid mediaby using the adding-doubling method. , 1993, Applied optics.

[20]  Ashleyj . Welch,et al.  Optical-Thermal Response of Laser-Irradiated Tissue , 1995 .

[21]  Francis A. Duck,et al.  Physical properties of tissue : a comprehensive reference book , 1990 .

[22]  J. Fujimoto,et al.  Determination of the refractive index of highly scattering human tissue by optical coherence tomography. , 1995, Optics letters.

[23]  G. D. Meier,et al.  Contractile function in canine right ventricle. , 1980, The American journal of physiology.

[24]  G. Noon,et al.  An accurate, nontraumatic ultrasonic method to monitor myocardial wall thickening in patients undergoing cardiac surgery. , 1990, Journal of the American College of Cardiology.

[25]  A. Roggan,et al.  Optical Properties of Circulating Human Blood in the Wavelength Range 400-2500 nm. , 1999, Journal of biomedical optics.

[26]  J. Fujimoto,et al.  Noninvasive assessment of the developing Xenopus cardiovascular system using optical coherence tomography. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[27]  J. Fujimoto,et al.  Index Matching to Improve Optical Coherence Tomography Imaging Through Blood , 2001, Circulation.

[28]  Babs R. Soller,et al.  Application of IR and NIR fiber optic imaging in thermographic and spectroscopic diagnosis of atherosclerotic vulnerable plaques: preliminary experience , 2000, SPIE Optics + Photonics.

[29]  Brian C. Wilson,et al.  Measurement of Tissue Optical Properties: Methods and Theories , 1995 .

[30]  A. P. Shepherd,et al.  Role of Light Scatterng in Whole Blood Oximetry , 1986, IEEE Transactions on Biomedical Engineering.

[31]  A Rollins,et al.  In vivo video rate optical coherence tomography. , 1998, Optics express.

[32]  J. Fujimoto,et al.  High-speed phase- and group-delay scanning with a grating-based phase control delay line. , 1997, Optics letters.

[33]  D. Spahn,et al.  Physiological properties of blood substitutes. , 2001, News in physiological sciences : an international journal of physiology produced jointly by the International Union of Physiological Sciences and the American Physiological Society.

[34]  J. Fujimoto,et al.  Optical coherence tomography of the human retina. , 1995, Archives of ophthalmology.

[35]  J O ELAM,et al.  Influence of oxygen saturation, erythrocyte concentration and optical depth upon the red and near-infrared light transmittance of whole blood. , 1951, The American journal of physiology.

[36]  B E Bouma,et al.  Imaging of coronary artery microstructure (in vitro) with optical coherence tomography. , 1996, The American journal of cardiology.