Performance validation of an improved Xenon‐arc lamp‐based CCD camera system for multispectral imaging in proteomics

Advances in gel‐based nonradioactive protein expression and PTM detection using fluorophores has served as the impetus for developing analytical instrumentation with improved imaging capabilities. We describe a CCD camera‐based imaging instrument, equipped with both a high‐pressure Xenon arc lamp and a UV transilluminator, which provides broad‐band wavelength coverage (380–700 nm and UV). With six‐position filter wheels, both excitation and emission wavelengths may be selected, providing optimal measurement and quantitation of virtually any dye and allowing excellent spectral resolution among different fluorophores. While spatial resolution of conventional fixed CCD camera imaging systems is typically inferior to laser scanners, this problem is circumvented with the new instrument by mechanically scanning the CCD camera over the sample and collecting multiple images that are subsequently automatically reconstructed into a complete high‐resolution image. By acquiring images in succession, as many as four different fluorophores may be evaluated from a gel. The imaging platform is suitable for analysis of the wide range of dyes and tags commonly encountered in proteomics investigations. The instrument is unique in its capabilities of scanning large areas at high resolution and providing accurate selectable illumination over the UV/visible spectral range, thus maximizing the efficiency of dye multiplexing protocols.

[1]  A E Dixon,et al.  Imaging electrophoretic gels with a scanning beam laser macroscope , 1995, Electrophoresis.

[2]  Mary F. Lopez,et al.  High‐throughput profiling of the mitochondrial proteome using affinity fractionation and automation , 2000, Electrophoresis.

[3]  Wayne F. Patton,et al.  Mapping glycosylation changes related to cancer using the Multiplexed Proteomics technology: a protein differential display approach. , 2003, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[4]  Wayne F. Patton,et al.  Optimized conditions for diluting and reusing a fluorescent protein gel stain , 2004, Electrophoresis.

[5]  M. Ünlü,et al.  Difference gel electrophoresis. A single gel method for detecting changes in protein extracts , 1997, Electrophoresis.

[6]  Wayne F. Patton,et al.  An improved formulation of SYPRO Ruby protein gel stain: Comparison with the original formulation and with a ruthenium II tris (bathophenanthroline disulfonate) formulation , 2002, Proteomics.

[7]  M D Miller,et al.  Digital imaging considerations for gel electrophoresis analysis systems , 2001, Electrophoresis.

[8]  C. Pace,et al.  How to measure and predict the molar absorption coefficient of a protein , 1995, Protein science : a publication of the Protein Society.

[9]  P. Cutler,et al.  A statistical comparison of silver and SYPRO Ruby staining for proteomic analysis , 2004, Electrophoresis.

[10]  Wayne F. Patton,et al.  Background‐free, high sensitivity staining of proteins in one‐ and two‐dimensional sodium dodecyl sulfate‐polyacrylamide gels using a luminescent ruthenium complex , 2000, Electrophoresis.

[11]  A. Burkovski,et al.  Detection of fluorescence dye-labeled proteins in 2-D gels using an Arthur 1442 Multiwavelength Fluoroimager. , 2001, BioTechniques.

[12]  Wayne F. Patton,et al.  Global quantitative phosphoprotein analysis using Multiplexed Proteomics technology , 2003, Proteomics.

[13]  B. Lewis,et al.  Detection and quantification of biotinylated proteins using the Storm 840 Optical Scanner. , 2003, Journal of Nutritional Biochemistry.

[14]  Wayne F. Patton,et al.  Detection technologies in proteome analysis. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[15]  P. Jackson,et al.  Two-dimensional polyacrylamide gel electrophoresis of proteins labeled with the fluorophore monobromobimane prior to first-dimensional isoelectric focusing: imaging of the fluorescent protein spot patterns using a cooled charge-coupled device. , 1993, Analytical biochemistry.

[16]  P. McNamara,et al.  Fluorescent imaging and analysis with Typhoon 8600 , 2001, Electrophoresis.

[17]  Wayne F. Patton,et al.  Combining microscale solution‐phase isoelectric focusing with Multiplexed Proteomics® dye staining to analyze protein post‐translational modifications , 2004, Electrophoresis.

[18]  C. Mackay,et al.  Rapid imaging, using a cooled charge‐coupled‐device, of fluorescent two‐dimensional polyacrylamide gels produced by labelling proteins in the first‐dimensional isoelectric focusing gel with the fluorophore 2‐methoxy‐2,4‐diphenyl‐3(2H)furanone , 1988, Electrophoresis.

[19]  R. Leimgruber,et al.  Practical aspects of fluorescent staining for proteomic applications , 2001, Electrophoresis.

[20]  F. J. Alba,et al.  Rapid fluorescent monitoring of total protein patterns on sodium dodecyl sulfate‐polyacrylamide gels and Western blots before immunodetection and sequencing , 1998, Electrophoresis.

[21]  P. Jackson,et al.  A multiple high-resolution mini two-dimensional polyacrylamide gel electrophoresis system: imaging two-dimensional gels using a cooled charge-coupled device after staining with silver or labeling with fluorophore. , 1991, Analytical biochemistry.

[22]  Wayne F. Patton Biologist's perspective on analytical imaging systems as applied to protein gel electrophoresis , 1995 .

[23]  Matthew Davison,et al.  Validation and development of fluorescence two‐dimensional differential gel electrophoresis proteomics technology , 2001, Proteomics.

[24]  G. Ostermeier,et al.  Multitasking with molecular dynamics Typhoon: quantifying nucleic acids and autoradiographs , 2003, Biotechnology Letters.

[25]  Stephen O. David,et al.  A novel experimental design for comparative two‐dimensional gel analysis: Two‐dimensional difference gel electrophoresis incorporating a pooled internal standard , 2003, Proteomics.

[26]  H. Vogel,et al.  Phosphorus-31 nuclear magnetic resonance studies of the two phosphoserine residues of hen egg white ovalbumin. , 1982, Biochemistry.

[27]  R. Haugland,et al.  Applications of SYPRO orange and SYPRO red protein gel stains. , 1996, Analytical biochemistry.

[28]  L. Jones,et al.  SYPRO orange and SYPRO red protein gel stains: one-step fluorescent staining of denaturing gels for detection of nanogram levels of protein. , 1996, Analytical biochemistry.

[29]  Wayne F. Patton,et al.  A thousand points of light: The application of fluorescence detection technologies to two‐dimensional gel electrophoresis and proteomics , 2000, Electrophoresis.

[30]  Kenji Miura,et al.  Imaging and detection technologies for image analysis in electrophoresis , 2001, Electrophoresis.

[31]  Wayne F. Patton Making blind robots see: the synergy between fluorescent dyes and imaging devices in automated proteomics. , 2000, BioTechniques.

[32]  F. J. Alba,et al.  Detection of five nanograms of protein by two-minute nile red staining of unfixed SDS gels. , 1996, BioTechniques.

[33]  P. V. von Hippel,et al.  Calculation of protein extinction coefficients from amino acid sequence data. , 1989, Analytical biochemistry.

[34]  Wayne F. Patton,et al.  Simultaneous red/green dual fluorescence detection on electroblots using BODIPY TR‐X succinimidyl ester and ELF 39 phosphate , 2002, Proteomics.

[35]  Wayne F. Patton,et al.  Rainbow's end: the quest for multiplexed fluorescence quantitative analysis in proteomics. , 2002, Current opinion in chemical biology.

[36]  Wayne F. Patton,et al.  Simultaneous trichromatic fluorescence detection of proteins on Western blots using an amine‐reactive dye in combination with alkaline phosphatase‐ and horseradish peroxidase‐antibody conjugates , 2003, Proteomics.

[37]  Microscale fractionation facilitates detection of differentially expressed proteins in Alzheimer's disease brain samples , 2004, Electrophoresis.

[38]  M. Homma,et al.  Practical applications in molecular biology of sensitive fluorescence detection by a laser-excited fluorescence image analyzer. , 1992, BioTechniques.

[39]  P Jackson,et al.  A unique charge‐coupled device/xenon arc lamp based imaging system for the accurate detection and quantitation of multicolour fluorescence , 2001, Electrophoresis.

[40]  P. Jackson,et al.  Polyacrylamide gel electrophoresis of reducing saccharides labeled with the fluorophore 2-aminoacridone: subpicomolar detection using an imaging system based on a cooled charge-coupled device. , 1991, Analytical biochemistry.

[41]  E. Petricoin,et al.  Dilution of protein gel stain results in retention of staining capacity. , 2003, BioTechniques.

[42]  I. Bronstein,et al.  Imaging of chemiluminescent signals with cooled CCD camera systems. , 1994, Journal of bioluminescence and chemiluminescence.

[43]  Wayne F. Patton,et al.  Green/red dual fluorescence detection of total protein and alkaline phosphate‐conjugated probes on blotting membranes , 2001, Electrophoresis.

[44]  P Jackson,et al.  The use of polyacrylamide-gel electrophoresis for the high-resolution separation of reducing saccharides labelled with the fluorophore 8-aminonaphthalene-1,3,6-trisulphonic acid. Detection of picomolar quantities by an imaging system based on a cooled charge-coupled device. , 1990, The Biochemical journal.

[45]  Kenji Miura,et al.  Imaging technologies for the detection of multiple stains in proteomics , 2003, Proteomics.

[46]  J C Sutherland,et al.  Quantitative electronic imaging of gel fluorescence with CCD cameras: applications in molecular biology. , 1991, BioTechniques.