Position-sensitive germanium detectors for gamma-ray imaging and spectroscopy

Gamma-ray imaging with position-sensitive germanium detectors offers the advantages of excellent energy resolution, high detection efficiency, and potentially good spatial resolution. The development of the amorphous-semiconductor electrical contact technology for germanium detectors has simplified the production of these position-sensitive detectors and has made possible the use of unique detection schemes and detector geometries. We have fabricated prototype orthogonal-strip detectors for gamma-ray imaging studies using this contact technology. With these detectors, we demonstrate that a gamma- ray interaction event in the detector can be located in three dimensions. This more accurate determination of the interaction event position should ultimately lead to better image resolution. We have also taken advantage of the bipolar blocking nature of the amorphous-semiconductor contacts in order to investigate the use of field-shaping electrodes. The addition of such electrodes is shown to improve the spectroscopic performance of the detectors by substantially eliminating charge collection to the inter-electrode surfaces. In addition, we demonstrate that this incomplete charge collection process can also be reduced by adjusting the properties of the amorphous-semiconductor layer. In this paper, we summarize the development of these position- sensitive detectors and present the results of our studies with the detectors.

[1]  P. Luke,et al.  Amorphous silicon/crystalline silicon heterojunctions for nuclear radiation detector applications , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[2]  E. Haller,et al.  Amorphous Germanium as an Electron or Hole Blocking Contact on High-Purity Germanium Detectors , 1976, IEEE Transactions on Nuclear Science.

[3]  D. Protic,et al.  Energy and position resolution of germanium microstrip detectors at X-ray energies from 15 to 100 keV , 1997 .

[4]  A. Hamacher,et al.  Performance of position-sensitive germanium detectors in nuclear reaction experiments , 1990 .

[5]  S. M. Sze Physics of semiconductor devices /2nd edition/ , 1981 .

[6]  D. Miller,et al.  A Multi-Detector Germanium Gamma Ray Camera , 1979, IEEE Transactions on Nuclear Science.

[7]  R. Dinger,et al.  Charge Collection in Surface Channels on High-Purity Ge Detectors , 1976, IEEE Transactions on Nuclear Science.

[8]  W. Shockley Currents to Conductors Induced by a Moving Point Charge , 1938 .

[9]  J. Ewins,et al.  Two-Detector, 512-Element High Purity Germanium Camera Prototype , 1978, IEEE Transactions on Nuclear Science.

[10]  M. Amman,et al.  Three-dimensional position sensing and field shaping in orthogonal-strip germanium gamma-ray detectors. , 2000 .

[11]  N. Madden,et al.  Amorphous Ge bipolar blocking contacts on Ge detectors , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[12]  E. E. Haller,et al.  Protective Surface Coatings on Semiconductor Nuclear Radiation Detectors , 1980, IEEE Transactions on Nuclear Science.

[13]  M. Drouillon,et al.  A. M. A. , 2019, California state journal of medicine.

[14]  Theodore I. Kamins,et al.  Device Electronics for Integrated Circuits , 1977 .

[15]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[16]  H. B. Barber,et al.  Charge transport in arrays of semiconductor gamma-ray detectors. , 1995, Physical review letters.

[17]  James D. Kurfess,et al.  Charge spreading and position sensitivity in a segmented planar germanium detector , 1999 .

[18]  W. Collis,et al.  A Practical Gamma-Ray Camera System Using High-Purity Germanium , 1974 .

[19]  C. Canali,et al.  Gamma−ray spectroscopy with single−carrier collection in high−resistivity semiconductors , 1975 .

[20]  D. Protic,et al.  Position-Sensitive Germanium Detectors , 1985, IEEE Transactions on Nuclear Science.

[21]  William K. Warburton,et al.  Position resolution in a Ge-strip detector , 1999, Optics & Photonics.

[22]  R. Street,et al.  Hydrogenated amorphous silicon: Index , 1991 .

[23]  D. Gutknecht,et al.  Photomask technique for fabricating high purity germanium strip detectors , 1990 .

[24]  S. Ramo Currents Induced by Electron Motion , 1939, Proceedings of the IRE.

[25]  P. Luke Gold-Mask Technique for Fabricating Segmented-Electrode Germanium Detectors , 1984, IEEE Transactions on Nuclear Science.

[26]  R. Pehl,et al.  A 140-element Ge Detector Fabricated With Amorphous Ge Blocking Contacts , 1993, 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference.

[27]  S. M. Sze,et al.  Physics of semiconductor devices , 1969 .

[28]  P. Luke Electrode configuration and energy resolution in gamma-ray detectors , 1996 .