Electromagnetic Immunity Performance of Intelligent Electronic Equipment in Smart Substation’s Electromagnetic Environment

With the gradual increasing of the transmission voltage level, the situation of interference on secondary side equipment in smart substations is becoming more serious. The authors tested the interference waveforms caused by the circuit breaker’s operation at the smart substation, which showed the severity of the electromagnetic (EM) environment. This paper takes the electronic current transformer acquisition card as an example. The influence of EM interference sources on the reliability of the acquisition card is analyzed. Then, standardized electromagnetic compatibility (EMC) immunity tests of the international electrotechnical commission (IEC) for different interferences are implemented. Typical output characteristics of acquisition cards for different tests are analyzed. Innovatively, this paper proposes a quantitative evaluation method of output waveform disturbance to evaluate the acquisition card’s performance. This disturbance distortion is of great significance to the EM environment estimation of the acquisition card.

[1]  Lasse Hugo Sivertsen,et al.  A New Approach to Include Complex Grounding System in Lightning Transient Studies and EMI Evaluations , 2019, Energies.

[2]  A. Finney The problem of size (EMC testing) , 1994 .

[3]  Jean-Luc Levant,et al.  Immunity Measurement and Modeling of an ADC Embedded in a Microcontroller Using RFIP Technique , 2015, IEEE Transactions on Electromagnetic Compatibility.

[4]  Xiang Cui,et al.  Transient Electromagnetic Disturbance Induced on the Ports of Intelligent Component of Electronic Instrument Transformer Due to Switching Operations in 500 kV GIS Substations , 2017, IEEE Access.

[5]  He Jinliang,et al.  Discussion on Electromagnetic Compatibility Index for Secondary System of Substation , 2007, 2007 International Symposium on Electromagnetic Compatibility.

[6]  C. Piner,et al.  Radiated emissions from FACTS equipment operational within substations-part III , 2005, IEEE Transactions on Power Delivery.

[7]  S. Okabe,et al.  Grounding System Transient Characteristics of Underground GIS Substations , 2012, IEEE Transactions on Power Delivery.

[8]  Lei Liu,et al.  Simulation of Electromagnetic Transients of the Bus Bar in Substation by the Time-Domain Finite-Element Method , 2009, IEEE Transactions on Electromagnetic Compatibility.

[9]  Grzegorz Lubkowski,et al.  Electromagnetic Immunity of Mobile Devices - Statistical Analysis , 2018, 2018 International Symposium on Electromagnetic Compatibility (EMC EUROPE).

[10]  Er-Ping Li,et al.  Behavioral modeling for electromagnetic immunity analysis for electronic systems , 2010, 2010 Asia-Pacific International Symposium on Electromagnetic Compatibility.

[11]  Christian Marot,et al.  Electromagnetic simulation to predict EMC immunity behavior of an aeronautic board , 2014, 2014 International Symposium on Electromagnetic Compatibility.

[12]  Davor Grgić,et al.  Room Classification Based on EMC Conditions in Nuclear Power Plants , 2020 .

[13]  Arthur Radun,et al.  An alternative low-cost current-sensing scheme for high-current power electronics circuits , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[14]  Tom Dhaene,et al.  Machine Learning Based Error Detection in Transient Susceptibility Tests , 2019, IEEE Transactions on Electromagnetic Compatibility.

[15]  Urban Metod Peterlin,et al.  Electromagnetic compatibility levels in power plants and substations , 2015, 2015 IEEE International Symposium on Electromagnetic Compatibility (EMC).

[16]  S. M. Harvey,et al.  Radio interference and transient field from gas-insulated substations , 1995 .

[17]  Alexandre Boyer,et al.  Characterisation of electromagnetic compatibility drifts of nanoscale integrated circuit after accelerated life tests , 2010 .

[18]  He Jinliang,et al.  Electromagnetic Interference on Secondary Systems of Substation Caused by Short-circuit Fault , 2007, 2007 International Symposium on Electromagnetic Compatibility.

[19]  Y. Trenkler,et al.  Characterization of metals as EMC shields , 1987, IEEE Transactions on Instrumentation and Measurement.

[20]  Hui Dou,et al.  Simulation of electromagnetic interference coupling to a substation secondary cable , 2010, 2010 Asia-Pacific International Symposium on Electromagnetic Compatibility.

[21]  Jin Liu,et al.  Immunity model study on irradiation effect of Electrostatic electromagnetic pulses , 2010, 2010 International Conference On Computer Design and Applications.

[22]  W. H. Siew,et al.  Radiated interference from a high voltage impulse generator , 1996 .

[23]  Jakub Furgał,et al.  Influence of Lightning Current Model on Simulations of Overvoltages in High Voltage Overhead Transmission Systems , 2020, Energies.

[24]  Xiang Cui,et al.  Numerical prediction of EMI on the secondary DC cable in cable tunnel due to a direct lightning strike in substation , 2006, IEEE Transactions on Magnetics.

[25]  H. Heydari,et al.  Impact of Switching-Induced Electromagnetic Interference on Low-Voltage Cables in Substations , 2009, IEEE Transactions on Electromagnetic Compatibility.

[26]  Emrah Tas,et al.  Design, Implementation, and Evaluation of Proficiency Testing in EMC Conducted Immunity , 2017, IEEE Transactions on Electromagnetic Compatibility.

[27]  S. E. Wright,et al.  Transient electromagnetic interference in substations , 1994 .

[28]  Hui Dou,et al.  Simulation of electromagnetic transients in air insulated substation due to switch operation , 2009, 2009 5th Asia-Pacific Conference on Environmental Electromagnetics.