Phase-contrast and fluorescent X-ray imaging for biomedical researches
暂无分享,去创建一个
[1] T Takeda,et al. Phase-contrast X-ray imaging with a large monolithic X-ray interferometer. , 2000, Journal of synchrotron radiation.
[2] S. Wilkins,et al. Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.
[3] M. Takeda,et al. Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry , 1982 .
[4] J. Weigelt,et al. X-ray fluorescent computer tomography with synchrotron radiation , 1998 .
[5] Tetsuya Yuasa,et al. SR biomedical imaging with phase-contrast and fluorescent x-ray CT , 2004, SPIE Optics + Photonics.
[6] Richard J. Fitzgerald,et al. Phase‐Sensitive X‐Ray Imaging , 2000 .
[7] Tetsuya Yuasa,et al. Iodine imaging in thyroid by fluorescent X-ray CT with 0.05 mm spatial resolution , 2001 .
[8] A. Momose,et al. Phase-contrast radiographs of nonstained rat cerebellar specimen. , 1995, Medical physics.
[9] E. Pisano,et al. Human breast cancer specimens: diffraction-enhanced imaging with histologic correlation--improved conspicuity of lesion detail compared with digital radiography. , 2000, Radiology.
[10] Atsushi Momose,et al. Large-area phase-contrast X-ray imaging using a two-crystal X-ray interferometer. , 2002, Journal of synchrotron radiation.
[11] Atsushi Momose,et al. Phase-contrast microtomography using an X-ray interferometer having a 40-μm analyzer , 2003 .
[12] 江橋 節郎,et al. Handbook on synchrotron radiation , 1983 .
[13] Atsushi Momose,et al. Phase–contrast X–ray computed tomography for observing biological soft tissues , 1996, Nature Medicine.
[14] R. Gonsalves,et al. Fluorescent computer tomography: a model for correction of X-ray absorption , 1991 .
[15] Kazuyuki Hyodo,et al. A phase-contrast X-ray imaging system—with a 60×30 mm field of view—based on a skew-symmetric two-crystal X-ray interferometer , 2004 .
[16] Kazuyuki Hyodo,et al. In-Vivo Imaging of Cancer Implanted in Nude Mice by Two-Crystal Interferometer-Based Phase-Contrast X-Ray Computed Tomography , 2004 .
[17] Atsushi Momose,et al. Wide-area phase-contrast X-ray imaging using large X-ray interferometers , 2001 .
[18] T Takeda,et al. Human carcinoma: early experience with phase-contrast X-ray CT with synchrotron radiation--comparative specimen study with optical microscopy. , 2000, Radiology.
[19] T Takeda,et al. Phase-contrast imaging with synchrotron X-rays for detecting cancer lesions. , 1995, Academic radiology.
[20] T Akatsuka,et al. Preliminary experiment of fluorescent X-ray computed tomography to detect dual agents for biological study. , 2001, Journal of synchrotron radiation.
[21] T Akatsuka,et al. New types of X-ray computed tomography (CT) with synchrotron radiation: fluorescent X-ray CT and phase-contrast X-ray CT using interferometer. , 2000, Cellular and molecular biology.
[22] U. Bonse,et al. AN X‐RAY INTERFEROMETER , 1965 .
[23] Kazuyuki Hyodo,et al. Interferometric X-Ray Imaging of Breast Cancer Specimens at 51 keV X-Ray Energy , 2004 .
[24] F Busch,et al. X-ray microtomography (microCT) using phase contrast for the investigation of organic matter. , 1997, Journal of computer assisted tomography.
[25] Atsushi Momose,et al. Demonstration of phase-contrast X-ray computed tomography using an X-ray interferometer , 1995 .
[26] A. Momose,et al. Operation of a Two-Crystal X-ray Interferometer at the Photon Factory. , 1997, Journal of synchrotron radiation.
[27] E Castelli,et al. Mammography with synchrotron radiation: phase-detection techniques. , 2000, Radiology.
[28] Nigel Kirkham,et al. Progress in Pathology , 1995 .
[29] E. Pisano,et al. Diffraction enhanced x-ray imaging. , 1997, Physics in medicine and biology.
[30] Tetsuya Yuasa,et al. Reconstruction method for fluorescent X-ray computed tomography by least-squares method using singular value decomposition , 1997 .