Phase-contrast and fluorescent X-ray imaging for biomedical researches

Abstract Synchrotron X-ray imaging systems with phase-contrast and fluorescent techniques have been developed for biomedical researches. Since phase-contrast X-ray imaging with an X-ray interferometer is a highly sensitive imaging technique to differentiate the inner soft tissue in biological object, detailed morphological structures can be imaged without the use of contrast material. Fluorescent X-ray CT detects specific heavy atomic number elements such as iodine at the order of picogram in a volume of 10 −6  ml, so the functional information with labeling agents can be obtained. Here, I describe recent in vivo and ex vivo experimental results obtained by these imaging techniques.

[1]  T Takeda,et al.  Phase-contrast X-ray imaging with a large monolithic X-ray interferometer. , 2000, Journal of synchrotron radiation.

[2]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.

[3]  M. Takeda,et al.  Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry , 1982 .

[4]  J. Weigelt,et al.  X-ray fluorescent computer tomography with synchrotron radiation , 1998 .

[5]  Tetsuya Yuasa,et al.  SR biomedical imaging with phase-contrast and fluorescent x-ray CT , 2004, SPIE Optics + Photonics.

[6]  Richard J. Fitzgerald,et al.  Phase‐Sensitive X‐Ray Imaging , 2000 .

[7]  Tetsuya Yuasa,et al.  Iodine imaging in thyroid by fluorescent X-ray CT with 0.05 mm spatial resolution , 2001 .

[8]  A. Momose,et al.  Phase-contrast radiographs of nonstained rat cerebellar specimen. , 1995, Medical physics.

[9]  E. Pisano,et al.  Human breast cancer specimens: diffraction-enhanced imaging with histologic correlation--improved conspicuity of lesion detail compared with digital radiography. , 2000, Radiology.

[10]  Atsushi Momose,et al.  Large-area phase-contrast X-ray imaging using a two-crystal X-ray interferometer. , 2002, Journal of synchrotron radiation.

[11]  Atsushi Momose,et al.  Phase-contrast microtomography using an X-ray interferometer having a 40-μm analyzer , 2003 .

[12]  江橋 節郎,et al.  Handbook on synchrotron radiation , 1983 .

[13]  Atsushi Momose,et al.  Phase–contrast X–ray computed tomography for observing biological soft tissues , 1996, Nature Medicine.

[14]  R. Gonsalves,et al.  Fluorescent computer tomography: a model for correction of X-ray absorption , 1991 .

[15]  Kazuyuki Hyodo,et al.  A phase-contrast X-ray imaging system—with a 60×30 mm field of view—based on a skew-symmetric two-crystal X-ray interferometer , 2004 .

[16]  Kazuyuki Hyodo,et al.  In-Vivo Imaging of Cancer Implanted in Nude Mice by Two-Crystal Interferometer-Based Phase-Contrast X-Ray Computed Tomography , 2004 .

[17]  Atsushi Momose,et al.  Wide-area phase-contrast X-ray imaging using large X-ray interferometers , 2001 .

[18]  T Takeda,et al.  Human carcinoma: early experience with phase-contrast X-ray CT with synchrotron radiation--comparative specimen study with optical microscopy. , 2000, Radiology.

[19]  T Takeda,et al.  Phase-contrast imaging with synchrotron X-rays for detecting cancer lesions. , 1995, Academic radiology.

[20]  T Akatsuka,et al.  Preliminary experiment of fluorescent X-ray computed tomography to detect dual agents for biological study. , 2001, Journal of synchrotron radiation.

[21]  T Akatsuka,et al.  New types of X-ray computed tomography (CT) with synchrotron radiation: fluorescent X-ray CT and phase-contrast X-ray CT using interferometer. , 2000, Cellular and molecular biology.

[22]  U. Bonse,et al.  AN X‐RAY INTERFEROMETER , 1965 .

[23]  Kazuyuki Hyodo,et al.  Interferometric X-Ray Imaging of Breast Cancer Specimens at 51 keV X-Ray Energy , 2004 .

[24]  F Busch,et al.  X-ray microtomography (microCT) using phase contrast for the investigation of organic matter. , 1997, Journal of computer assisted tomography.

[25]  Atsushi Momose,et al.  Demonstration of phase-contrast X-ray computed tomography using an X-ray interferometer , 1995 .

[26]  A. Momose,et al.  Operation of a Two-Crystal X-ray Interferometer at the Photon Factory. , 1997, Journal of synchrotron radiation.

[27]  E Castelli,et al.  Mammography with synchrotron radiation: phase-detection techniques. , 2000, Radiology.

[28]  Nigel Kirkham,et al.  Progress in Pathology , 1995 .

[29]  E. Pisano,et al.  Diffraction enhanced x-ray imaging. , 1997, Physics in medicine and biology.

[30]  Tetsuya Yuasa,et al.  Reconstruction method for fluorescent X-ray computed tomography by least-squares method using singular value decomposition , 1997 .