Accelerometer-based step initiation control for gait-assist neuroprostheses.

Electrical activation of paralyzed musculature can generate or augment joint movements required for walking after central nervous system trauma. Proper timing of stimulation relative to residual volitional control is critical to usefully affecting ambulation. This study evaluates three-dimensional accelerometers and customized algorithms to detect the intent to step from voluntary movements to trigger stimulation during walking in individuals with significantly different etiologies, mobility limitations, manual dexterities, and walking aids. Three individuals with poststroke hemiplegia or partial spinal cord injury exhibiting varying gait deficits were implanted with multichannel pulse generators to provide joint motions at the hip, knee, and ankle. An accelerometer integrated into the external control unit was used to detect heel strike or walker movement, and wireless accelerometers were used to detect crutch strike. Algorithms were developed for each sensor location to detect intent to step to progress through individualized stimulation patterns. Testing these algorithms produced detection accuracies of at least 90% on both level ground and uneven terrain. All participants use their accelerometer-triggered implanted gait systems in the community; the validation/system testing was completed in the hospital. The results demonstrated that safe, reliable, and convenient accelerometer-based step initiation can be achieved regardless of specific gait deficits, manual dexterities, and walking aids.

[1]  Maarten J. IJzerman,et al.  A randomized controlled trial of an implantable 2-channel peroneal nerve stimulator on walking speed and activity in poststroke hemiplegia. , 2007, Archives of physical medicine and rehabilitation.

[2]  T. Bajd,et al.  The use of a four-channel electrical stimulator as an ambulatory aid for paraplegic patients. , 1983, Physical therapy.

[3]  R J Triolo,et al.  Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia. , 1997, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[4]  J. R. Schnellenberger,et al.  Sensor-based hip control with hybrid neuroprosthesis for walking in paraplegia. , 2014, Journal of rehabilitation research and development.

[5]  D. Liebetanz,et al.  Towards physiological ankle movements with the ActiGait implantable drop foot stimulator in chronic stroke , 2013, Biomedizinische Technik. Biomedical engineering.

[6]  Kevin M. Foglyano,et al.  A preliminary comparison of myoelectric and cyclic control of an implanted neuroprosthesis to modulate gait speed in incomplete SCI , 2015, The journal of spinal cord medicine.

[7]  Xavier Crevoisier,et al.  Quantitative estimation of foot-flat and stance phase of gait using foot-worn inertial sensors. , 2013, Gait & posture.

[8]  Jin-Shin Lai,et al.  A pelvic motion driven electrical stimulator for drop-foot treatment , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  Kevin M. Foglyano,et al.  Development of a self-contained accelerometry based system for control of functional electrical stimulation in hemiplegia , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  E. Marsolais,et al.  Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation , 1994 .

[11]  T. Johnston,et al.  Implantable FES system for upright mobility and bladder and bowel function for individuals with spinal cord injury , 2005, Spinal Cord.

[12]  B. Smith,et al.  In-line lead connector for use with implanted neuroprosthesis , 1991, IEEE Transactions on Biomedical Engineering.

[13]  Bernard Espiau,et al.  Detection of Freezing of Gait in Parkinson Disease: Preliminary Results , 2014, Sensors.

[14]  E. Marsolais,et al.  Implanted functional electrical stimulation system for mobility in paraplegia: a follow-up case report. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[15]  G. Lyons,et al.  The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking. , 2003, Medical engineering & physics.

[16]  D Kotiadis,et al.  Inertial Gait Phase Detection for control of a drop foot stimulator Inertial sensing for gait phase detection. , 2010, Medical engineering & physics.

[17]  D. Guiraud,et al.  An implantable neuroprosthesis for standing and walking in paraplegia: 5-year patient follow-up , 2006, Journal of neural engineering.

[18]  Ciara M O'Connor,et al.  Automatic detection of gait events using kinematic data. , 2007, Gait & posture.

[19]  R. Kobetic,et al.  Walking after incomplete spinal cord injury using an implanted FES system: a case report. , 2007, Journal of rehabilitation research and development.

[20]  M. Hanlon,et al.  Real-time gait event detection using wearable sensors. , 2006, Gait & posture.

[21]  Peter H Veltink,et al.  Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems. , 2002, Journal of biomechanics.

[22]  Sungjae Hwang,et al.  Novel algorithm for the hemiplegic gait evaluation using a single 3-axis accelerometer , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[23]  R. Kobetic,et al.  Neurotherapeutic and neuroprosthetic effects of implanted functional electrical stimulation for ambulation after incomplete spinal cord injury. , 2010, Journal of rehabilitation research and development.

[24]  Michael W. Keith,et al.  A surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation system , 1994 .

[25]  J. Norton,et al.  Clinical use of the Odstock dropped foot stimulator: its effect on the speed and effort of walking. , 1999, Archives of physical medicine and rehabilitation.

[26]  Brian J Hafner,et al.  Effect of a Foot-Drop Stimulator and Ankle–Foot Orthosis on Walking Performance After Stroke , 2013, Neurorehabilitation and neural repair.

[27]  Yoichi Shimada,et al.  Clinical application of acceleration sensor to detect the swing phase of stroke gait in functional electrical stimulation. , 2005, The Tohoku journal of experimental medicine.

[28]  E. Condie,et al.  Functional Electrical Stimulation: Standing and Walking After Spinal Cord Injury , 1990 .

[29]  P. Veltink,et al.  The Sensitivity and Selectivity of an Implantable Two‐Channel Peroneal Nerve Stimulator System for Restoration of Dropped Foot , 2002, Neuromodulation : journal of the International Neuromodulation Society.

[30]  T. Bajd,et al.  Multichannel electrical stimulation for correction of hemiplegic gait. Methodology and preliminary results. , 1978, Scandinavian journal of rehabilitation medicine.

[31]  T. Sinkjaer,et al.  A review of portable FES-based neural orthoses for the correction of drop foot , 2002, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[32]  A. Esquenazi,et al.  The ReWalk Powered Exoskeleton to Restore Ambulatory Function to Individuals with Thoracic-Level Motor-Complete Spinal Cord Injury , 2012, American journal of physical medicine & rehabilitation.

[33]  A. Wolf,et al.  Effects of Dual-Channel Functional Electrical Stimulation on Gait Performance in Patients with Hemiparesis , 2012, TheScientificWorldJournal.