C-Arm Conebeam CT Perfusion Imaging in the Angiographic Suite: A Comparison with Multidetector CT Perfusion Imaging

BACKGROUND AND PURPOSE: Perfusion imaging in the angiography suite may provide a way to reduce time from stroke onset to endovascular revascularization of patients with large-vessel occlusion. Our purpose was to compare conebeam CT perfusion with multidetector CT perfusion. MATERIALS AND METHODS: Data from 7 subjects with both multidetector CT perfusion and conebeam CT perfusion were retrospectively processed and analyzed. Two algorithms were used to enhance temporal resolution and temporal sampling density and reduce the noise of conebeam CT data before generating perfusion maps. Two readers performed qualitative image-quality evaluation on maps by using a 5-point scale. ROIs indicating CBF/CBV abnormalities were drawn. Quantitative analyses were performed by using the Sørensen-Dice coefficients to quantify the similarity of abnormalities. A noninferiority hypothesis was tested to compare conebeam CT perfusion against multidetector CT perfusion. RESULTS: Average image-quality scores for multidetector CT perfusion and conebeam CT perfusion images were 2.4 and 2.3, respectively. The average confidence score in diagnosis was 1.4 for both multidetector CT and conebeam CT; the average confidence scores for the presence of a CBV/CBF mismatch were 1.7 (κ = 0.50) and 1.5 (κ = 0.64). For multidetector CT perfusion and conebeam CT perfusion maps, the average scores of confidence in making treatment decisions were 1.4 (κ = 0.79) and 1.3 (κ = 0.90). The area under the visual grading characteristic for the above 4 qualitative quality scores showed an average area under visual grading characteristic of 0.50, with 95% confidence level cover centered at the mean for both readers. The Sørensen–Dice coefficient for CBF maps was 0.81, and for CBV maps, 0.55. CONCLUSIONS: After postprocessing methods were applied to enhance image quality for conebeam CT perfusion maps, the conebeam CT perfusion maps were not inferior to those generated from multidetector CT perfusion.

[1]  A. Demchuk,et al.  Thrombectomy within 8 hours after symptom onset in ischemic stroke. , 2015, The New England journal of medicine.

[2]  Wan-Yuo Guo,et al.  Toward the Era of a One-Stop Imaging Service Using an Angiography Suite for Neurovascular Disorders , 2013, BioMed research international.

[3]  M. Manhart,et al.  C-Arm CT Measurement of Cerebral Blood Volume and Cerebral Blood Flow Using a Novel High-Speed Acquisition and a Single Intravenous Contrast Injection , 2013, American Journal of Neuroradiology.

[4]  A. Bonafe,et al.  Optimal Workflow and Process-Based Performance Measures for Endovascular Therapy in Acute Ischemic Stroke: Analysis of the Solitaire FR Thrombectomy for Acute Revascularization Study , 2014, Stroke.

[5]  Kai Niu,et al.  A novel temporal recovery technique to enable cone beam CT perfusion imaging using an interventional C-arm system , 2013, Medical Imaging.

[6]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[7]  Michael D Hill,et al.  Endovascular therapy after intravenous t-PA versus t-PA alone for stroke. , 2013, The New England journal of medicine.

[8]  Hester F. Lingsma,et al.  A randomized trial of intraarterial treatment for acute ischemic stroke. , 2015, The New England journal of medicine.

[9]  M. Krause,et al.  Endovascular therapy for ischemic stroke with perfusion-imaging selection. , 2015, The New England journal of medicine.

[10]  PhD A. Doerfler MD,et al.  Flat-Panel Computed Tomography (DYNA-CT) in Neuroradiology. From High-Resolution Imaging of Implants to One-Stop-Shopping for Acute Stroke , 2015, Clinical Neuroradiology.

[11]  F. Sallustio,et al.  Thrombectomy within 8 hours after symptom onset in ischemic stroke , 2015 .

[12]  Michael D Hill,et al.  Time to angiographic reperfusion and clinical outcome after acute ischaemic stroke: an analysis of data from the Interventional Management of Stroke (IMS III) phase 3 trial , 2014, The Lancet Neurology.

[13]  Bram van Ginneken,et al.  Quantitative Dose Dependency Analysis of Whole-Brain CT Perfusion Imaging. , 2016, Radiology.

[14]  Kai Niu,et al.  Radiation dose reduction and CNR enhancement in C-arm cone beam CT , 2013, Medical Imaging.

[15]  André Aichert,et al.  Denoising and artefact reduction in dynamic flat detector CT perfusion imaging using high speed acquisition: first experimental and clinical results , 2014, Physics in medicine and biology.

[16]  H. Diener,et al.  Stent-retriever thrombectomy after intravenous t-PA vs. t-PA alone in stroke. , 2015, The New England journal of medicine.

[17]  T Struffert,et al.  Dynamic Angiography and Perfusion Imaging Using Flat Detector CT in the Angiography Suite: A Pilot Study in Patients with Acute Middle Cerebral Artery Occlusions , 2015, American Journal of Neuroradiology.

[18]  Eric E. Smith,et al.  Randomized assessment of rapid endovascular treatment of ischemic stroke. , 2015, The New England journal of medicine.