Cavity ringdown spectroscopic detection of nitric oxide with a continuous-wave quantum-cascade laser.

A spectroscopic gas sensor for nitric oxide (NO) detection based on a cavity ringdown technique was designed and evaluated. A cw quantum-cascade distributed-feedback laser operating at 5.2 mum was used as a tunable single-frequency light source. Both laser-frequency tuning and abrupt interruptions of the laser radiation were performed through manipulation of the laser current. A single ringdown event sensitivity to absorption of 2.2 x 10(-8) cm(-1) was achieved. Measurements of parts per billion (ppb) NO concentrations in N(2) with a 0.7-ppb standard error for a data collection time of 8 s have been performed. Future improvements are discussed that would allow quantification of NO in human breath.

[1]  Mattias Beck,et al.  Continuous wave operation of a 9.3 μm quantum cascade laser on a Peltier cooler , 2001 .

[2]  A. Cho,et al.  Effective utilization of quantum-cascade distributed-feedback lasers in absorption spectroscopy. , 2000, Applied optics.

[3]  Mattias Beck,et al.  High-temperature operation of distributed feedback quantum-cascade lasers at 5.3 μm , 2001 .

[4]  Kenneth W. Busch,et al.  Cavity-ringdown spectroscopy : an ultratrace-absorption measurement technique , 1999 .

[5]  A. O’Keefe,et al.  Cavity ring‐down optical spectrometer for absorption measurements using pulsed laser sources , 1988 .

[6]  M. Mürtz,et al.  High-resolution cavity leak-out absorption spectroscopy in the 10-μm region , 1999 .

[7]  Yabai He,et al.  Ringdown and cavity-enhanced absorption spectroscopy using a continuous-wave tunable diode laser and a rapidly swept optical cavity , 2000 .

[8]  G. Berden,et al.  Cavity ring-down spectroscopy: Experimental schemes and applications , 2000 .

[9]  N. Wilson,et al.  Inflammatory markers in clinical practice. , 2000, American journal of respiratory and critical care medicine.

[10]  A A Kosterev,et al.  Trace-gas detection in ambient air with a thermoelectrically cooled, pulsed quantum-cascade distributed feedback laser. , 2000, Applied optics.

[11]  Charles C. Harb,et al.  A laser-locked cavity ring-down spectrometer employing an analog detection scheme , 2000 .

[12]  D. Romanini,et al.  CW cavity ring down spectroscopy , 1997 .

[13]  K. Booth No news is good news--or is it? , 1991, Australian dental practice.

[14]  A. Cho,et al.  Spectroscopic detection of biological NO with a quantum cascade laser , 2001, Applied physics. B, Lasers and optics.

[15]  Claire F. Gmachl,et al.  Mid-infrared tunable quantum cascade lasers for gas-sensing applications , 2000 .

[16]  J. B. Paul,et al.  Cavity Ringdown Laser Absorption Spectroscopy: History, Development, and Application to Pulsed Molecular Beams. , 1997, Chemical reviews.

[17]  B. Lipworth,et al.  Antiasthmatic effects of mediator blockade versus topical corticosteroids in allergic rhinitis and asthma. , 2000, American journal of respiratory and critical care medicine.

[18]  A. Hall Applied Optics. , 2022, Science.

[19]  A. Cho,et al.  High-resolution (Doppler-limited) spectroscopy using quantum-cascade distributed-feedback lasers. , 1998, Optics letters.

[20]  F. Capasso,et al.  New frontiers in quantum cascade lasers and applications , 2000, IEEE Journal of Selected Topics in Quantum Electronics.

[21]  Rudy Peeters,et al.  Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopy , 1998 .

[22]  R N Zare,et al.  Frequency-switched heterodyne cavity ringdown spectroscopy. , 2000, Optics letters.

[23]  Laurence S. Rothman,et al.  Reprint of: The HITRAN molecular spectroscopic database and HAWKS (HITRAN Atmospheric Workstation): 1996 edition , 1998 .

[24]  R. Zare,et al.  Cavity ringdown spectroscopy using mid-infrared quantum-cascade lasers. , 2000, Optics letters.

[25]  M. Phillips,et al.  Breath tests in medicine. , 1992, Scientific American.